Detection of Herpes Simplex Virus DNA by Real-Time PCR
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Molecular detection of herpes simplex virus (HSV) DNA is recognized as the reference standard assay method for the sensitive and specific diagnosis of central nervous system infections caused by HSV. In this study, a molecular assay based on real-time PCR on the LightCycler (LC) instrument was evaluated and compared with a home-brew molecular assay. The detection limit of the LC assay was determined with 10-fold dilutions of plasmid pS4 with the Sal I restriction fragment of the DNA polymerase gene and with the First European Union Concerted Action HSV Proficiency Panel. A total of 59 cerebrospinal fluid (CSF) specimens were investigated for the comparative study. With plasmid pS4, the detection limit of the LC assay was found to be 10 4 copies per ml, i.e., 12.5 copies per run. When samples of the First European Union Concerted Action HSV Proficiency Panel were tested, 2 × 10 3 to 5 × 10 3 HSV type 1 genome equivalents (GE) per ml, i.e., 2.5 to 6.3 GE per run, could consistently be detected. There was a correlation between the LC assay and the home-brew assay in 55 of 59 specimens. In conclusion, the LC assay allows very rapid detection of HSV DNA in CSF. It was found to be laborsaving and showed sufficient sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whitley, R. J., Kimberlin, D. W., & Roizman, B. (1998) · Clinical Infectious Diseases · doi:10.1086/514600 · Cited by 1,149
Simultaneous Amplification and Detection of Specific DNA Sequences
Higuchi, R., Dollinger, G., Walsh, P. S., & Griffith, R. (1992) · Bio/Technology · doi:10.1038/nbt0492-413 · Cited by 1,130
The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893 · cited 1×
“The LightCycler (LC) instrument, which allows high-speed thermal cycling by using air instead of thermal blocks and online realtime fluorescence monitoring, has recently been introduced (29).”
BackgroundRowley, A. H., Wolinsky, S. M., Whitley, R. J., & Lakeman, F. D. (1990) · The Lancet · doi:10.1016/0140-6736(90)90667-t · Cited by 292
Related functional domains in virus DNA polymerases.
Larder, B. A., Kemp, S. D., & Darby, G. (1987) · The EMBO Journal · doi:10.1002/j.1460-2075.1987.tb04735.x · Cited by 243 · cited 1×
“For the real-time PCR assay, oligonucleotides deduced from the published sequence of the DNA polymerase gene-coding region from HSV were used (15, 25).”
MethodDiagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR
Espy, M. J., Uhl, J. R., Mitchell, P. S., Thorvilson, J. N., Svien, K. A., Wold, A. D., & Smith, T. F. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.2.795-799.2000 · Cited by 239 · cited 1×
“With regard to utilization of the LC technology for detection of pathogens, there have been very few studies published thus far (5, 9, 19).”
MethodDevelopment of Conventional and Real-Time PCR Assays for the Rapid Detection of Group B Streptococci
Ke, D., Ménard, C., Picard, F. J., Boissinot, M., Ouellette, M., Roy, P. H., & Bergeron, M. G. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.3.324 · Cited by 214 · cited 1×
“With regard to utilization of the LC technology for detection of pathogens, there have been very few studies published thus far (5, 9, 19).”
MethodDetection of Herpes Simplex Virus DNA in Cutaneous Lesions of Erythema Multiforme
Brice, S. L., Krzemien, D., Weston, W. L., & Huff, J. C. (1989) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12277397 · Cited by 193 · cited 1×
“This set of primers, which was chosen within a highly conserved region of the DNA polymerase gene from the herpesvirus group, allows amplification of a 92-bp fragment from each of the HSV-1 and HSV-2 DNA polymerase genes in clinical samples (2, 3).”
BackgroundAseptic meningitis and encephalitis: the role of PCR in the diagnostic laboratory
Read, S. J., Jeffery, K. J., & Bangham, C. R. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.3.691-696.1997 · Cited by 156 · cited 1×
“This set of primers has recently been used for diagnosis of herpes simplex virus encephalitis by nested PCR (20, 21).”
MethodRozenberg, F., & Lebon, P. (1991) · Journal of Clinical Microbiology · doi:10.1128/jcm.29.11.2412-2417.1991 · Cited by 139
Different Real-Time PCR Formats Compared for the Quantitative Detection of Human Cytomegalovirus DNA
Nitsche, A., Steuer, N., Schmidt, C. A., Landt, O., & Siegert, W. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.11.1932 · Cited by 128 · cited 1×
“With regard to utilization of the LC technology for detection of pathogens, there have been very few studies published thus far (5, 9, 19).”
MethodRapid Detection of Cutaneous Herpes Simplex Virus Infection with the Polymerase Chain Reaction
Cao, M., Xiao, X., Egbert, B. M., Darragh, T. M., & Yen, T. S. B. (1989) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12277232 · Cited by 116 · cited 1×
“This set of primers, which was chosen within a highly conserved region of the DNA polymerase gene from the herpesvirus group, allows amplification of a 92-bp fragment from each of the HSV-1 and HSV-2 DNA polymerase genes in clinical samples (2, 3).”
BackgroundMitchell, P. S., Espy, M. J., Smith, T. F., Toal, D. R., Rys, P. N., Berbari, E. F., Osmon, D. R., & Persing, D. H. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.11.2873-2877.1997 · Cited by 115 · cited 1×
“Today, PCR is recognized as the reference standard assay method for the sensitive and specific diagnosis of CNS infections caused by HSV (1, 4, 13, 17, 18).”
MethodNon-invasive diagnosis of herpes simplex encephalitis
Powell, K. F., Anderson, N. E., Frith, R., & Croxson, M. C. (1990) · The Lancet · doi:10.1016/0140-6736(90)90648-o · Cited by 80 · cited 1×
“This set of primers has recently been used for diagnosis of herpes simplex virus encephalitis by nested PCR (20, 21).”
MethodKoskiniemi, M., Piiparinen, H., Mannonen, L., Rantalaiho, T., & Vaheri, A. I. (1996) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.60.2.174 · Cited by 73 · cited 1×
“Today, PCR is recognized as the reference standard assay method for the sensitive and specific diagnosis of CNS infections caused by HSV (1, 4, 13, 17, 18).”
MethodKlapper, P. E., Cleator, G. M., Dennett, C., & Lewis, A. G. (1990) · Journal of Medical Virology · doi:10.1002/jmv.1890320413 · Cited by 71 · cited 1×
“These assays commonly involve toxic and/or radioactive substances and a high number of manipulations (12, 22, 23).”
BackgroundCinque, P. M., Vago, L., Marenzi, R., Giudici, B., Weber, T., Corradini, R., Ceresa, D., Lazzarin, A., & Linde, A. (1998) · Clinical Infectious Diseases · doi:10.1086/514657 · Cited by 66 · cited 1×
“Today, PCR is recognized as the reference standard assay method for the sensitive and specific diagnosis of CNS infections caused by HSV (1, 4, 13, 17, 18).”
MethodKessler, H. H., Pierer, K., Weber, B., Sakrauski, A., Santner, B. I., Stünzner, D., Gergely, E., & Marth, E. (1994) · Journal of Clinical Microbiology · doi:10.1128/jcm.32.8.1881-1886.1994 · Cited by 34 · cited 1×
“To replace these shortcomings, molecular assays including rapid extraction protocols with nontoxic substances and detection protocols based on nonradioactive and largely automated methods have been developed (10, 24).”
MethodSelf-citationAdvantage of a rapid extraction method of HIV1 DNA suitable for polymerase chain reaction
Vignoli, C., de Lamballerie, X. N., Zandotti, C., Tamalet, C., & de Micco, P. (1995) · Research in Virology · doi:10.1016/0923-2516(96)81085-5 · Cited by 20 · cited 1×
“It has, however, been reported that even Chelex 100 may decrease false-negative results due to PCR inhibitors (26).”
BackgroundEssary, L. R., KINARD, S. J., Butcher, A. C., Wang, H., Laycock, K. A., Donegan, E. A., McCREEDY, B., CONNELL, S., BATCHELOR, J., HARRIS, J., et al. (1996) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)72113-0 · Cited by 9
Use of polymerase chain reaction for laboratory diagnosis of herpes simplex virus encephalitis.
Aslanzadeh, J., Garner, J. G., Hm, F., & Ryan, R. W. (1993) · PubMed · Cited by 9
Research works printed but not linked: 9
- 10.1128/JCM.36.7.2120-2122.1998 · doi:10.1128/jcm.36.7.2120-2122.1998
- Kessler H. H. Qualitative detection of herpes simplex virus DNA on the LightCycler.Rapid cycle real-time PCR—methods and applications in press.MeuerS.WittwerC. T.NakagawaraK.2000Springer-VerlagHeidelberg Germany · doi:10.1007/978-3-642-59524-0_35
- Landt O. Selection of hybridization probe sequences for use with the LightCycler.Rapid cycle real-time PCR—methods and applications in press.MeuerS.WittwerC. T.NakagawaraK.2000Springer-VerlagHeidelberg Germany
- 10.1089/dna.1.1984.3.23 · doi:10.1089/dna.1.1984.3.23
- 10.1016/S1386-6532(99)00047-5 · doi:10.1016/s1386-6532(99)00047-5
- 10.1016/0166-0934(94)90174-0 · doi:10.1016/0166-0934(94)90174-0
- 10.1016/0378-1119(87)90039-4 · doi:10.1016/0378-1119(87)90039-4
- 10.1126/science.6289440 · DOI
- Zandotti C. de Lamballerie X. Guignole-Vignoli C. Bollet C. de Micco P. A rapid DNA extraction method from culture and clinical samples. Suitable for the detection of human cytomegalovirus by the polymerase chain reaction.Acta Virol.371993106108
Cited by
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Drosten, C., Seilmaier, M., Corman, V. M., Hartmann, W., Scheible, G., Sack, S., Guggemos, W., Kallies, R., Muth, D., Junglen, S., et al. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70154-3 · Cited by 387
Viral encephalitis: a review of diagnostic methods and guidelines for management
Steiner, I., Budka, H., Chaudhuri, A., Koskiniemi, M., Sainio, K., Salonen, O., & Kennedy, P. G. E. (2005) · European Journal of Neurology · doi:10.1111/j.1468-1331.2005.01126.x · Cited by 367
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Metadata
- Authors
- Kessler, H. H., Mühlbauer, G., Rinner, B., Stelzl, E., Berger, A., Dörr, H.-W., Santner, B., Marth, E., & Rabenau, H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2000-07
- Volume
- 38
- Issue
- 7
- Pages
- 2638-2642
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2172243329
- Cited by
- 174
- References
- 21
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.