Dispersive Liquid–Liquid Microextraction Followed by Solidified Floating Organic Drop for Hexavalent Chromium Determination: a Method for Occupational and Environmental Exposure Monitoring for Heavy Metals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Abstract Dispersive liquid−liquid microextraction solidified floating organic drop (SFOD−DLLME) technique was used for sample treatment and extraction of hexavalent chromium from spiked and real samples of workplace ambient air and urine of chromium electroplating workers. Validation of the SFOD−DLLME technique with three solvents, namely, 1-undecanol, 2-dodecanol and n-hexadecane, showed that pH 4, stirring rates of 600 rpm for 1-undecanol and 2-dodecanol and 800 rpm for n-hexadecane, extraction times of 10 min for 1-undecanol and 2-dodecanol and 15 min for n-hexadecane were the conditions allowing to reach the highest extraction efficiency. The maximum acquired enrichment factor was 211 and LODs were in the range of 0.015–0.05 µg/L, and the calibration curves were linear in the range of 0.5–30 µg/L. The results showed that SFOD−DLLME coupled with atomic absorption spectroscopy is a precise and sensitive technique for the determination of hexavalent chromium for biological monitoring of occupational/environmental samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The pH of the aqueous solution before extraction is an important parameter that affects the analyte-DES complex formation and the extraction of the analytes into especially for ionizable analytes such as Cr(VI) (Sorouraddin et al. 2020, Pourbakhshi 2021).”
In the citing paper
“The volume ratio of organic: aqueous phases is important to reach a higher enrichment factor and extraction efficiency for a lower concentration of the analytes from the larger sample volume (Pourbakhshi et al. 2021).”
From Method Development and Optimization of Liquid-Liquid Microextraction Based on the Decomposition of Deep Eutectic Solvent for the Determination of Chromium (VI) in Spinach: Assessment of the Greenness Profile Using Eco-scale, AGREE, and AGREEprep (2024) · cites this paper as Pourbakhshi et al. 2021
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Analytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. K. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 751
Chromium in the natural and human environments
Nriagu, J. O., & Nieboer, E. (1988) · Wiley eBooks · Cited by 544
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Zeini Jahromi, E., Bidari, A., Assadi, Y., Milani Hosseini, M. R., & Jamali, M. R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.007 · Cited by 398
Chromium in the natural and human environments
Goldberg, E. D. (1989) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(89)90041-0 · Cited by 276
Mirzaei, M., Behzadi, M., Abadi, N. M., & Beizaei, A. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.12.080 · Cited by 193
Mansour, F. R., & Danielson, N. D. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.084 · Cited by 178
Bidabadi, M. S., Dadfarnia, S., & Shabani, A. M. H. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.11.052 · Cited by 140
Saygı, K. Ö., Tüzen, M., Soylak, M., & ELCI, L. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.09.051 · Cited by 134
Speciation of hexavalent chromium in waters by liquid–liquid extraction and GFAAS determination
Béni, Á., Karosi, R., & Posta, J. (2006) · Microchemical Journal · doi:10.1016/j.microc.2006.05.004 · Cited by 132
Dadfarnia, S., Salmanzadeh, A. M., & Shabani, A. M. H. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.033 · Cited by 120
Hemmatkhah, P., Bidari, A., Jafarvand, S., Hosseini, M. R. M., & Assadi, Y. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0167-x · Cited by 111
Moghadam, M. R., Dadfarnia, S., & Shabani, A. M. H. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.10.101 · Cited by 109
Removal of chromium (VI) from water streams: a thermodynamic study
Gallios, G., & Václavíková, M. (2007) · Environmental Chemistry Letters · doi:10.1007/s10311-007-0128-8 · Cited by 101
Recent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Dadfarnia, S., Haji Shabani, A. M., & Kamranzadeh, E. (2009) · Talanta · doi:10.1016/j.talanta.2009.02.004 · Cited by 97
Lü, N., He, X., Wang, T., Liu, S., & Hou, X. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.12.009 · Cited by 91
Matos, G. D., dos Reis, E. B., Costa, A. C. S., & Ferreira, S. L. C. (2009) · Microchemical Journal · doi:10.1016/j.microc.2009.02.009 · Cited by 80
Liang, P., & Sang, H. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.11.017 · Cited by 79
Alves, V. N., & Coelho, N. M. M. (2012) · Microchemical Journal · doi:10.1016/j.microc.2012.05.030 · Cited by 62
Guo, X., He, M., Chen, B., & Hu, B. (2012) · Talanta · doi:10.1016/j.talanta.2012.02.053 · Cited by 62
Ezoddin, M., Shemirani, F., & Khani, R. (2010) · Desalination · doi:10.1016/j.desal.2010.06.007 · Cited by 60
Mandrah, K., Satyanarayana, G. N. V., & Roy, S. K. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.10.071 · Cited by 58
Wen, S., Wu, J., & Zhu, X. (2013) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2012.12.036 · Cited by 44
Speciation of chromium by in-capillary derivatization and electrophoretically mediated microanalysis
Priego‐Capote, F., & de Castro, M. D. L. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.122 · Cited by 27
Xu, L., Miao, X., Li, H., Liang, J., & Yang, Z. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.104091 · Cited by 20
Attari, S. G., Bahrami, A., Shahna, F. G., & Heidari, M. (2015) · Journal of Analytical Chemistry · doi:10.1134/s1061934815100032 · Cited by 9
Self-citation
Research works printed but not linked: 3
- Environmental Protection Agency, Toxicological review of trivalent chromium (CAS no. 16065-83-1), in Support of Summery Information on the Integrated Risk System (IRIS), Washington, DC: US Environmental Protection Agency, 1998.
- Agents Classified by the IARC Monographs, vol. 1–120, 2012. http://monographs.iarc.fr/ENG/Classification/ClassificationsAlphaOrder.pdf. Accessed December 20, 2017.
- Ahmadi, S.H., Haji Shabani, A.M., Dadfarnia, S., and Taei, M., Turk. J. Chem., 2007, vol. 31, p, 191.
Cited by
Patriarca, M., Barlow, N. L., Cross, A., Hill, S., Robson, A. F., Taylor, A., & Tyson, J. F. (2022) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d2ja90005j · Cited by 46
Moema, D., Makwakwa, T., Nyambaka, H. N., Dube, S., & Nindi, M. (2024) · Food Analytical Methods · doi:10.1007/s12161-024-02583-z · Cited by 19
“Similar observations were reported by other researchers (Shi et al. 2020, Pourbakhshi et al. 2021).”
Atomic Spectrometry Update: review of advances in elemental speciation
Clough, R., Harrington, C. F., Hill, S. J., Madrid, Y., & Tyson, J. F. (2022) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d2ja90029g · Cited by 18
Yan, J., Zhang, C., Wang, C., Lu, D., & Chen, S. (2022) · Talanta · doi:10.1016/j.talanta.2022.123902 · Cited by 14
Duran, C., Özdeş, D., Menteşe, E., & Bektaş, H. (2023) · Analytical Letters · doi:10.1080/00032719.2023.2203498 · Cited by 7
“…and enrichment methods including cloud point extraction (Rihana-Abdallah, Li, and Lanigan 2022; Khan et al. 2017), liquid-liquid extraction (Pourbakhshi et al. 2021), solvent free microextraction (Bahad ı r et al. 2022), two-phase extraction systems (Bulgariu et al. 2007), flotation…”
Method
Metadata
- Authors
- Pourbakhshi, Y., Heidari, M., Yahaei, E., Ghiyasi, S., Ebrahimi-Najafabadi, H., & Bozorgzadeh, E.
- Affiliations
- Guilan University of Medical Sciences (IR)
- Islamic Azad University, Tehran (IR)
- Corresponding author
- Heidari, Mahmoud
- Venue
- Journal of Analytical Chemistry
- Publisher
- Pleiades Publishing Ltd
- Published
- 2021-06
- Volume
- 76
- Issue
- 6
- Pages
- 714-720
- ISSN
- 0021-8766 (ISSN-L)
- 1061-9348
- 1608-3199
- OpenAlex
- W3167390430
- Cited by
- 10
- References
- 29
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 1 · 2022: 4
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Journal of Analytical Chemistry (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- hexavalent chromium, dispersive liquid-liquid microextraction, urine, occupational exposure, environmental exposure, biomonitoring, heavy metals, extraction solvent optimization, enrichment factor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.