Quantification of human papillomavirus cell-free DNA from low-volume blood plasma samples by digital PCR
Published version of a preprint
The DOI matches its Crossref record.
Abstract
The incidence rate of human papillomavirus-driven oropharyngeal cancer (HPV-OPC) is increasing in countries with high human development index. HPV cell-free DNA (cfDNA) isolated from 3 to 4 mL blood plasma has been successfully used for therapy surveillance. A highly discussed application of HPV-cfDNA is early detection of HPV-OPC. This requires sensitive and specific cfDNA detection as cfDNA levels can be very low. To study the predictive power of pre-diagnostic HPV-cfDNA, archived samples from epidemiological cohorts with limited plasma volume are an important source. To establish a cfDNA detection workflow for low plasma volumes, we compared cfDNA purification methods [MagNA Pure 96 (MP96) and QIAamp ccfDNA/RNA] and digital PCR systems (Biorad QX200 and QIAGEN QIAcuity One). Final assay validation included 65 low-volume plasma samples from oropharyngeal cancer (OPC) patients with defined HPV status stored for 2–9 years. MP96 yielded a 28% higher cfDNA isolation efficiency in comparison to QIAamp. Both digital PCR systems showed comparable analytical sensitivity (6–17 copies for HPV16 and HPV33), but QIAcuity detected both types in the same assay. In the validation set, the assay had 80% sensitivity ( n = 28/35) for HPV16 and HPV33 and a specificity of 97% ( n = 29/30). In samples with ≥750 µL plasma, the sensitivity was 85% ( n = 17/20), while in samples with <750 µL plasma, it was 73% ( n = 11/15). Despite the expected drop in sensitivity with decreased plasma volume, the assay is sensitive and highly specific even in low-volume samples and thus suited for studies exploring HPV-cfDNA as an early HPV-OPC detection marker in low-volume archival material. IMPORTANCE: HPV-OPC has a favorable prognosis compared to HPV-negative OPC. However, the majority of tumors is diagnosed after regional spread, thus making intensive treatment necessary. This can cause lasting morbidity with a large impact on quality of life. One potential method to decrease treatment-related morbidity is early detection of the cancer. HPV cfDNA has been successfully used for therapy surveillance and has also been detected in pre-diagnostic samples of HPV-OPC patients. These pre-diagnostic samples are only commonly available from biobanks, which usually only have small volumes of blood plasma available. Hence, we have developed a workflow optimized for small-volume archival samples. With this method, a high sensitivity can be achieved despite sample limitations, making it suitable to conduct further large-scale biobank studies of HPV-cfDNA as a prognostic biomarker for HPV-OPC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, only limited research has been done comparing the performance across different digital PCR platforms using the same DNA material24,26,45.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [45]
In the citing paper
“These studies showed a general agreement between both platforms and suggest that the observed differences might be caused by threshold settings.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [45]
In the citing paper
“Other studies that compared reproducibility and general platform performance have used DNA originating from plasmids, tumor cells, bacteria or viruses25,26,28,45,73.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [45]
In the citing paper
“Comparisons between the QX200 ddPCR and the QIAcuity ndPCR platforms were so far mainly conducted for medical investigations of viruses or mutation analyses25,45.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [45]
In the citing paper
“These studies showed a general agreement between both platforms and suggest that the observed differences might be caused by threshold settings.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [45]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 39
- 10.20892/j.issn.2095-3941.2020.0370 · DOI · Paper page
- 10.1016/j.oraloncology.2013.12.019 · doi:10.1016/j.oraloncology.2013.12.019
- 10.1093/annonc/mds205 · doi:10.1093/annonc/mds205
- 10.1016/j.humpath.2015.12.021 · DOI
- 10.3747/co.26.4819 · DOI
- 10.2147/CMAR.S379173 · DOI
- 10.1016/j.vaccine.2017.05.025 · DOI
- 10.1016/j.lana.2021.100143 · DOI
- Jahr S, Hentze H, Englisch S, Hardt D, Fackelmayer FO, Hesch RD, Knippers R. 2001. DNA fragments in the blood plasma of cancer patients: quantitations and evidence for their origin from apoptotic and necrotic cells. Cancer Res 61:1659–1665.
- 10.1093/clinchem/48.3.421 · DOI · Paper page
- 10.1038/s41598-020-63180-8 · DOI
- 10.1158/1078-0432.CCR-21-2338 · DOI
- 10.1158/1078-0432.CCR-19-0211 · DOI
- 10.1158/1078-0432.CCR-21-3151 · DOI
- 10.1001/jamaoto.2022.4107 · doi:10.1001/jamaoto.2022.4107
- 10.1002/cncr.34109 · DOI
- 10.1016/j.oraloncology.2023.106464 · doi:10.1016/j.oraloncology.2023.106464
- 10.1001/jamaoto.2022.0159 · doi:10.1001/jamaoto.2022.0159
- 10.1016/j.oraloncology.2022.105805 · DOI
- 10.1200/PO.18.00276 · DOI
- 10.1186/s12885-019-5536-1 · DOI
- 10.1016/j.vaccine.2012.06.083 · DOI · Paper page
- 10.1002/ijc.30697 · DOI
- 10.1093/annonc/mdz138 · DOI
- 10.1001/jamaoncol.2020.4527 · doi:10.1001/jamaoncol.2020.4527
- 10.1016/j.eclinm.2022.101659 · doi:10.1016/j.eclinm.2022.101659
- 10.1099/0022-1317-76-4-1057 · DOI · Paper page
- 10.1016/j.ygyno.2015.06.039 · DOI
- 10.1128/JCM.44.2.504-512.2006 · DOI · Paper page
- 10.1016/j.pvr.2016.07.002 · doi:10.1016/j.pvr.2016.07.002
- 10.1093/nar/26.11.2694 · DOI · Paper page
- 10.1038/321246a0 · DOI · Paper page
- 10.1016/0042-6822(85)90214-4 · DOI · Paper page
- 10.21105/joss.01686 · DOI · Paper page
- 10.18637/jss.v028.i05 · DOI · Paper page
- 10.18632/oncotarget.27992 · DOI
- 10.3390/cancers13123010 · DOI
- 10.1158/1078-0432.CCR-19-1490 · doi:10.1158/1078-0432.ccr-19-1490
- 10.3390/v13071342 · DOI
Cited by
Comparing the precision of two digital PCR applications for copy number comparisons in protists
Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-13143-8 · Cited by 6
Metadata
- Authors
- Rosing, F., Meier, M., Schroeder, L., Laban, S., Hoffmann, T., Kaufmann, A., Siefer, O., Wuerdemann, N., Klußmann, J. P., Rieckmann, T., Alt, Y., Faden, D. L., Waterboer, T., & Höfler, D.
- Venue
- Microbiology Spectrum
- Publisher
- American Society for Microbiology
- Published
- 2024-07-02
- Volume
- 12
- Issue
- 7
- ISSN
- 2165-0497
- Cited by
- 9
- References
- 0
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0/ (vor)
- journals.asm.org/non-commercial-tdm-license (tdm)
- Funders
- Deutsches Krebsforschungszentrum
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of human papillomavirus cell-free DNA from low-volume blood plasma samples by digital PCR. https://app.cochat.ai/papers/10.1128/spectrum.00024-24
- The paper
- Rosing, F., Meier, M., Schroeder, L., Laban, S., Hoffmann, T., Kaufmann, A., Siefer, O., Wuerdemann, N., Klußmann, J. P., Rieckmann, T., Alt, Y., Faden, D. L., Waterboer, T., & Höfler, D. (2024). Quantification of human papillomavirus cell-free DNA from low-volume blood plasma samples by digital PCR. Microbiology Spectrum. https://doi.org/10.1128/spectrum.00024-24
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.