Multicenter Comparison of Different Real-Time PCR Assays for Quantitative Detection of Epstein-Barr Virus
Open accessThe DOI matches its Crossref record.
Abstract
Quantification of Epstein-Barr virus (EBV) in peripheral blood is important for the diagnosis and management of serious EBV diseases, including posttransplant lymphoproliferative disorder. A variety of PCR-based methods are currently in use; however, there is little information on their comparability. This study assessed the relative performance of different quantitative assays. A multicenter comparative study was performed at eight sites using three panels consisting of serial dilutions of quantified EBV DNA and extracts from a total of 19 whole-blood specimens. Samples were distributed and tested blindly. Instrumentation, probe chemistries, amplification targets, and other test-related aspects varied considerably between laboratories. Each laboratory's calibration curve indicated strong evidence of a consistent log-linear relationship between viral load and cycle threshold, suggesting that intralaboratory tracking of a given patient would yield similar relative quantitative trends among the participating test sites. There was strong concordance among laboratories with respect to qualitative test results; however, marked quantitative discordance was seen. For most samples, the across-laboratory interquartile range of the reported viral load (in copies/μl) was roughly 0.6 log-units, and for one sample the overall range was approximately 4.2 log-units. While intralaboratory tracking of patients may yield similar results, these data indicate a need for caution when attempting to compare clinical results obtained at different institutions and suggest the potential value to be gained by more standardized testing methodology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Ultimate qPCR Experiment: Producing Publication Quality, Reproducible Data the First Time
Taylor, S. C., Nadeau, K., Abbasi, M., Lachance, C., Nguyen, M., & Fenrich, J. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.12.002 · Cited by 830
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Progress and Problems in Understanding and Managing Primary Epstein-Barr Virus Infections
Odumade, O. A., Hogquist, K. A., & Balfour, H. H. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00044-10 · Cited by 458
Self-citationWhy the need for qPCR publication guidelines?—The case for MIQE
Bustin, S. A. (2010) · Methods · doi:10.1016/j.ymeth.2009.12.006 · Cited by 375
Allen, U. D., Preiksaitis, J. K., & Practice, T. A. I. D. C. O. (2019) · Clinical Transplantation · doi:10.1111/ctr.13652 · Cited by 375
Metadata
- Authors
- Hayden, R. T., Hokanson, K. M., Pounds, S. B., Bankowski, M. J., Belzer, S. W., Carr, J., Diorio, D., Forman, M. S., Joshi, Y., Hillyard, D., Hodinka, R. L., Nikiforova, M. N., Romain, C. A., Stevenson, J., Valsamakis, A., & Balfour, H. H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2008-01
- Volume
- 46
- Issue
- 1
- Pages
- 157-163
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2100348181
- Cited by
- 138
- References
- 0
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicenter Comparison of Different Real-Time PCR Assays for Quantitative Detection of Epstein-Barr Virus. https://app.cochat.ai/papers/10.1128/jcm.01252-07
- The paper
- Hayden, R. T., Hokanson, K. M., Pounds, S. B., Bankowski, M. J., Belzer, S. W., Carr, J., Diorio, D., Forman, M. S., Joshi, Y., Hillyard, D., Hodinka, R. L., Nikiforova, M. N., Romain, C. A., Stevenson, J., Valsamakis, A., & Balfour, H. H. (2008). Multicenter Comparison of Different Real-Time PCR Assays for Quantitative Detection of Epstein-Barr Virus. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.01252-07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.