Association of slime with pathogenicity of coagulase-negative staphylococci causing nosocomial septicemia
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
To assess the role of slime in the pathogenesis of nosocomial bloodstream infections caused by coagulase-negative staphylococci, we compared the characteristics of 27 nosocomial bloodstream isolates with those of 27 skin isolates from non-hospital personnel. Of 27 bloodstream isolates, 14 were judged to be significant by a clinical index, and 13 were contaminants. Slime production was observed in 13 of 14 significant isolates but in only 3 of 13 contaminants (P = 0.0003) and 4 of 27 skin isolates (P = 0.0001). The 14 pathogens were identified as Staphylococcus epidermidis. Only 7 of 13 contaminants and 9 of 27 skin isolates belonged to the same species (P less than 0.006). Slime-producing strains of S. epidermidis represented 13 of 14 pathogens but only 2 of 13 contaminants (P less than 0.0003). Neither adherence to Teflon catheters nor phagocytosis and killing of coagulase-negative staphylococci by polymorphonuclear leukocytes was significantly influenced by slime production. Nevertheless, the identity of the organism and the slime production test predicted the clinical significance of blood isolates of coagulase-negative staphylococci with an overall accuracy of 89%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces
Christensen, G. D., Simpson, W. A., Bisno, A. L., & Beachey, E. H. (1982) · Infection and Immunity · doi:10.1128/iai.37.1.318-326.1982 · Cited by 1,410 · cited 7×
“328, 1984) and in clinical studies (3, 5).”
BackgroundInfluentialPathogenesis of Foreign Body Infection: Description and Characteristics of an Animal Model
Zimmerli, W., Waldvogel, F. A., Vaudaux, P., & Nydegger, U. E. (1982) · Journal of Infectious Diseases · doi:10.1093/infdis/146.4.487 · Cited by 630 · cited 1×
“Alternatively, slime-producing organisms may escape phagocytosis only in the presence of a foreign body (6, 38, 39).”
BackgroundAdherence and Growth of Coagulase-Negative Staphylococci on Surfaces of Intravenous Catheters
Peters, G., Locci, R., & Pulverer, G. (1982) · Journal of Infectious Diseases · doi:10.1093/infdis/146.4.479 · Cited by 559 · cited 2×
“It has also been suggested that the organisms can multiply on the catheter surface even in the absence of nutrients in the surrounding medium (31).”
BackgroundPathogenesis of foreign body infection. Evidence for a local granulocyte defect.
Zimmerli, W., Lew, P. D., & Waldvogel, F. A. (1984) · Journal of Clinical Investigation · doi:10.1172/jci111305 · Cited by 485 · cited 1×
“Alternatively, slime-producing organisms may escape phagocytosis only in the presence of a foreign body (6, 38, 39).”
BackgroundStaphylococcus epidermidis: An Increasing Cause of Infection in Patients with Granulocytopenia
Wade, J. C., SCHIMPFF, S. C., NEWMAN, K. A., & Wiernik, P. H. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-97-4-503 · Cited by 461
Fimbriae and adhesive properties in salmonellae
Duguid, J. P., Anderson, E. S., & Campbell, I. (1966) · The Journal of Pathology and Bacteriology · doi:10.1002/path.1700920113 · Cited by 407
KARCHMER, A. W., ARCHER, G. L., & DISMUKES, W. E. (1983) · Annals of Internal Medicine · doi:10.7326/0003-4819-98-4-447 · Cited by 395 · cited 1×
“Infections caused by coagulase-negative staphylococci have occurred in association with implantable medical devices such as ventriculoperitoneal shunts, prosthetic heart valves, vascular grafts, and hip prostheses (17, 21, 33).”
BackgroundFimbriæ and adhesive properties in dysentery bacilli
Duguid, J. P., & Gillies, R. R. (1957) · The Journal of Pathology and Bacteriology · doi:10.1002/path.1700740218 · Cited by 336
Bacterial Adherence to Surgical Sutures: A Possible Factor in Suture Induced Infection
KATZ, S., IZHAR, M., & MIRELMAN, D. (1981) · Annals of Surgery · doi:10.1097/00000658-198107000-00007 · Cited by 326
Nosocomial Septicemia Due to Multiply Antibiotic-Resistant Staphylococcus epidermidis
CHRISTENSEN, G. D., BISNO, A. L., PARISI, J. T., McLAUGHLIN, B., HESTER, M. G., & LUTHER, R. W. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-96-1-1 · Cited by 308
Cited by
New method for detecting slime production by coagulase negative staphylococci.
Freeman, D. J., Falkiner, F. R., & Keane, C. T. (1989) · Journal of Clinical Pathology · doi:10.1136/jcp.42.8.872 · Cited by 1,319
Mack, D., Fischer, W., Krokotsch, A., Leopold, K., Hartmann, R., Egge, H., & Laufs, R. (1996) · Journal of Bacteriology · doi:10.1128/jb.178.1.175-183.1996 · Cited by 885
Herrmann, M., Vaudaux, P. E., Pittet, D., Auckenthaler, R., Lew, P. D., Perdreau, F. S., Peters, G., & Waldvogel, F. A. (1988) · The Journal of Infectious Diseases · doi:10.1093/infdis/158.4.693 · Cited by 522
Mack, D., Siemssen, N., & Laufs, R. (1992) · Infection and Immunity · doi:10.1128/iai.60.5.2048-2057.1992 · Cited by 372
Laboratory, clinical, and epidemiological aspects of coagulase-negative staphylococci
Pfaller, M. A., & Herwaldt, L. A. (1988) · Clinical Microbiology Reviews · doi:10.1128/cmr.1.3.281 · Cited by 351
Mack, D., Nedelmann, M., Krokotsch, A., Schwarzkopf, A., Heesemann, J., & Laufs, R. (1994) · Infection and Immunity · doi:10.1128/iai.62.8.3244-3253.1994 · Cited by 344
Hussain, M., Herrmann, M., von Eiff, C., Perdreau-Remington, F., & Peters, G. (1997) · Infection and Immunity · doi:10.1128/iai.65.2.519-524.1997 · Cited by 307
Rupp, M. E., Ulphani, J. S., Fey, P. D., Bartscht, K., & Mack, D. (1999) · Infection and Immunity · doi:10.1128/iai.67.5.2627-2632.1999 · Cited by 297
Souvenir, D., Anderson, D. E., Palpant, S., Mroch, H., Askin, S., Anderson, J., Claridge, J., Eiland, J., Malone, C., Garrison, M. W., et al. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.7.1923-1926.1998 · Cited by 289
Isolation and Characterization of a Capsular Polysaccharide Adhesin from Staphylococcus epidermidis
Tojo, M., Yamashita, N., Goldmann, D. A., & Pier, G. B. (1988) · Journal of Infectious Diseases · doi:10.1093/infdis/157.4.713 · Cited by 262
Genotypic variation and slime production among blood and catheter isolates of Candida parapsilosis
Branchini, M. L., Pfaller, M. A., Rhine-Chalberg, J., Frempong, T., & Isenberg, H. D. (1994) · Journal of Clinical Microbiology · doi:10.1128/jcm.32.2.452-456.1994 · Cited by 242
“an epidemiologic marker and a means of discriminating among pathogenic and contaminating isolates from blood cultures (5, 6, 10).”
BackgroundNguyen, H. T. T., Nguyen, T. H., & Otto, M. (2020) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2020.10.027 · Cited by 242
“related infection [147] and an association with origin from infection, for example from nosocomial bacteremia [148], while others”
BackgroundVaudaux, P., Pittet, D., Haeberli, A., Huggler, E., Nydegger, U. E., Lew, D. P., & Waldvogel, F. A. (1989) · Journal of Infectious Diseases · doi:10.1093/infdis/160.5.865 · Cited by 234
Pathogenesis of infections related to intravascular catheterization
Goldmann, D. A., & Pier, G. B. (1993) · Clinical Microbiology Reviews · doi:10.1128/cmr.6.2.176 · Cited by 218
Salzman, M. B., Isenberg, H. D., Shapiro, J. F., Lipsitz, P. J., & Rubin, L. G. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/167.2.487 · Cited by 214
Younger, J. J., Christensen, G. D., Bartleyt, D. L., Simmons, J. C. H., & Barrett, F. F. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.4.548 · Cited by 187
“with a variety of in vitro, in vivo, and epidemiological studies regarding coagulase-negative staphylococci and intravascular catheters [6,19-24], peritoneal dialysis catheters [25,26], and pacemakers [Z7, 28].”
BackgroundThe slime of coagulase-negative staphylococci: Biochemistry and relation to adherence
Hussain, M. (1993) · FEMS Microbiology Letters · doi:10.1016/0378-1097(93)90596-t · Cited by 173
Molecular mechanisms of Staphylococcus epidermidis biofilm formation
Mack, D. (1999) · Journal of Hospital Infection · doi:10.1016/s0195-6701(99)90074-9 · Cited by 163
Phenotypic variation of Staphylococcus epidermidis slime production in vitro and in vivo
Christensen, G. D., Baddour, L. M., & Simpson, W. A. (1987) · Infection and Immunity · doi:10.1128/iai.55.12.2870-2877.1987 · Cited by 159
“Recently other clinical investigators have also noted an association between slime production and pathogenic strains ofCNS (15, 23).”
Background
Metadata
- Authors
- Ishak, M. A., Gröschel, D. H., Mandell, G. L., & Wenzel, R. P.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1985-12
- Volume
- 22
- Issue
- 6
- Pages
- 1025-1029
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2169027034
- Cited by
- 190
- References
- 31
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.