Examination of the morphology of bacteria adhering to peritoneal dialysis catheters by scanning and transmission electron microscopy
Open accessThe DOI matches its Crossref record.
Abstract
We examined Tenckhoff peritoneal catheters by scanning and transmission electron microscopy to study the morphology of bacterial adherence. Two catheters were removed from uninfected patients, three from patients with exit site infections, four from patients with peritonitis, and one from a patient with both exit site infection and peritonitis. Infecting organisms included three of Staphylococcus aureus and one each of Enterobacter sp., Staphylococcus epidermidis, Achromobacter xylosoxidans, Serratia sp., Klebsiella sp., and Candida albicans. Considerable morphological variation in adherence to the peritoneal dialysis apparatus occurred. No inflammatory cells were ever seen in association with infected cuffs, only two of the five patients with peritonitis had inflammatory cells associated with their catheters. In both instances, these cells tended to occur in clumps and demonstrated no flattening when in contact with the surface. Colonization of the catheter was uneven--bacteria tended to occur in clusters. Extensive matrix formation was evident in several instances, and condensation of this matrix onto the bacteria during the dehydration process rendered clumps of bacterial cells amorphous at times. Bacteria were adherent to the subcutaneous cuff in those patients with exit site infections. Gram-negative bacteria attached to individual dacron fibers of the cuff, often several layers deep. Gram-positive bacteria tended to adhere in clusters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bacterial Biofilms in Nature and Disease
Costerton, J. W., Cheng, K. J., Geesey, G. G., Ladd, T. I., Nickel, J. C., Dasgupta, M., & Marrie, T. J. (1987) · Annual Review of Microbiology · doi:10.1146/annurev.mi.41.100187.002251 · Cited by 3,145
Self-citationChristensen, G. D., Simpson, W. A., Younger, J. J., Baddour, L. M., Barrett, F. F., Melton, D. M., & Beachey, E. H. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.22.6.996-1006.1985 · Cited by 2,255
The role of bacterial biofilms in chronic infections
Bjarnsholt, T. (2013) · APMIS · doi:10.1111/apm.12099 · Cited by 1,080
Nickel, J. C., Ruseska, I., Wright, J. B., & Costerton, J. W. (1985) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.27.4.619 · Cited by 889
Self-citationBjarnsholt, T., Alhede, M., Alhede, M., Eickhardt-Sørensen, S. R., Moser, C., Kühl, M., Jensen, P. Ø., & Høiby, N. (2013) · Trends in Microbiology · doi:10.1016/j.tim.2013.06.002 · Cited by 764
ESCMID∗ guideline for the diagnosis and treatment of biofilm infections 2014
Høiby, N., Bjarnsholt, T., Moser, C., Bassi, G. L., Coenye, T., Donelli, G., Hall-Stoodley, L., Holá, V., Imbert, C., Kirketerp-Møller, K., et al. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2014.10.024 · Cited by 726
Bacterial resistance to antibiotics: The role of biofilms
Hoyle, B. D., & Costerton, J. W. (1991) · Progress in Drug Research / Fortschritte der Arzneimittelforschung / Progrès des recherches pharmaceutiques · doi:10.1007/978-3-0348-7139-6_2 · Cited by 449
Self-citationDavenport, D. S., Massanari, R. M., Pfaller, M. A., Bale, M. J., Streed, S. A., & Hierholzer, W. J. (1986) · Journal of Infectious Diseases · doi:10.1093/infdis/153.2.332 · Cited by 227
“Transmission and scanning electron micrographs have shown that slimepositive strains, in contrast to slime-negative strains, are encased in an extracellular matrix [30, 34-39].”
BackgroundPseudomonas aeruginosa Biofilms
Alhede, M., Bjarnsholt, T., Givskov, M., & Alhede, M. (2014) · Advances in Applied Microbiology · doi:10.1016/b978-0-12-800262-9.00001-9 · Cited by 225
Pathogenesis of infections related to intravascular catheterization
Goldmann, D. A., & Pier, G. B. (1993) · Clinical Microbiology Reviews · doi:10.1128/cmr.6.2.176 · Cited by 218
“Exuberant biofilm formation has also been seen on infected cardiac pacemaker leads and power packs (121) and on peritoneal dialysis catheters (123).”
BackgroundEvaluation of different detection methods of biofilm formation in Staphylococcus aureus
Knobloch, J., Horstkotte, M., Rohde, H., & Mack, D. (2002) · Medical Microbiology and Immunology · doi:10.1007/s00430-002-0124-3 · Cited by 202
Younger, J. J., Christensen, G. D., Bartleyt, D. L., Simmons, J. C. H., & Barrett, F. F. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.4.548 · Cited by 187
“with a variety of in vitro, in vivo, and epidemiological studies regarding coagulase-negative staphylococci and intravascular catheters [6,19-24], peritoneal dialysis catheters [25,26], and pacemakers [Z7, 28].”
BackgroundBiliary Stent Blockage with Bacterial Biofilm: A Light and Electron Microscopy Study
SPEER, A. G., COTTON, P. B., RODE, J., SEDDON, A. M., NEAL, C. R., HOLTON, J., & COSTERTON, J. W. (1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-4-546 · Cited by 186
Self-citationWang, A. Y. M., Yu, A. W. Y., Li, P. K. T., Lam, P. K. W., Leung, C. B., Lai, K. N., & Lui, S. F. (2000) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2000.19833 · Cited by 186
Biofilm-related infections in ophthalmology
Elder, M. J., Stapleton, F., Evans, E., & Dart, J. K. G. (1995) · Eye · doi:10.1038/eye.1995.16 · Cited by 174
The slime of coagulase-negative staphylococci: Biochemistry and relation to adherence
Hussain, M. (1993) · FEMS Microbiology Letters · doi:10.1016/0378-1097(93)90596-t · Cited by 173
Modulation of adherence of coagulase-negative staphylococci to teflon catheters in vitro
Pascual, A., Fleer, A., Westerdaal, N. A. C., & Verhoef, J. (1986) · European Journal of Clinical Microbiology · doi:10.1007/bf02017694 · Cited by 161
“A similar material was often found' to be present on catheters recovered from patients (8, 9).”
BackgroundHydrophobic polycationic coatings that inhibit biofilms and support bone healing during infection
Schaer, T. P., Stewart, S., Hsu, B. B., & Klibanov, A. M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.038 · Cited by 160
“4d displayed thick carpets of sessile bacteria covered by extracellular matrix that appears similar to the exopolysaccharide matrix described in the literature [43].”
BackgroundPhenotypic variation of Staphylococcus epidermidis slime production in vitro and in vivo
Christensen, G. D., Baddour, L. M., & Simpson, W. A. (1987) · Infection and Immunity · doi:10.1128/iai.55.12.2870-2877.1987 · Cited by 159
“peritoneal dialysis catheters (4, 30) have found thick coats of adherent cocci caked in amorphous materials.”
BackgroundUltrastructural study of microbiologic colonization of urinary catheters
Curtis Nickel, J., Downey, J. A., & William Costerton, J. (1989) · Urology · doi:10.1016/0090-4295(89)90327-0 · Cited by 43
Metadata
- Authors
- Marrie, T. J., Noble, M. A., & Costerton, J. W.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1983-12
- Volume
- 18
- Issue
- 6
- Pages
- 1388-1398
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1586020115
- Cited by
- 138
- References
- 0
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.