Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Use of Electrochemical DNA Biosensors for Rapid Molecular Identification of Uropathogens in Clinical Urine Specimens

Open access
Liao, Joseph C., Mastali, Mitra, Gau, Vincent, Suchard, Marc A., Møller, Annette K., Bruckner, David A., Babbitt, Jane T., Li, Yang, Gornbein, Jeffrey, Landaw, Elliot M., McCabe, Edward R. B., Churchill, Bernard M., Haake, David A.·2006·Journal of Clinical Microbiology

Abstract

We describe the first species-specific detection of bacterial pathogens in human clinical fluid samples using a microfabricated electrochemical sensor array. Each of the 16 sensors in the array consisted of three single-layer gold electrodes—working, reference, and auxiliary. Each of the working electrodes contained one representative from a library of capture probes, each specific for a clinically relevant bacterial urinary pathogen. The library included probes for Escherichia coli , Proteus mirabilis , Pseudomonas aeruginosa , Enterocococcus spp., and the Klebsiella-Enterobacter group. A bacterial 16S rRNA target derived from single-step bacterial lysis was hybridized both to the biotin-modified capture probe on the sensor surface and to a second, fluorescein-modified detector probe. Detection of the target-probe hybrids was achieved through binding of a horseradish peroxidase (HRP)-conjugated anti-fluorescein antibody to the detector probe. Amperometric measurement of the catalyzed HRP reaction was obtained at a fixed potential of −200 mV between the working and reference electrodes. Species-specific detection of as few as 2,600 uropathogenic bacteria in culture, inoculated urine, and clinical urine samples was achieved within 45 min from the beginning of sample processing. In a feasibility study of this amperometric detection system using blinded clinical urine specimens, the sensor array had 100% sensitivity for direct detection of gram-negative bacteria without nucleic acid purification or amplification. Identification was demonstrated for 98% of gram-negative bacteria for which species-specific probes were available. When combined with a microfluidics-based sample preparation module, the integrated system could serve as a point-of-care device for rapid diagnosis of urinary tract infections.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.44.2.561-570.2006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 211

Metadata

Authors
Liao, J. C., Mastali, M., Gau, V., Suchard, M. A., Møller, A. K., Bruckner, D. A., Babbitt, J. T., Li, Y., Gornbein, J., Landaw, E. M., McCabe, E. R. B., Churchill, B. M., & Haake, D. A.
Venue
Journal of Clinical Microbiology
Published
2006-02
Volume
44
Issue
2
Pages
561-570
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2125434152
Cited by
211
References
3
FWCI
15.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Electrochemical DNA Biosensors for Rapid Molecular Identification of Uropathogens in Clinical Urine Specimens. https://app.cochat.ai/papers/10.1128/jcm.44.2.561-570.2006
The paper
Liao, J. C., Mastali, M., Gau, V., Suchard, M. A., Møller, A. K., Bruckner, D. A., Babbitt, J. T., Li, Y., Gornbein, J., Landaw, E. M., McCabe, E. R. B., Churchill, B. M., & Haake, D. A. (2006). Use of Electrochemical DNA Biosensors for Rapid Molecular Identification of Uropathogens in Clinical Urine Specimens. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.44.2.561-570.2006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.