Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 228

The DOI matches its Crossref record.

Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria

Open access
Palmer, Carol J., Lindo, John F., Klaskala, Winslow I., Quesada, Jose A., Kaminsky, Rina, Baum, Marianna K., Ager, Arba L.·1998·Journal of Clinical Microbiology

Abstract

The development of rapid and specific diagnostic tests to identify individuals infected with malaria is of paramount importance in efforts to control the severe public health impact of this disease. This study evaluated the ability of a newly developed rapid malaria diagnostic test, OptiMAL (Flow Inc., Portland, Oreg.), to detect Plasmodium vivax and Plasmodium falciparum malaria during an outbreak in Honduras. OptiMAL is a rapid (10-min) malaria detection test which utilizes a dipstick coated with monoclonal antibodies against the intracellular metabolic enzyme parasite lactate dehydrogenase (pLDH). Differentiation of malaria parasites is based on antigenic differences between the pLDH isoforms. Since pLDH is produced only by live Plasmodium parasites, this test has the ability to differentiate live from dead organisms. Results from the OptiMAL test were compared to those obtained by reading 100 fields of traditional Giemsa-stained thick-smear blood films. Whole-blood samples were obtained from 202 patients suspected of having malaria. A total of 96 samples (48%) were positive by blood films, while 91 (45%) were positive by the OptiMAL test. The blood films indicated that 82% (79 of 96) of the patients were positive for P. vivax and 18% (17 of 96) were infected with P. falciparum . The OptiMAL test showed that 81% (74 of 91) were positive for P. vivax and 19% (17 of 91) were positive for P. falciparum . These results demonstrated that the OptiMAL test had sensitivities of 94 and 88% and specificities of 100 and 99%, respectively, when compared to traditional blood films for the detection of P. vivax and P. falciparum malaria. Blood samples not identified by OptiMAL as malaria positive normally contained parasites at concentrations of less than 100/μl of blood. Samples found to contain P. falciparum were further tested by two other commercially available rapid malaria diagnostic tests, ParaSight-F (Becton Dickinson, Cockeysville, Md.) and ICT Malaria P.f. (ICT Diagnostics, Sydney, Australia), both of which detect only P. falciparum . Only 11 of the 17 (65%) P. falciparum -positive blood samples were identified by the ICT and ParaSight-F tests. Thus, OptiMAL correctly identified P. falciparum malaria parasites in patient blood samples more often than did the other two commercially available diagnostic tests and showed an excellent correlation with traditional blood films in the identification of both P. vivax malaria and P. falciparum malaria. We conclude that the OptiMAL test is an effective tool for the rapid diagnosis of malaria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.36.1.203-206.1998

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Palmer, C. J., Lindo, J. F., Klaskala, W. I., Quesada, J. A., Kaminsky, R., Baum, M. K., & Ager, A. L.
Venue
Journal of Clinical Microbiology
Published
1998-01
Volume
36
Issue
1
Pages
203-206
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2124136925
Cited by
228
References
0
FWCI
16.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria. https://app.cochat.ai/papers/10.1128/jcm.36.1.203-206.1998
The paper
Palmer, C. J., Lindo, J. F., Klaskala, W. I., Quesada, J. A., Kaminsky, R., Baum, M. K., & Ager, A. L. (1998). Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.36.1.203-206.1998

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.