Cited by 37

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Methicillin-resistant Staphylococcus aureus (MRSA) isolates ( n = 3,189) from 2,990 patients were investigated by agar screening and by the Etest macromethod for reduced susceptibility to glycopeptide. No vancomycin-resistant S. aureus or glycopeptide-intermediate S. aureus (GISA) isolates were detected, but 178 isolates were confirmed as hetero-GISA (hGISA) by vancomycin population analysis profile (vPAP)-area under the curve (AUC) ratio determination and/or teicoplanin PAP (tPAP) methods. Of 139 isolates detected using the recommended Etest macromethod cutoff values of ≥8 mg/liter for both vancomycin and teicoplanin or ≥12 mg/liter for teicoplanin alone, 73 were confirmed as hGISA by vPAP-AUC, 95 were confirmed as hGISA by tPAP, and 108 were confirmed as hGISA by both methods. An Etest macromethod cutoff value of 8 mg/liter for teicoplanin alone detected a further 70 hGISA (17 were confirmed by vPAP-AUC and 70 were confirmed by tPAP). Agar screening utilizing brain heart infusion (BHI) agar containing 6 mg of vancomycin/liter (BHIV6) and Mueller-Hinton (MH) agar containing 8 mg of teicoplanin/liter (MHT8) failed to detect hGISA. MH agar containing 5 mg of teicoplanin/liter (MHT5) and BHI containing 5 mg of teicoplanin/liter (BHIT5) were evaluated using 10-μl volumes of three inoculum concentrations (with densities equivalent to 0.5 and 2.0 McFarland turbidity standards and stationary-phase BHI broth subcultures [MHT5 0.5 , MHT5 2.0 , MHT5 S , BHIT5 0.5 , BHIT5 2.0 , and BHIT5 S ]). The sensitivity of all methods except MHT5 0.5 and MHT5 2.0 was 100%. The specificity ranged from 4 to 82%. BHIT5 0.5 yielded the best performance, with a specificity of 84% for detecting isolates with teicoplanin Etest macromethod values of ≥8 mg/liter. Screening on BHIT5 0.5 is useful where screen-positive isolates are investigated with the Etest macromethod and confirmed by vPAP-AUC and tPAP. The prevalence of hGISA among patients with blood culture isolates recovered in Irish hospitals between 1999 and 2003 was 2.6%, whereas the prevalence among patients with isolates from all specimen sites collected during a 2-week survey in 1999 was 12%. The prevalence in one hospital decreased from 5.3% in 2003 to 1.5% in 2004.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.00836-07

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 37

Metadata

Authors
Fitzgibbon, M. M., Rossney, A. S., & O'Connell, B.
Venue
Journal of Clinical Microbiology
Published
2007-10
Volume
45
Issue
10
Pages
3263-3269
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2119884936
Cited by
37
References
2
FWCI
2.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.