The DOI matches its Crossref record.
Detection of Herpes Simplex Virus DNA by Real-Time PCR
Open accessAbstract
Molecular detection of herpes simplex virus (HSV) DNA is recognized as the reference standard assay method for the sensitive and specific diagnosis of central nervous system infections caused by HSV. In this study, a molecular assay based on real-time PCR on the LightCycler (LC) instrument was evaluated and compared with a home-brew molecular assay. The detection limit of the LC assay was determined with 10-fold dilutions of plasmid pS4 with the Sal I restriction fragment of the DNA polymerase gene and with the First European Union Concerted Action HSV Proficiency Panel. A total of 59 cerebrospinal fluid (CSF) specimens were investigated for the comparative study. With plasmid pS4, the detection limit of the LC assay was found to be 10 4 copies per ml, i.e., 12.5 copies per run. When samples of the First European Union Concerted Action HSV Proficiency Panel were tested, 2 × 10 3 to 5 × 10 3 HSV type 1 genome equivalents (GE) per ml, i.e., 2.5 to 6.3 GE per run, could consistently be detected. There was a correlation between the LC assay and the home-brew assay in 55 of 59 specimens. In conclusion, the LC assay allows very rapid detection of HSV DNA in CSF. It was found to be laborsaving and showed sufficient sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 30
- Aslanzadeh J. Garner J. G. Feder H. M. Ryan R. W. Use of polymerase chain reaction for laboratory diagnosis of herpes simplex virus encephalitis.Ann. Clin. Lab. Sci.231993196202
- 10.1111/1523-1747.ep12277397 · DOI · Paper page
- 10.1111/1523-1747.ep12277232 · DOI
- 10.1086/514657 · DOI
- 10.1128/JCM.38.2.795-799.2000 · DOI · Paper page
- 10.1016/S0002-9394(14)72113-0 · DOI
- 10.1038/nbt0492-413 · DOI · Paper page
- 10.1128/JCM.36.7.2120-2122.1998 · doi:10.1128/jcm.36.7.2120-2122.1998
- 10.1093/clinchem/46.3.324 · DOI · Paper page
- 10.1128/jcm.32.8.1881-1886.1994 · DOI
- Kessler H. H. Qualitative detection of herpes simplex virus DNA on the LightCycler.Rapid cycle real-time PCR—methods and applications in press.MeuerS.WittwerC. T.NakagawaraK.2000Springer-VerlagHeidelberg Germany · doi:10.1007/978-3-642-59524-0_35
- 10.1002/jmv.1890320413 · DOI
- 10.1136/jnnp.60.2.174 · DOI
- Landt O. Selection of hybridization probe sequences for use with the LightCycler.Rapid cycle real-time PCR—methods and applications in press.MeuerS.WittwerC. T.NakagawaraK.2000Springer-VerlagHeidelberg Germany
- 10.1002/j.1460-2075.1987.tb04735.x · DOI · Paper page
- 10.1089/dna.1.1984.3.23 · doi:10.1089/dna.1.1984.3.23
- 10.1016/S1386-6532(99)00047-5 · doi:10.1016/s1386-6532(99)00047-5
- 10.1128/jcm.35.11.2873-2877.1997 · DOI
- 10.1093/clinchem/45.11.1932 · DOI
- 10.1016/0140-6736(90)90648-O · doi:10.1016/0140-6736(90)90648-o
- 10.1128/jcm.35.3.691-696.1997 · DOI
- 10.1016/0140-6736(90)90667-T · DOI · Paper page
- 10.1128/jcm.29.11.2412-2417.1991 · DOI
- 10.1016/0166-0934(94)90174-0 · doi:10.1016/0166-0934(94)90174-0
- 10.1016/0378-1119(87)90039-4 · doi:10.1016/0378-1119(87)90039-4
- 10.1016/0923-2516(96)81085-5 · DOI
- 10.1126/science.6289440 · doi:10.1126/science.6289440
- 10.1086/514600 · DOI · Paper page
- 10.2144/97221pf02 · DOI · Paper page
- Zandotti C. de Lamballerie X. Guignole-Vignoli C. Bollet C. de Micco P. A rapid DNA extraction method from culture and clinical samples. Suitable for the detection of human cytomegalovirus by the polymerase chain reaction.Acta Virol.371993106108
Cited by
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Drosten, C., Seilmaier, M., Corman, V. M., Hartmann, W., Scheible, G., Sack, S., Guggemos, W., Kallies, R., Muth, D., Junglen, S., et al. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70154-3 · Cited by 387
Viral encephalitis: a review of diagnostic methods and guidelines for management
Steiner, I., Budka, H., Chaudhuri, A., Koskiniemi, M., Sainio, K., Salonen, O., & Kennedy, P. G. E. (2005) · European Journal of Neurology · doi:10.1111/j.1468-1331.2005.01126.x · Cited by 367
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Metadata
- Authors
- Kessler, H. H., Mühlbauer, G., Rinner, B., Stelzl, E., Berger, A., Dörr, H.-W., Santner, B., Marth, E., & Rabenau, H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2000-07
- Volume
- 38
- Issue
- 7
- Pages
- 2638-2642
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2172243329
- Cited by
- 174
- References
- 0
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Herpes Simplex Virus DNA by Real-Time PCR. https://app.cochat.ai/papers/10.1128/jcm.38.7.2638-2642.2000
- The paper
- Kessler, H. H., Mühlbauer, G., Rinner, B., Stelzl, E., Berger, A., Dörr, H.-W., Santner, B., Marth, E., & Rabenau, H. (2000). Detection of Herpes Simplex Virus DNA by Real-Time PCR. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.38.7.2638-2642.2000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.