Due to the early administration of antibiotics, meningococcal disease is increasingly difficult to diagnose by culturing. Laboratory studies have shown PCR to be sensitive and specific, but there have been few clinical studies. The objectives of this study were to determine the diagnostic accuracy and clinical usefulness of meningococcal PCR through a prospective comparison of real-time PCR, nested PCR, and standard culturing of blood and cerebrospinal fluid (CSF). The setting was a tertiary-care pediatric hospital in Australia, and the participans were 118 children admitted with possible septicemia or meningitis. The main outcome measures—sensitivity, specificity, and positive and negative predictive values—were compared to a “gold standard ” fulfilling clinical and laboratory criteria. For 24 cases of meningococcal disease diagnosed by the gold standard, culturing of blood or CSF was positive for 15 (63%), nested PCR was positive for 21 (88%), and real-time PCR was positive for 23 (96%). The sensitivity, specificity, and positive and negative predictive values of real-time PCR (the most sensitive test) for all specimens were, respectively, 96% (95% confidence interval, 79 to 99%), 100% (95% confidence interval, 96 to100%), 100% (95% confidence interval, 85 to 100%), and 99% (95% confidence interval, 94 to 100%). Of 54 patients with suspected meningococcal disease at admission, 23 had positive PCR results. Only one PCR specimen was positive in a patient thought unlikely to have meningococcal disease at admission. Blood PCR remained positive for 33% of patients tested at up to 72 h. Real-time PCR has high positive and negative predictive values in this clinical setting, with better confirmation of cases than nested PCR. Targeting patients for PCR based on admission criteria appears to be practical, and the test may remain useful for several days after the start of antibiotic administration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.42.7.2919-2925.2004

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 88

Metadata

Authors
Bryant, P. A., Li, H. Y., Zaia, A., Griffith, J., Hogg, G., Curtis, N., & Carapetis, J. R.
Venue
Journal of Clinical Microbiology
Published
2004-07
Volume
42
Issue
7
Pages
2919-2925
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2096713261
Cited by
88
References
6
FWCI
4.43
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective Study of a Real-Time PCR That Is Highly Sensitive, Specific, and Clinically Useful for Diagnosis of Meningococcal Disease in Children. https://app.cochat.ai/papers/10.1128/jcm.42.7.2919-2925.2004
The paper
Bryant, P. A., Li, H. Y., Zaia, A., Griffith, J., Hogg, G., Curtis, N., & Carapetis, J. R. (2004). Prospective Study of a Real-Time PCR That Is Highly Sensitive, Specific, and Clinically Useful for Diagnosis of Meningococcal Disease in Children. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.42.7.2919-2925.2004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.