CoChat

Devices for Rapid Diagnosis of Malaria: Evaluation of Prototype Assays That Detect Plasmodium falciparum Histidine-Rich Protein 2 and a Plasmodium vivax -Specific Antigen

Open access
Forney, J. Russ, Wongsrichanalai, Chansuda, Magill, Alan J., Craig, Leslie G., Sirichaisinthop, Jeeraphat, Bautista, Christian T., Miller, R. Scott, Ockenhouse, Christian F., Kester, Kent E., Aronson, Naomi E., Andersen, Ellen M., Quino-Ascurra, Higinio A., Vidal, Carlos, Moran, Kimberly A., Murray, Clinton K., DeWitt, Caroline Cady, Heppner, D. Gray, Kain, Kevin C., Ballou, W. Ripley, Gasser, Robert A. · 2003 · Journal of Clinical Microbiology
Cited by 75

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The Para Sight F test was developed as a pioneer industry effort in the large-scale, process-controlled production of a device for the rapid diagnosis of malaria. This device performed well in field settings but was limited to the detection of a single malaria species, Plasmodium falciparum. The Para Sight F+V assay advanced upon the Para Sight F test format by incorporating a monoclonal antibody directed against a proprietary Plasmodium vivax -specific antigen, in addition to the antibody directed against P. falciparum histidine-rich protein 2, which was used in the Para Sight F assay. The modified assay was developed to add the capability to detect P. falciparum and P. vivax in a single-test-strip format. The present study evaluated three distinct Para Sight F+V prototypes with samples from symptomatic patients in regions of Thailand and Peru where malaria is endemic. Over a 2-year enrollment period (1998 and 1999), a total of 4,894 patients consented to participation in the study. Compared with the results for duplicate microscopic examinations of Giemsa-stained blood smears as the reference diagnostic standard, each successive prototype showed substantial improvement in performance. The final Para Sight F+V prototype, evaluated in 1999, had an overall sensitivity for detection of asexual P. falciparum parasites of 98%. The sensitivity of the device was 100% for P. falciparum densities of >500 parasites/μl, with a sensitivity of 83% for parasite densities of ≤500/μl. The specificity for the exclusion of P. falciparum was 93%. For P. vivax , the overall sensitivity was 87% for the final 1999 prototype. The sensitivities calculated for different levels of P. vivax parasitemia were 99% for parasite densities of >5,000/μl, 92% for parasite densities of 1,001 to 5,000/μl, 94% for parasite densities of 501 to 1,000/μl, and 55% for parasite densities of 1 to 500/μl. The specificity for the exclusion of P. vivax was 87%. The areas under the receiver operating characteristic curves for the diagnostic performance of the assay for the detection of P. falciparum and P. vivax were 0.8907 and 0.8522, respectively. These findings indicate that assays for rapid diagnosis have the potential to enhance diagnostic capabilities in those instances in which skilled microscopy is not readily available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.41.6.2358-2366.2003

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 75

Metadata

Authors
Forney, J. R., Wongsrichanalai, C., Magill, A. J., Craig, L. G., Sirichaisinthop, J., Bautista, C. T., Miller, R. S., Ockenhouse, C. F., Kester, K. E., Aronson, N. E., Andersen, E. M., Quino-Ascurra, H. A., Vidal, C., Moran, K. A., Murray, C. K., DeWitt, C. C., Heppner, D. G., Kain, K. C., Ballou, W. R., & Gasser, R. A.
Venue
Journal of Clinical Microbiology
Published
2003-06
Volume
41
Issue
6
Pages
2358-2366
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2172211106
Cited by
75
References
4
FWCI
5.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.