CoChat

Rapid Detection and Differentiation of Dengue Virus Serotypes by a Real-Time Reverse Transcription-Loop-Mediated Isothermal Amplification Assay

Open access
Parida, Manmohan, Horioke, Kouhei, Ishida, Hiroyuki, Dash, Paban Kumar, Saxena, Parag, Jana, Asha Mukul, Islam, Mohammed Alimul, Inoue, Shingo, Hosaka, Norimitsu, Morita, Kouichi · 2005 · Journal of Clinical Microbiology
Cited by 358

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

The development and validation of a one-step, real-time, and quantitative dengue virus serotype-specific reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay targeting the 3′ noncoding region for the rapid detection and differentiation of dengue virus serotypes are reported. The RT-LAMP assay is very simple and rapid, wherein the amplification can be obtained in 30 min under isothermal conditions at 63°C by employing a set of four serotype-specific primer mixtures through real-time monitoring in an inexpensive turbidimeter. The evaluation of the RT-LAMP assay for use for clinical diagnosis with a limited number of patient serum samples, confirmed to be infected with each serotype, revealed a higher sensitivity by picking up 100% samples as positive, whereas 87% and 81% of the samples were positive by reverse transcription-PCR and virus isolation, respectively. The sensitivity and specificity of the RT-LAMP assay for the detection of viral RNA in patient serum samples with reference to virus isolation were 100% and 93%, respectively. The optimal assay conditions with zero background and no cross-reaction with other closely related members of the Flavivirus family (Japanese encephalitis, West Nile, and St. Louis encephalitis viruses) as well as within the four serotypes of dengue virus were established. None of the serum samples from healthy individuals screened in this study showed any cross-reaction with the four dengue virus serotype-specific RT-LAMP assay primers. These findings demonstrate that RT-LAMP assay has the potential clinical application for detection and differentiation of dengue virus serotypes, especially in developing countries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.43.6.2895-2903.2005

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 358

Metadata

Authors
Parida, M., Horioke, K., Ishida, H., Dash, P. K., Saxena, P., Jana, A. M., Islam, M. A., Inoue, S., Hosaka, N., & Morita, K.
Venue
Journal of Clinical Microbiology
Published
2005-06
Volume
43
Issue
6
Pages
2895-2903
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2160892791
Cited by
358
References
21
FWCI
10.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.