Functional cardiac MRI in preterm and term newborns
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To use cardiac MRI techniques to assess ventricular function and systemic perfusion in preterm and term newborns, to compare techniques to echocardiographic methods, and to obtain initial reference data. Design: Observational magnetic resonance and echocardiographic imaging study. Setting: Neonatal Unit, Queen Charlotte's and Chelsea Hospital, London, UK. Patients: 108 newborn infants with median birth weight 1627 (580–4140) g, gestation 32 (25–42) weeks. Results: Mean (SD) flow volumes assessed by phase contrast (PC) imaging in 28 stable infants were left ventricular output (LVO) 222 (46), right ventricular output (RVO) 219 (47), superior vena cava (SVC) 95 (27) and descending aorta (DAo) 126 (32) ml/kg/min, with flow being higher at lower gestational age. Limits of agreement for repeated PC assessment of flow were LVO ±50.2, RVO ±55.5, SVC ±20.9 and DAo ±26.2 ml/kg/min. Mean (SD) LVO in 75 stable infants from three-dimensional models were 245 (47) ml/kg/min, with limits of agreement ±58.3 ml/kg/min. Limits of agreement for repeated echocardiographic assessment of LVO were ±108.9 ml/kg/min. Conclusions: Detailed magnetic resonance assessments of cardiac function and systemic perfusion are feasible in newborn infants, and provide more complete data with greater reproducibility than existing echocardiographic methods. Functional cardiac MRI could prove to be a useful research technique to study small numbers of newborn infants in specialist centres; providing insights into the pathophysiology of circulatory failure; acting as an outcome measure in clinical trials of inotropic intervention and so guiding clinical practice in the wider neonatal community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Chew, M. S., & Poelaert, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1967-9 · Cited by 151
Cited by
Echocardiographic Evaluation of Hemodynamics in Neonates and Children
Singh, Y. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00201 · Cited by 116
Ficial, B., Finnemore, A. E., Cox, D. J., Broadhouse, K. M., Price, A. N., Durighel, G., Ekitzidou, G., Hajnal, J. V., Edwards, A. D., & Groves, A. M. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.08.019 · Cited by 102
Self-citationNeonatal hemodynamics: Monitoring, data acquisition and analysis
Soleymani, S., Borzage, M., Noori, S., & Seri, I. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.32 · Cited by 23
Metadata
- Authors
- Groves, A. M., Chiesa, G., Durighel, G., Goldring, S. T., Fitzpatrick, J. A., Uribe, S., Razavi, R., Hajnal, J. V., & Edwards, A. D.
- Venue
- Archives of Disease in Childhood - Fetal and Neonatal Edition
- Publisher
- BMJ
- Published
- 2010-10-21
- Volume
- 96
- Issue
- 2
- Pages
- F86-F91
- ISSN
- 1359-2998 (ISSN-L)
- 1468-2052
- OpenAlex
- W1977858016
- Cited by
- 74
- References
- 3
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional cardiac MRI in preterm and term newborns. https://app.cochat.ai/papers/10.1136/adc.2010.189142
- The paper
- Groves, A. M., Chiesa, G., Durighel, G., Goldring, S. T., Fitzpatrick, J. A., Uribe, S., Razavi, R., Hajnal, J. V., & Edwards, A. D. (2011). Functional cardiac MRI in preterm and term newborns. Archives of Disease in Childhood - Fetal and Neonatal Edition. https://doi.org/10.1136/adc.2010.189142
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.