CoChat

Detection of Herpes Simplex Virus DNA by Real-Time PCR

Open access
Kessler, Harald H., Mühlbauer, Gerhard, Rinner, Beate, Stelzl, Evelyn, Berger, Annemarie, Dörr, Hans-Wilhelm, Santner, Brigitte, Marth, Egon, Rabenau, Holger · 2000 · Journal of Clinical Microbiology
Cited by 174

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Molecular detection of herpes simplex virus (HSV) DNA is recognized as the reference standard assay method for the sensitive and specific diagnosis of central nervous system infections caused by HSV. In this study, a molecular assay based on real-time PCR on the LightCycler (LC) instrument was evaluated and compared with a home-brew molecular assay. The detection limit of the LC assay was determined with 10-fold dilutions of plasmid pS4 with the Sal I restriction fragment of the DNA polymerase gene and with the First European Union Concerted Action HSV Proficiency Panel. A total of 59 cerebrospinal fluid (CSF) specimens were investigated for the comparative study. With plasmid pS4, the detection limit of the LC assay was found to be 10 4 copies per ml, i.e., 12.5 copies per run. When samples of the First European Union Concerted Action HSV Proficiency Panel were tested, 2 × 10 3 to 5 × 10 3 HSV type 1 genome equivalents (GE) per ml, i.e., 2.5 to 6.3 GE per run, could consistently be detected. There was a correlation between the LC assay and the home-brew assay in 55 of 59 specimens. In conclusion, the LC assay allows very rapid detection of HSV DNA in CSF. It was found to be laborsaving and showed sufficient sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.38.7.2638-2642.2000

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 9

  1. 10.1128/JCM.36.7.2120-2122.1998 · doi:10.1128/jcm.36.7.2120-2122.1998
  2. Kessler H. H. Qualitative detection of herpes simplex virus DNA on the LightCycler.Rapid cycle real-time PCR—methods and applications in press.MeuerS.WittwerC. T.NakagawaraK.2000Springer-VerlagHeidelberg Germany · doi:10.1007/978-3-642-59524-0_35
  3. Landt O. Selection of hybridization probe sequences for use with the LightCycler.Rapid cycle real-time PCR—methods and applications in press.MeuerS.WittwerC. T.NakagawaraK.2000Springer-VerlagHeidelberg Germany
  4. 10.1089/dna.1.1984.3.23 · doi:10.1089/dna.1.1984.3.23
  5. 10.1016/S1386-6532(99)00047-5 · doi:10.1016/s1386-6532(99)00047-5
  6. 10.1016/0166-0934(94)90174-0 · doi:10.1016/0166-0934(94)90174-0
  7. 10.1016/0378-1119(87)90039-4 · doi:10.1016/0378-1119(87)90039-4
  8. 10.1126/science.6289440 · DOI
  9. Zandotti C. de Lamballerie X. Guignole-Vignoli C. Bollet C. de Micco P. A rapid DNA extraction method from culture and clinical samples. Suitable for the detection of human cytomegalovirus by the polymerase chain reaction.Acta Virol.371993106108

Cited by

See all 174

Metadata

Authors
Kessler, H. H., Mühlbauer, G., Rinner, B., Stelzl, E., Berger, A., Dörr, H.-W., Santner, B., Marth, E., & Rabenau, H.
Venue
Journal of Clinical Microbiology
Published
2000-07
Volume
38
Issue
7
Pages
2638-2642
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2172243329
Cited by
174
References
21
FWCI
7.73
Type
journal article
Language
en
Open access
green
Licence
journals.asm.org/non-commercial-tdm-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.