Investigation of Reduced Susceptibility to Glycopeptides among Methicillin-Resistant Staphylococcus aureus Isolates from Patients in Ireland and Evaluation of Agar Screening Methods for Detection of Heterogeneously Glycopeptide-Intermediate S. aureus
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) isolates ( n = 3,189) from 2,990 patients were investigated by agar screening and by the Etest macromethod for reduced susceptibility to glycopeptide. No vancomycin-resistant S. aureus or glycopeptide-intermediate S. aureus (GISA) isolates were detected, but 178 isolates were confirmed as hetero-GISA (hGISA) by vancomycin population analysis profile (vPAP)-area under the curve (AUC) ratio determination and/or teicoplanin PAP (tPAP) methods. Of 139 isolates detected using the recommended Etest macromethod cutoff values of ≥8 mg/liter for both vancomycin and teicoplanin or ≥12 mg/liter for teicoplanin alone, 73 were confirmed as hGISA by vPAP-AUC, 95 were confirmed as hGISA by tPAP, and 108 were confirmed as hGISA by both methods. An Etest macromethod cutoff value of 8 mg/liter for teicoplanin alone detected a further 70 hGISA (17 were confirmed by vPAP-AUC and 70 were confirmed by tPAP). Agar screening utilizing brain heart infusion (BHI) agar containing 6 mg of vancomycin/liter (BHIV6) and Mueller-Hinton (MH) agar containing 8 mg of teicoplanin/liter (MHT8) failed to detect hGISA. MH agar containing 5 mg of teicoplanin/liter (MHT5) and BHI containing 5 mg of teicoplanin/liter (BHIT5) were evaluated using 10-μl volumes of three inoculum concentrations (with densities equivalent to 0.5 and 2.0 McFarland turbidity standards and stationary-phase BHI broth subcultures [MHT5 0.5 , MHT5 2.0 , MHT5 S , BHIT5 0.5 , BHIT5 2.0 , and BHIT5 S ]). The sensitivity of all methods except MHT5 0.5 and MHT5 2.0 was 100%. The specificity ranged from 4 to 82%. BHIT5 0.5 yielded the best performance, with a specificity of 84% for detecting isolates with teicoplanin Etest macromethod values of ≥8 mg/liter. Screening on BHIT5 0.5 is useful where screen-positive isolates are investigated with the Etest macromethod and confirmed by vPAP-AUC and tPAP. The prevalence of hGISA among patients with blood culture isolates recovered in Irish hospitals between 1999 and 2003 was 2.6%, whereas the prevalence among patients with isolates from all specimen sites collected during a 2-week survey in 1999 was 12%. The prevalence in one hospital decreased from 5.3% in 2003 to 1.5% in 2004.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wootton, M. (2001) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/47.4.399 · Cited by 414 · cited 5×
“29 and/or a tPAP with a resistant subpopulation growing at concentrations 8 mg of teicoplanin/liter (18, 29).”
BackgroundInfluentialHowden, B. P., Johnson, P. D. R., Ward, P. B., Stinear, T. P., & Davies, J. K. (2006) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00422-06 · Cited by 224
Cited by
Howden, B. P., Davies, J. K., Johnson, P. D. R., Stinear, T. P., & Grayson, M. L. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00042-09 · Cited by 962
“5-McFarland-standard suspension, a 2-McFarland-standard suspension, and a BHIB stationary-phase culture (82).”
BackgroundShariati, A., Dadashi, M., Moghadam, M. T., van Belkum, A., Yaslianifard, S., & Darban-Sarokhalil, D. (2020) · Scientific Reports · doi:10.1038/s41598-020-69058-z · Cited by 329
van Hal, S. J., & Paterson, D. L. (2011) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01133-10 · Cited by 165
Bae, I., Federspiel, J. J., Miró, J. M., Woods, C. W., Park, L., Rybak, M. J., Rude, T. H., Bradley, S., Bukovski, S., de la Maria, C. G., et al. (2009) · The Journal of Infectious Diseases · doi:10.1086/606027 · Cited by 122
Egyir, B., Guardabassi, L., Sørum, M., Nielsen, S. S., Kolekang, A., Frimpong, E., Addo, K. K., Newman, M. J., & Larsen, A. R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089716 · Cited by 108
“Brain Heart Infusion agar supplemented with teicoplanin (5 mg/L) (Becton Dickinson, Denmark) was used to screen MRSA isolates for glycopeptides resistance by a spot test; if 10 or more colonies were detected on these plates, E-tests (bioMérieux, Marcy I’Etoile, France) were used to determine the minimum inhibitory con…”
MethodZhang, S., Sun, X., Chang, W., Dai, Y., & Ma, X. (2015) · PLOS ONE · doi:10.1371/journal.pone.0136082 · Cited by 99
Metadata
- Authors
- Fitzgibbon, M. M., Rossney, A. S., & O'Connell, B.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2007-10
- Volume
- 45
- Issue
- 10
- Pages
- 3263-3269
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2119884936
- Cited by
- 37
- References
- 2
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.