The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Real-Time Identification of Bacteria and Candida Species in Positive Blood Culture Broths by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry
Open accessAbstract
Delays in the identification of microorganisms are a barrier to the establishment of adequate empirical antibiotic therapy of bacteremia. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS) allows the identification of microorganisms directly from colonies within minutes. In this study, we have adapted and tested this technology for use with blood culture broths, thus allowing identification in less than 30 min once the blood culture is detected as positive. Our method is based on the selective recovery of bacteria by adding a detergent that solubilizes blood cells but not microbial membranes. Microorganisms are then extracted by centrifugation and analyzed by MALDI-TOF-MS. This strategy was first tested by inoculating various bacterial and fungal species into negative blood culture bottles. We then tested positive patient blood or fluid samples grown in blood culture bottles, and the results obtained by MALDI-TOF-MS were compared with those obtained using conventional strategies. Three hundred twelve spiked bottles and 434 positive cultures from patients were analyzed. Among monomicrobial fluids, MALDI-TOF-MS allowed a reliable identification at the species, group, and genus/family level in 91%, 5%, and 2% of cases, respectively, in 20 min. In only 2% of these samples, MALDI-TOF MS did not yield any result. When blood cultures were multibacterial, identification was improved by using specific databases based on the Gram staining results. MALDI-TOF-MS is currently the fastest technique to accurately identify microorganisms grown in positive blood culture broths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D. (2009) · Clinical Infectious Diseases · doi:10.1086/600885 · Cited by 1,983 · cited 1×
“Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF–MS) allows rapid identification of bacteria grown on solid media by the identification of species-specific profiles obtained from isolated colonies (3, 5, 25).”
BackgroundIbrahim, E. H., Sherman, G., Ward, S., Fraser, V. J., & Kollef, M. H. (2000) · Chest · doi:10.1378/chest.118.1.146 · Cited by 1,779
Harbarth, S., Garbino, J., Pugin, J., Romand, J. A., Lew, D., & Pittet, D. (2003) · The American Journal of Medicine · doi:10.1016/j.amjmed.2003.07.005 · Cited by 637
Stevenson, L. G., Drake, S. K., & Murray, P. R. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.01541-09 · Cited by 424
Fluorescent In Situ Hybridization Allows Rapid Identification of Microorganisms in Blood Cultures
Kempf, V. A. J., Trebesius, K., & Autenrieth, I. B. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.2.830-838.2000 · Cited by 405
Clinical impact of rapid in vitro susceptibility testing and bacterial identification
Doern, G. V., Vautour, R., Gaudet, M., & Levy, B. (1994) · Journal of Clinical Microbiology · doi:10.1128/jcm.32.7.1757-1762.1994 · Cited by 385
La Scola, B., & Raoult, D. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008041 · Cited by 383
Barenfanger, J., Drake, C., & Kacich, G. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.5.1415-1418.1999 · Cited by 370
Carbonnelle, E., Beretti, J.-L., Cottyn, S., Quesne, G., Berche, P., Nassif, X., & Ferroni, A. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02405-06 · Cited by 242
Self-citationDegand, N., Carbonnelle, E., Dauphin, B., Beretti, J.-L., Le Bourgeois, M., Sermet-Gaudelus, I., Segonds, C., Berche, P., Nassif, X., & Ferroni, A. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00569-08 · Cited by 231
Self-citationKerremans, J. J., Verboom, P., Stijnen, T., Hakkaart-van Roijen, L., Goessens, W., Verbrugh, H. A., & Vos, M. C. (2007) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkm497 · Cited by 224
Ling, T. K. W., Liu, Z. K., & Cheng, A. F. B. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.10.4705-4707.2003 · Cited by 177
Rigby, S., Procop, G. W., Haase, G., Wilson, D., Hall, G., Kurtzman, C., Oliveira, K., Von Oy, S., Hyldig-Nielsen, J. J., Coull, J., et al. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.6.2182-2186.2002 · Cited by 159
de Cueto, M., Ceballos, E., Martínez-Martínez, L., Perea, E. J., & Pascual, Á. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.8.3734-3738.2004 · Cited by 122
Peters, R. P. H., Savelkoul, P. H. M., Simoons-Smit, A. M., Danner, S. A., Vandenbroucke‐Grauls, C. M. J. E., & van Agtmael, M. A. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.44.1.119-123.2006 · Cited by 95
Utility of Pyrosequencing in Identifying Bacteria Directly from Positive Blood Culture Bottles
Jordan, J. A., Jones-Laughner, J., & Durso, M. B. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.01991-08 · Cited by 75
Ruimy, R., Dos-Santos, M., Raskine, L., Bert, F., Masson, R., Elbaz, S., Bonnal, C., Lucet, J., Lefort, A., Fantin, B., et al. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.02250-07 · Cited by 63
Søgaard, M., Stender, H., & Schønheyder, H. C. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.4.1947-1949.2005 · Cited by 59
Parta, M., Goebel, M. C., Matloobi, M., Stager, C. E., & Musher, D. M. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.00351-09 · Cited by 54
Gröbner, S., Dion, M., Plante, M., & Kempf, V. A. J. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.02179-08 · Cited by 54
Cited by
Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology
Croxatto, A., Prod'hom, G., & Greub, G. (2012) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2011.00298.x · Cited by 997
Sepsis: a roadmap for future research
Cohen, J., Vincent, J.-L., Adhikari, N. K. J., Machado, F. R., Angus, D. C., Calandra, T., Jaton, K., Giulieri, S., Delaloye, J., Opal, S., et al. (2015) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(15)70112-x · Cited by 992
Clark, A. E., Kaleta, E. J., Arora, A., & Wolk, D. M. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00072-12 · Cited by 941
Wieser, A., Schneider, L., Jung, J., & Schubert, S. (2012) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3783-4 · Cited by 453
MALDI-TOF mass spectrometry tools for bacterial identification in clinical microbiology laboratory
Carbonnelle, E., Mesquita, C., Bille, E., Day, N., Dauphin, B., Beretti, J.-L., Ferroni, A., Gutmann, L., & Nassif, X. (2011) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.06.017 · Cited by 420
Self-citation
Metadata
- Authors
- Ferroni, A., Suarez, S., Beretti, J.-L., Dauphin, B., Bille, E., Meyer, J., Bougnoux, M.-E., Alanio, A., Berche, P., & Nassif, X.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2010-05
- Volume
- 48
- Issue
- 5
- Pages
- 1542-1548
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2158399071
- Cited by
- 283
- References
- 20
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.