Loop-Mediated Isothermal Amplification for Direct Detection of Mycobacterium tuberculosis Complex, M. avium , and M. intracellulare in Sputum Samples
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method in which reagents react under isothermal conditions with high specificity, efficiency, and rapidity. We used LAMP for detection of Mycobacterium tuberculosis complex, Mycobacterium avium , and Mycobacterium intracellulare directly from sputum specimens as well as for detection of culture isolates grown in a liquid medium (MGIT; Nippon Becton Dickinson Co., Ltd., Tokyo, Japan) or on a solid medium (Ogawa's medium). Species-specific primers were designed by targeting the gyrB gene, and their specificities were validated on 24 mycobacterial species and 7 nonmycobacterial species. The whole procedure is quite simple, starting with the mixing of all reagents in a single tube, followed by an isothermal reaction during which the reaction mixture is held at 63°C. The resulting amplicons are visualized by adding SYBR Green I to the reaction tube. The only equipment needed for the amplification reaction is a regular laboratory water bath or heat block that furnishes a constant temperature of 63°C. The assay had a detection limit of 5 to 50 copies of purified DNA with a 60-min incubation time. The reaction time could be shortened to 35 min for the species identification of M. tuberculosis complex, M. avium , and M. intracellulare from a solid-medium culture. Residual DNA lysates prepared for the Amplicor assay (Roche Diagnostics GmbH) from 66 sputum specimens were tested in the LAMP assay. Although the sample size used for the latter assay was small, 2.75 μl of the DNA lysates, it showed a performance comparable with that of the Amplicor assay, which required 50 μl of the lysates. This LAMP-based assay is simple, rapid, and sensitive; a result is available in 35 min for a solid-medium culture and in 60 min for a liquid-medium culture or for a sputum specimen that contains a corresponding amount of DNA available for testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Mori, Y., Nagamine, K., Tomita, N., & Notomi, T. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5921 · Cited by 1,711
Rosenstraus, M., Wang, Z., Chang, S.-Y., DeBonville, D., & Spadoro, J. P. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.1.191-197.1998 · Cited by 261
Differentiation of Phylogenetically Related Slowly Growing Mycobacteria by Their gyrB Sequences
Kasai, H., Ezaki, T., & Harayama, S. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.1.301-308.2000 · Cited by 211
Abe, C., Hirano, K., Wada, M., Kazumi, Y., Takahashi, M., Fukasawa, Y., Yoshimura, T., Miyagi, C., & Goto, S. (1993) · Journal of Clinical Microbiology · doi:10.1128/jcm.31.12.3270-3274.1993 · Cited by 202
Pfyffer, G. E., Kissling, P., Jahn, E. M., Welscher, H. M., Salfinger, M., & Weber, R. (1996) · Journal of Clinical Microbiology · doi:10.1128/jcm.34.4.834-841.1996 · Cited by 166
Nucleic acid sequence-based amplification (NASBA) for the identification of mycobacteria
Gabrielle, M. E., van der, V., Schukkink, R. A. F., van Gemen, B., y Schepers, & y Klatser (1993) · Journal of General Microbiology · doi:10.1099/00221287-139-10-2423 · Cited by 132
RIDOM: Ribosomal Differentiation of Medical Micro-organisms Database
Harmsen, D. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.1.416 · Cited by 118
Diagnosis of tuberculosis by Amplicor Mycobacterium tuberculosis test: a multicenter study
Carpentier, E., Drouillard, B., Dailloux, M., Moinard, D., Vallee, E., Dutilh, B., Maugein, J., Bergogne-Bérézin, E., & Carbonnelle, B. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.12.3106-3110.1995 · Cited by 96
Cited by
Mori, Y., & Notomi, T. (2009) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-009-0669-9 · Cited by 1,015
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Craw, P., & Balachandran, W. (2012) · Lab on a Chip · doi:10.1039/c2lc40100b · Cited by 766
Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities
Parsons, L. M., Somoskövi, Á., Gutierrez, C., Lee, E., Paramasivan, C. N., Abimiku, A., Spector, S., Roscigno, G., & Nkengasong, J. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00059-10 · Cited by 540
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
Thai, H. T. C., Le, M. Q., Vuong, C. D., Parida, M., Minekawa, H., Notomi, T., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1956-1961.2004 · Cited by 422
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP)
Zhang, X., Lowe, S. B., & Gooding, J. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.039 · Cited by 368
Boehme, C. C., Nabeta, P., Henostroza, G., Raqib, R., Rahim, Z., Gerhardt, M., Sanga, E., Hoelscher, M., Notomi, T., Hase, T., et al. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02352-06 · Cited by 341
Facing the Crisis: Improving the Diagnosis of Tuberculosis in the HIV Era
Perkins, M. D., & Cunningham, J. (2007) · The Journal of Infectious Diseases · doi:10.1086/518656 · Cited by 300
A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses
Priye, A., Bird, S. W., Light, Y. K., Ball, C. S., Negrete, O. A., & Meagher, R. J. (2017) · Scientific Reports · doi:10.1038/srep44778 · Cited by 300
Jiang, Y. (., Li, B., Milligan, J. N., Bhadra, S., & Ellington, A. D. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4023978 · Cited by 292
Rabe, B. A., & Cepko, C. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2011221117 · Cited by 290
Njiru, Z. K., Mikosza, A. S. J., Armstrong, T., Enyaru, J. C., Ndung'u, J. M., & Thompson, A. R. C. (2008) · PLoS Neglected Tropical Diseases · doi:10.1371/journal.pntd.0000147 · Cited by 268
Isothermal Amplification Methods for the Detection of Nucleic Acids in Microfluidic Devices
Zanoli, L., & Spoto, G. (2012) · Biosensors · doi:10.3390/bios3010018 · Cited by 265
Loop-mediated isothermal amplification (LAMP): A novel rapid detection platform for pathogens
Li, Y., Fan, P., Zhou, S., & Zhang, L. (2017) · Microbial Pathogenesis · doi:10.1016/j.micpath.2017.03.016 · Cited by 257
Cross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens
Fang, R., Li, X., Hu, L., You, Q., Li, J., Wu, J., Xu, P., Zhong, H., Luo, Y., Mei, J., et al. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.01528-08 · Cited by 167
Advances in molecular phytodiagnostics – new solutions for old problems
Mumford, R., Boonham, N., Tomlinson, J., & Barker, I. (2006) · European Journal of Plant Pathology · doi:10.1007/s10658-006-9037-0 · Cited by 164
“…the addition of an intercalating dye such as SYBR Green I to a positive LAMP reaction produces a colour change which allows detection with the naked eye (Iwamoto et al., 2003): this method may improve sensitivity compared to visual detection of magnesium pyrophosphate turbidity (Sun et al., 2006).”
MethodGreco, S., Girardi, E., Navarra, A., & Saltini, C. (2006) · Thorax · doi:10.1136/thx.2005.054908 · Cited by 162
Loop-Mediated Isothermal Amplification for Rapid and Reliable Diagnosis of Tuberculous Meningitis
Nagdev, K. J., Kashyap, R. S., Parida, M. M., Kapgate, R. C., Purohit, H. J., Taori, G. M., & Daginawala, H. F. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.00824-10 · Cited by 86
“LAMP is increasingly used by various investigators to rapidly detect and type mycobacteria in pulmonary samples (1, 2, 3, 8, 12, 21, 25, 33, 34).”
BackgroundYan, L., Xiao, H., & Zhang, Q. (2016) · Tuberculosis · doi:10.1016/j.tube.2015.11.005 · Cited by 72
Metadata
- Authors
- Iwamoto, T., Sonobe, T., & Hayashi, K.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2003-06
- Volume
- 41
- Issue
- 6
- Pages
- 2616-2622
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1984966664
- Cited by
- 612
- References
- 17
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.