CoChat

In vitro replication of adeno-associated virus DNA: enhancement by extracts from adenovirus-infected HeLa cells

Open access
Ward, P, Berns, K I · 1996 · Journal of Virology
Cited by 34

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Previously we have described an in vitro assay for the replication of adeno-associated virus type 2 (AAV2) DNA. Addition of the AAV2 nonstructural protein Rep68 to an extract from uninfected cells supports the replication of linear duplex AAV DNA. In this report, we examine replication of linear duplex AAV DNA in extracts from either uninfected or adenovirus (Ad)-infected HeLa cells. The incorporation of radiolabeled nucleotides into full-length linear AAV DNA is 50-fold greater in extracts from Ad-infected cells than in extracts from uninfected cells. In addition, the majority of the labeled full-length AAV DNA molecules synthesized in the Ad-infected extract have two newly replicated strands, whereas the majority of labeled full-length AAV DNA molecules synthesized in the uninfected extract have only one newly replicated strand. The numbers of replication initiations on original templates in the two assays are approximately the same; however, replication in the case of the Ad-infected cell extract is much more likely to result in the synthesis of a full-length AAV DNA molecule. Most of the newly replicated molecules in the assay using uninfected cell extracts are in the form of stem-loop structures. We hypothesize that Ad infection provides a helper function related to elongation during replication by a single-strand displacement mechanism. In the assay using the uninfected HeLa cell extract, replication frequently stalls before reaching the end of the genome, causing the newly synthesized strand to be displaced from the template, with a consequent folding on itself and replication back through the inverted terminal repeat, using itself as a template. In support of this conjecture, replication in the uninfected cell extract of shorter substrate molecules is more efficient, as measured by incorporation of radiolabeled nucleotides into full-length substrate DNA. In addition, when shorter substrate molecules are used as the template in the uninfected HeLa cell assay, a greater proportion of the labeled full-length substrate molecules contain two newly replicated strands. Shorter substrate molecules have no replicative advantage over full-length substrate molecules in the assay using an extract from Ad-infected cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jvi.70.7.4495-4501.1996

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Ward, P., & Berns, K. I.
Venue
Journal of Virology
Published
1996-07
Volume
70
Issue
7
Pages
4495-4501
ISSN
  • 0022-538X (ISSN-L)
  • 1098-5514
OpenAlex
W2138552055
Cited by
34
References
5
FWCI
1.60
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.