CoChat

Detection of Antigen in Sera of Patients with Invasive Aspergillosis: Intra- and Interlaboratory Reproducibility

Open access
Verweij, Paul E., Erjavec, Zoran, Sluiters, Wim, Goessens, Wil, Rozenberg-Arska, Marja, Debets-Ossenkopp, Yvette J., Guiot, Henri F. L., Meis, Jacques F. G. M. · 1998 · Journal of Clinical Microbiology
Cited by 64

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The intra- and interlaboratory reproducibilities of a commercial sandwich enzyme-linked immunosorbent assay (ELISA) for the detection of Aspergillus galactomannan in serum (Platelia Aspergillus; Sanofi Diagnostics Pasteur, Marnes-La-Coquette, France) were evaluated in six laboratories of university hospitals. Twenty serum samples were obtained from 12 neutropenic patients including 6 with invasive aspergillosis. These samples were blinded and sent to each center together with eight blinded ELISA-negative serum samples spiked with known concentrations of galactomannan. The centers were provided with ELISA microtiter plates from a single batch and a detailed protocol. Ten clinical samples showed ELISA reactivity, while 10 samples were ELISA negative. The mean coefficient of variation (CV) of the optical density values was 4.24% within a single assay and 25.6% between runs. The interassay CV of the ratios for the serum samples tested was 18.6%. Analysis of ordinal interpretation of the ELISA result (i.e., negative, gray zone, or positive) showed excellent reproducibility. Recalculation of the cutoff values for positive and negative samples suggested that the cutoff level recommended by the manufacturer could be lowered from 1.0 to 0.8 for negative samples and from 1.5 to 1.0 for positive samples. The intra- and interlaboratory reproducibilities were excellent when the ELISA results were interpreted as ordinal data, but considerable variation in optical density values and, to a lesser extent, in the ratios for the serum samples tested, was observed between runs. High assay variability was also found for serum samples spiked with known concentrations of galactomannan. Therefore, antigen titers in serum samples from a single patient, measured in different runs, should be compared with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.36.6.1612-1616.1998

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 64

Metadata

Authors
Verweij, P. E., Erjavec, Z., Sluiters, W., Goessens, W., Rozenberg-Arska, M., Debets-Ossenkopp, Y. J., Guiot, H. F. L., & Meis, J. F. G. M.
Venue
Journal of Clinical Microbiology
Published
1998-06
Volume
36
Issue
6
Pages
1612-1616
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2114580519
Cited by
64
References
2
FWCI
3.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Antigen in Sera of Patients with Invasive Aspergillosis: Intra- and Interlaboratory Reproducibility. https://app.cochat.ai/papers/10.1128/jcm.36.6.1612-1616.1998
The paper
Verweij, P. E., Erjavec, Z., Sluiters, W., Goessens, W., Rozenberg-Arska, M., Debets-Ossenkopp, Y. J., Guiot, H. F. L., & Meis, J. F. G. M. (1998). Detection of Antigen in Sera of Patients with Invasive Aspergillosis: Intra- and Interlaboratory Reproducibility. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.36.6.1612-1616.1998

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).