Overrides of medication-related clinical decision support alerts in outpatients
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index; 9 of the 19 sources its claims cite were checked for support.
Abstract
BACKGROUND: Electronic prescribing is increasingly used, in part because of government incentives for its use. Many of its benefits come from clinical decision support (CDS), but often too many alerts are displayed, resulting in alert fatigue. OBJECTIVE: To characterize the override rates for medication-related CDS alerts in the outpatient setting, the reasons cited for overrides at the time of prescribing, and the appropriateness of overrides. METHODS: We measured CDS alert override rates and the coded reasons for overrides cited by providers at the time of prescribing. RESULTS: We reviewed 157,483 CDS alerts (7.9% alert rate) on 2,004,069 medication orders during the study period. 82,889 (52.6%) of alerts were overridden. The most common alerts were duplicate drug (33.1%), patient allergy (16.8%), and drug-drug interactions (15.8%). The most likely alerts to be overridden were formulary substitutions (85.0%), age-based recommendations (79.0%), renal recommendations (78.0%), and patient allergies (77.4%).
Overview
CoChat Summary
TL;DR
In outpatient prescribing at a large academic center, providers overrode 52.6% of medication-related clinical decision support alerts, and about half of overrides were judged appropriate. Appropriateness varied widely by alert type, from 12% for renal recommendations to 92% for patient allergy alerts.
Key findings
- Of 157,483 CDS alerts generated on 2,004,069 medication orders (7.9% alert rate), 82,889 alerts (52.6%) were overridden.
- The most common alert types were duplicate drug (33.1%), patient allergy (16.8%), and drug-drug interaction (15.8%); the most frequently overridden were formulary substitutions (85.0%), age-based recommendations (79.0%), renal recommendations (78.0%), and patient allergies (77.4%).
- In a 600-override appropriateness sample, an average of 53% of overrides were appropriate, varying significantly by alert type (p<0.001) from 12% for renal recommendations to 92% for patient allergies; inter-rater reliability was κ=0.89.
- Common override reasons included “patient took previously without allergic reaction” for allergy alerts, “will monitor as recommended” for drug-drug interaction alerts (42%), and “intolerance/failure of suggested substitution” for formulary substitutions (44%).
Methods
- Retrospective analysis of CDS alert override rates and coded override reasons from outpatient clinics and ambulatory hospital-based practices at a large academic health care center over 3 years (January 1, 2009–December 31, 2011), including all provider types with prescribing authority.
- Eight alert types were studied: patient allergies, drug-drug interactions, duplicate drugs, drug-class interactions, class-class interactions, age-based recommendations, renal recommendations, and formulary substitutions.
- Primary outcome was CDS alert override rate; secondary outcomes were override rate by alert type, reasons cited at prescribing, and appropriateness of a random subset of 600 overrides, assessed using consensus criteria developed by four clinicians and analyzed with counts, percentages, and χ² tests.
Limitations
- The paper states that results come from ambulatory practices affiliated with a single large academic health care center, did not include inpatient practices, and originated from one internally developed CDS system, limiting generalizability.
- The paper states that appropriateness analysis used a randomly selected subset of overrides, did not assess patient harm, and did not examine clustering of overrides or appropriateness by provider.
- Evident from the text: appropriateness review may not capture clinical context known to prescribers, though the authors note reviewers had access to the complete electronic medical record and this likely affected only a small minority of cases.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
8 Valid · 0 Not valid · 8 Not checked · 39 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For example, the most common reason cited for overriding drug-drug interaction alerts was that the provider 'will monitor as recommended' (42%).”
§ Overrides of medication-related clinical decision support alerts in outpatients > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Formulary substitution | 15 945 | 10.1 | 13 554 | 85.0 | Intolerance/failure of suggested substitution”
§ Overrides of medication-related clinical decision support alerts in outpatients > DISCUSSION
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Providers overrode 82 889 (52.6%) of the alerts generated.”
- Also stated in: § Abstract · plain
“82 889 (52.6%) of alerts were overridden.”
§ Overrides of medication-related clinical decision support alerts in outpatients > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
- Also stated in: § Abstract · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Drug-class interaction | 19 593 | 12.4 | 4782 | 24.4 | Transitioning from one drug to the other”
§ Overrides of medication-related clinical decision support alerts in outpatients > DISCUSSION
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Renal suggestion | 3890 | 2.5 | 3035 | 78.0 | Patient has tolerated this drug in the past”
§ Overrides of medication-related clinical decision support alerts in outpatients > DISCUSSION
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
11 more claims
Create a free account to see all 55 claims and to verify the 1 reference still open.
- Probably not a substantial claim. 18
- It may state two separate claims as one. 22
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It is widely accepted that “alert fatigue” explains high override rates [7, 9–14].”
From Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system (2017) · cites this paper as [12]
Experimental — accuracy not yet measured
Citations
Cites
Kawamoto, K., Houlihan, C. A., Balas, E. A., & Lobach, D. F. (2005) · BMJ · doi:10.1136/bmj.38398.500764.8f · Cited by 2,703
Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Overriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117
Medication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763
Self-citationPhysicians' Decisions to Override Computerized Drug Alerts in Primary Care
Weingart, S. N., Toth, M., Sands, D. Z., Aronson, M. D., Davis, R. B., & Phillips, R. S. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.21.2625 · Cited by 487
Electronic Health Record Use and the Quality of Ambulatory Care in the United States
Linder, J. A., Ma, J., Bates, D. W., Middleton, B., & Stafford, R. S. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.13.1400 · Cited by 438
Self-citationImproving Acceptance of Computerized Prescribing Alerts in Ambulatory Care
Shah, N. R., Seger, A. C., Seger, D. L., Fiskio, J. M., Kuperman, G. J., Blumenfeld, B., Recklet, E. G., Bates, D. W., & Gandhi, T. K. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1868 · Cited by 353
Self-citationOverrides of Medication Alerts in Ambulatory Care
Isaac, T., Weissman, J. S., Davis, R. B., Massagli, M., Cyrulik, A., Sands, D. Z., & Weingart, S. N. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2008.551 · Cited by 309
Kesselheim, A. S., Cresswell, K., Phansalkar, S., Bates, D. W., & Sheikh, A. (2011) · Health Affairs · doi:10.1377/hlthaff.2010.1111 · Cited by 277
Self-citation
Research works printed but not linked: 1
- Nanji K, Pollard S, Bates D. Achieving meaningful use of electronic medication lists. Proceedings of AMIA Symposium. 2011:1897-8.
Cited by
Items 101–200 of 211
Impact of Definitive Drug–Drug Interaction Testing on Medication Management and Patient Care
Arnold, R. J. G., Tang, J., Schrecker, J. P., & Hild, C. (2018) · Drugs - Real World Outcomes · doi:10.1007/s40801-018-0143-z · Cited by 16
Hoffman, J. M., Flynn, A. J., Juskewitch, J. E., & Freimuth, R. R. (2020) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-020320-093614 · Cited by 21
Global Scientific Research Landscape on Medical Informatics From 2011 to 2020: Bibliometric Analysis
He, X., Peng, C., Xu, Y., Zhang, Y., & Wang, Z. (2022) · JMIR Medical Informatics · doi:10.2196/33842 · Cited by 22
Jeffries, M., Salema, N.-E., Laing, L., Shamsuddin, A., Sheikh, A., Avery, A. J., Chuter, A., Waring, J. J., & Keers, R. N. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-068798 · Cited by 19
Lilih, S., Pereboom, M., van der Hoeven, R. T. M., Mantel-Teeuwisse, A. K., & Becker, M. L. (2016) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2016.10.002 · Cited by 13
Rinner, C., Grossmann, W., Sauter, S. K., Wolzt, M., & Gall, W. (2015) · BioMed Research International · doi:10.1155/2015/380497 · Cited by 19
Wayne, M. T., Molling, D. J., Wang, X. Q., Hogan, C. K., Seelye, S. M., Liu, V. X., & Prescott, H. C. (2021) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202009-1130oc · Cited by 15
Clinician Response to Pharmacogenetic Clinical Decision Support Alerts
Lemke, L. K., Cicali, E. J., Williams, R., Nguyen, K. A., Cavallari, L. H., & Wiisanen, K. (2023) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.3051 · Cited by 18
Yang, M., Choi, S.-I., Song, W., Kim, S., Kang, H., Park, H., Cho, S., Min, K., Kim, J.-H., & Chang, Y. (2015) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2013-132538 · Cited by 14
Page, N. J. B., Baysari, M. T., & Westbrook, J. I. (2019) · Journal of Pharmacy Practice and Research · doi:10.1002/jppr.1479 · Cited by 14
High concurrent use of sulfonylureas and antimicrobials with drug interactions causing hypoglycemia
Pilla, S. J., Pitts, S. I., & Maruthur, N. M. (2022) · Journal of Patient Safety · doi:10.1097/pts.0000000000000739 · Cited by 12
Clinical Informatics in Critical Care Medicine
Nadkarni, G. N., & Sakhuja, A. (2023) · The Yale Journal of Biology and Medicine · doi:10.59249/wttu3055 · Cited by 14
Besculides, M., Mazumdar, M., Phlegar, S., Freeman, R., Wilson, S., Joshi, H., Kia, A., & Gorbenko, K. (2023) · JMIR Formative Research · doi:10.2196/42262 · Cited by 12
Meaningful time-related aspects of alerts in Clinical Decision Support Systems. A unified framework
Cánovas-Segura, B., Morales, A., Juárez, J. M., & Campos, M. (2023) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2023.104397 · Cited by 13
Ciprut, S. E., Kelly, M. D., Walter, D., Hoffman, R. T., Becker, D. J., Loeb, S., Sedlander, E., Tenner, C. T., Sherman, S. E., Zeliadt, S. B., et al. (2020) · Urology · doi:10.1016/j.urology.2020.05.101 · Cited by 12
Modulators Influencing Medication Alert Acceptance: An Explorative Review
Bittmann, J. A., Haefeli, W. E., & Seidling, H. M. (2022) · Applied Clinical Informatics · doi:10.1055/s-0042-1748146 · Cited by 18
Youssef, A., Almubarak, A., Aljohnai, M., Alnuaimi, M., Alshehri, B., Al-ghamdi, G., Akkari, K. B., & Sager, M. (2015) · Journal of Taibah University Medical Sciences · doi:10.1016/j.jtumed.2015.02.012 · Cited by 12
Kruger, J. F., Chen, A. H., Rybkin, A., Leeds, K., Guzman, D., Vittinghoff, E., & Goldman, L. (2016) · BMJ Quality & Safety · doi:10.1136/bmjqs-2015-004242 · Cited by 11
Modeling the mind: How do we design effective decision-support?
Weir, C. R., Rubin, M. A., Nebeker, J. R., & Samore, M. H. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.06.008 · Cited by 13
Hammar, T., Hellström, L., & Ericson, L. (2020) · Pharmacy · doi:10.3390/pharmacy8030118 · Cited by 14
Berger, F. A., van der Sijs, H., van Gelder, T., & van den Bemt, P. M. L. A. (2021) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098621996098 · Cited by 12
Gold, R. B., Bunce, A., Cowburn, S., Davis, J. V., Hollombe, C., Nelson, C. A., Puro, J. E., Muench, J., Hill, C., Jaworski, V., et al. (2017) · BMC Health Services Research · doi:10.1186/s12913-017-2194-3 · Cited by 12
Huang, C.-Y., Nguyen, P.-A., Yang, H., Islam, M. M., Liang, C.-W., Lee, F., & Li, Y. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.12.033 · Cited by 11
Sharpening clinical decision support alert and reminder designs with MINDSPACE: A systematic review
Hashemi, S., Bai, L., Gao, S., Burstein, F. V., & Renzenbrink, K. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105276 · Cited by 11
Harnessing the power of intelligent machines to enhance primary care
Moore, S. F., Hamilton, W. T., & Llewellyn, D. J. (2017) · British Journal of General Practice · doi:10.3399/bjgp17x693965 · Cited by 15
Monitoring clinical decision support in the electronic health record
Lam, J. H., & Ng, O. (2017) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp160819 · Cited by 12
Too many medication alerts: How alarm frequency affects providers
Fant, C. T., & Adelman, D. S. (2018) · The Nurse Practitioner · doi:10.1097/01.npr.0000544279.20257.4b · Cited by 10
Have Electronic Health Records Improved the Quality of Patient Care?
Krenn, L., & Schlossman, D. (2017) · PM&R · doi:10.1016/j.pmrj.2017.04.001 · Cited by 13
Wong, R., Mehta, T., Very, B., Luo, J., Feterik, K., Crotty, B. H., Epstein, J. A., Fliotsos, M. J., Kashyap, N., Smith, E., et al. (2022) · Journal of General Internal Medicine · doi:10.1007/s11606-022-07945-z · Cited by 13
Niazkhani, Z., Fereidoni, M., Khazaee, P. R., Shiva, A., Makhdoomi, K., Georgiou, A., & Pirnejad, H. (2020) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-01196-w · Cited by 14
Improving timeliness of hepatitis B vaccine administration in an urban safety net level III NICU
Hayashi, M., Grover, T. R., Small, S., Staples, T., & Roosevelt, G. (2021) · BMJ Quality & Safety · doi:10.1136/bmjqs-2020-012869 · Cited by 12
Habit and Automaticity in Medical Alert Override: Cohort Study
Wang, L., Goh, K. H., Yeow, A. Y. K., Poh, H. M. N., Li, K., Yeow, J. J. L., Tan, G. Y. H., & Soh, C. (2022) · Journal of Medical Internet Research · doi:10.2196/23355 · Cited by 10
Trinkley, K. E., Wright, G. C., Allen, L. A., Bennett, T. D., Glasgow, R. E., Hale, G., Heckman, S., Huebschmann, A. G., Kahn, M. G., Kao, D. P., et al. (2023) · Applied Clinical Informatics · doi:10.1055/s-0043-1775566 · Cited by 9
Health Information Technology in Long-Term Care: Potential for the Future
Little, M. O., Rantz, M., & Lynn, G. A. (2016) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2016.02.029 · Cited by 8
Usability Considerations in Oncology Electronic Medical Records
Hassett, M. J. (2017) · Journal of Oncology Practice · doi:10.1200/jop.2017.024745 · Cited by 8
Mathematical Foundations of Decision Support Systems
Spooner, S. A. (2016) · Health informatics · doi:10.1007/978-3-319-31913-1_2 · Cited by 18
Special Applications of Pharmacoepidemiology
chapter:, T. F. I. C. T. W. S. O. T., Lee, D. J., Majumdar, S. R., Lipton, H. L., Soumerai, S. B., Vellozzi, C. J., Chen, R. T., Glanz, J. M., Marinac‐Dabic, D., Normand, S. T., et al. (2013) · Wiley eBooks · doi:10.1002/9781118344828.ch22 · Cited by 8
Self-citationCordasco, K. M., Yuan, A. H., Danz, M., Jackson, L., Yee, E. F. T., Tcheung, L. S., & Washington, D. L. (2019) · Journal for Healthcare Quality · doi:10.1097/jhq.0000000000000183 · Cited by 7
Alsaidan, J., Portlock, J. C., Ata, S. I., Aljadhey, H. S., & Franklin, B. D. (2022) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-022-01838-1 · Cited by 9
Nature and management of duplicate medication alerts
Heringa, M., Floor‐Schreudering, A., Meijer, W. M., Smet, P. A. G. M. D., & Bouvy, M. L. (2015) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv021 · Cited by 7
Role of Information and Communication Technologies
Huang, A. R. (2016) · Springer eBooks · doi:10.1007/978-3-319-32304-6_19 · Cited by 7
Alert fatigue measurement in clinical decision support: a systematic review
Ray, C. E., Wilson, G., Hughes, A. M., Goedken, C. C., Liu, E. P.-F., Fitzpatrick, M. A., Suda, K. J., Kota, S. M., Nwankpa, C., & Evans, C. (2026) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocag064 · Cited by 19
Mitchell, J. D., Lenihan, D., Reed, C., Huda, A., Nolen, K. D., Bruno, M., & Kannampallil, T. (2022) · Clinical Medicine Insights: Cardiology · doi:10.1177/11795468221133608 · Cited by 6
Russ, A. L., Chen, S., Melton, B. L., Saleem, J. J., Weiner, M., Spina, J. R., Daggy, J., & Zillich, A. J. (2015) · Annals of Pharmacotherapy · doi:10.1177/1060028015581678 · Cited by 9
Prescribers’ reported acceptance and use of drug-drug interaction alerts: An Australian survey
Baysari, M. T., Dort, B. A. V., Zheng, W. Y., Li, L., Hilmer, S. N., Westbrook, J. I., & Day, R. O. (2022) · Health Informatics Journal · doi:10.1177/14604582221100678 · Cited by 7
Gedde‐Dahl, A., Spigset, O., & Molden, E. (2022) · European Journal of Clinical Pharmacology · doi:10.1007/s00228-022-03364-5 · Cited by 8
Brown, T., Zelch, B., Lee, J. Y., Doctor, J. N., Linder, J. A., Sullivan, M. D., Goldstein, N. J., Rowe, T. A., Meeker, D., Knight, T. K., et al. (2022) · Applied Clinical Informatics · doi:10.1055/s-0042-1756366 · Cited by 7
Examination of medication clinical decision support using Bayes’ theorem
Payne, T. H., & Desai, B. R. (2016) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp150964 · Cited by 8
Zhang, Y., Long, X., Chen, W., Li, H., Duan, H., & Shang, Q. (2016) · SpringerPlus · doi:10.1186/s40064-016-3701-4 · Cited by 7
Allergic Adverse Drug Events After Alert Overrides in Hospitalized Patients
de Manzanos, M. L. F., Gastaminza, G., Idoate, A., & Ortega, A. (2022) · Journal of Patient Safety · doi:10.1097/pts.0000000000001034 · Cited by 7
Using shared clinical decision support to reduce adverse drug events and improve patient safety
Ye, J., & Bronstein, S. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1703141 · Cited by 12
Decrease in use of contraindicated drugs with automated alerts in children
Song, I., Shin, H. N., & Shin, J. (2017) · Pediatrics International · doi:10.1111/ped.13258 · Cited by 7
Co, Z., Classen, D. C., Cole, J., Seger, D. L., Madsen, R., Davis, T., McGaffigan, P., & Bates, D. W. (2023) · Applied Clinical Informatics · doi:10.1055/s-0043-1777107 · Cited by 9
Self-citationCarter, B. J., Jafry, M. Z., Siddiqi, A. D., Rogova, A., Liaw, W. R., & Reitzel, L. R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824010-6.00016-2 · Cited by 10
Design and Evaluation of Trust–Eliciting Cues in Drug–Drug Interaction Alerts
Chattopadhyay, D., Verma, N., Duke, J. D., & Bolchini, D. P. (2018) · Interacting with Computers · doi:10.1093/iwc/iwx020 · Cited by 6
Idemoto, L. M., Williams, B., Ching, J. M., & Blackmore, C. C. (2015) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp140790 · Cited by 7
Khirfan, R., Kotb, H., & Atiyeh, H. M. (2024) · Research Journal of Pharmacy and Technology · doi:10.52711/0974-360x.2024.00714 · Cited by 5
Acceptance of Acute Kidney Injury Alert by Providers in Cardiac Surgery Intensive Care Unit
Nevin, C., Shawwa, K., Pincavitch, J. D., Neely, R. L., Goodwin, D., McCarthy, P. J., Mohamed, N. M., Mullett, C. J., Smith, G. S., Kellum, J. A., et al. (2022) · Applied Clinical Informatics · doi:10.1055/a-2000-7499 · Cited by 6
Parkhurst, E., Calonico, E., & Noh, G. J. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01615-5 · Cited by 5
Poly, T. N., Islam, M. M., & Li, Y. (2022) · Studies in health technology and informatics · doi:10.3233/shti220089 · Cited by 8
Chen, J., Cutrona, S. L., Dharod, A., Bunch, S. C., Foley, K. L., Ostasiewski, B., Hale, E. R., Bridges, A., Moses, A., Donny, E. C., et al. (2023) · JMIR Medical Informatics · doi:10.2196/43097 · Cited by 4
“Prior studies on alert burden focused on medication alerts and used alert override rate and alert volume as markers for burden in the context of de-implementation [30-33,40].”
BackgroundPhysician Well-being and the Future of Health Information Technology
Koon, S. (2021) · Mayo Clinic Proceedings Innovations Quality & Outcomes · doi:10.1016/j.mayocpiqo.2021.06.001 · Cited by 8
Clinical Decision Support: The Experience at Brigham and Women’s Hospital/Partners HealthCare
Varghese, P., Wright, A. T., Andersen, J. M., Yoshida, E., & Bates, D. W. (2016) · Health informatics · doi:10.1007/978-3-319-31913-1_13 · Cited by 6
Self-citationLuo, D., Ye, X., Zhao, H., et al. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2025.105960 · Cited by 3
Developing practical recommendations for drug-disease interactions in patients with hypertension
Özokcu, K., Diesveld, M. M. E., Gipmans, S. G. H., Peeters, L. E. J., van den Born, B. H., & Borgsteede, S. D. (2024) · Frontiers in Pharmacology · doi:10.3389/fphar.2024.1360146 · Cited by 8
Raven, K., Zhang, J., Vagliano, I., Jaspers, M., Peute, L., & Medlock, S. K. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2025.106011 · Cited by 5
Impact of an opioid prescribing alert system on patients with posttraumatic stress disorder
Bestha, D. P., Tomatsu, S., Hutcheson, B., Blankenship, K. M., Yu, Z., Wally, M. K., Wyatt, S. A., Seymour, R. B., Hsu, J. R., Rachal, J., et al. (2022) · American Journal on Addictions · doi:10.1111/ajad.13261 · Cited by 4
Examining medication ordering errors using AHRQ network of patient safety databases
Grauer, A., Rosen, A., Applebaum, J. R., Carter, D., Reddy, P., Col, A. K. D., Kumaraiah, D., Barchi, D. J., Classen, D. C., & Adelman, J. S. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad007 · Cited by 9
Hammar, T., Jonsén, E., Björneld, O., Askfors, Y., Andersson, M. L., & Lincke, A. (2024) · Pharmacy · doi:10.3390/pharmacy12060168 · Cited by 6
Development of a drug allergy alert tiering algorithm for penicillins and cephalosporins
Wasserman, R. L., Edrees, H. H., Seger, D. L., Goss, F. R., Blumenthal, K. G., Lo, Y.-C., Blackley, S. V., Bates, D. W., & Zhou, L. N. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2025.105789 · Cited by 3
Self-citationMoore, C. (2018) · Springer eBooks · doi:10.1007/978-3-319-71812-5_34 · Cited by 4
Bartlett, M. J., & Shephard, E. A. (2016) · Drug Metabolism and Personalized Therapy · doi:10.1515/dmpt-2015-0044 · Cited by 5
Rattanachotphanit, T., Limwattananon, C., & Waleekhachonloet, O. (2019) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098618820502 · Cited by 3
Wang, S., & Yu, L. (2025) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-025-03843-0 · Cited by 4
Barnes, G. D., Choi, S. Y., Lanham, M. S. M., Dorsch, M. P., Errickson, J., Fabbri, M., Saraswat, A. A., Seagull, F. J., & Smith, S. N. (2025) · Implementation Science · doi:10.1186/s13012-025-01478-9 · Cited by 2
Garlo, K. G., Bates, D. W., Seger, D. L., Fiskio, J. M., & Charytan, D. M. (2019) · Medicine · doi:10.1097/md.0000000000017963 · Cited by 2
Self-citationOptimization of Nursing-Specific Flu Alerts
Cieslowski, B. J., Brock, L., Richesson, R., Silva, S. G., & Kim, H. (2020) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000616 · Cited by 2
Lambert, B. L., & Schiff, G. D. (2022) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1676 · Cited by 2
Deo, R. C., Smith, R. K., MacRae, C. A., Price, E., Sheffield, H., & Patel, R. S. (2024) · SAGE Open Medicine · doi:10.1177/20503121241284025 · Cited by 2
Mathematical Model for Computer-Assisted Modification of Medication Dosing Rules
Grabel, M., Vaughan, B. L., Dexheimer, J. W., & Kirkendall, E. S. (2019) · Biomedical Informatics Insights · doi:10.1177/1178222619829079 · Cited by 3
Nguyen, T.-T., Hollands, W., & Zaiken, K. (2022) · Journal of Pharmacy Practice · doi:10.1177/08971900221079022 · Cited by 2
An interoperable electronic medical record-based platform for personalized predictive analytics
Abedtash, H. (2017) · Purdue University Indianapolis (Indiana University) · doi:10.7912/c2pp9z · Cited by 2
Gerard, E., Bugday, D., Calafiore, M., Baran, J., Gautier, S., Henry, H., Décaudin, B., Lemaître, M., Baclet, N., Quindroit, P., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0334836 · Cited by 2
Development of a hybrid artificial intelligence framework for pharmacotherapy optimization
Rose, O., Clemens, S., Leiherer, A., Bücker, M., Petersson, F., Lirk, G., Mosch, C., Pachmayr, J., & Hoti, K. (2026) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-026-02205-0 · Cited by 2
Peranan Electronic Health Record System terhadap Keselamatan Pasien di Perawatan Anak
Yayah, Y., & Rahman, L. O. A. (2020) · JIKO (Jurnal Ilmiah Keperawatan Orthopedi) · doi:10.46749/jiko.v4i1.36 · Cited by 2
Safeguarding Patient Rights and Safety in Tech-Enabled Healthcare
Aileen, J. (2025) · IGI Global eBooks · doi:10.4018/979-8-3693-7210-4.ch014 · Cited by 1
A standard-based taxonomy of features that affect user response to clinical decision support alerts
Liu, S., McCoy, A. B., Sittig, D. F., Peterson, J. F., Lasko, T. A., & Wright, A. T. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-03231-0 · Cited by 2
Muratore, S. L., Coughlan, A., Glover, J. K., Statz, C. L., Weinert, C., Kline, S. E., & Beilman, G. J. (2019) · Surgical Infections · doi:10.1089/sur.2018.228 · Cited by 1
Khalil, V., & Hua, A. (2021) · International Journal of Digital Health · doi:10.29337/ijdh.40 · Cited by 1
Moore, C. (2023) · Springer eBooks · doi:10.1007/978-3-031-29171-5_37 · Cited by 2
Special Applications of Pharmacoepidemiology
Lee, D. I., Wettermark, B., Lu, C. Y., Soumerai, S. B., Chen, R. T., Normand, S. T., Sedrakyan, A., Marinac‐Dabic, D., Horton, D. B., Hernández–Díaz, S., et al. (2021) · Wiley eBooks · doi:10.1002/9781119701101.ch23 · Cited by 2
Self-citationMaharjan, J., Thapa, R., Calvert, J. S., Attwood, M. M., Shokouhi, S., Chetty, S. C., Iqbal, Z., Singh, N. P., Arnold, R., Hoffman, J. L., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4130480 · Cited by 1
Safety Considerations in Pediatric Informatics
Spooner, S. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-31123-4_14
Modelling the Business Value of IT in Health Care: Technical and Sociotechnical Perspectives
Haddad, P., Schaffer, J. L., & Wickramasinghe, N. S. (2018) · Healthcare delivery in the information age · doi:10.1007/978-3-319-72287-0_10
Spithoff, S. M. (2019) · TSpace (University of Toronto)
Evaluating and Improving Physician Prescribing
Lu, C. Y., Majumdar, T. L. S. R., Lipton, H. L., & Soumerai, S. B. (2019) · Wiley eBooks · doi:10.1002/9781119413431.ch19
Causation of potential drug to drug interactions alerts, alert overrides, and adverse drug eventsPreprint
Ariff, A. M. M., Nalliah, S., Hadi, H. A., Win, N. T., Thoulath, M. I., Aktifanus, A. T. J., Mutaya, S. M., & Yusof, A. K. M. (2021) · Research Square · doi:10.21203/rs.3.rs-363764/v1
Autonomy vs. artificial intelligence : studies on healthcare work and analytics
Wang, L. (2021) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/146910 · Cited by 1
Yusof, M. M., Olakotan, O. O., & Puteh, S. E. W. (2019) · doi:10.2196/preprints.16809
Metadata
- Authors
- Nanji, K. C., Slight, S. P., Seger, D. L., Cho, I., Fiskio, J. M., Redden, L. M., Volk, L. A., & Bates, D. W.
- Affiliations
- Durham University (GB)
- Brigham and Women's Hospital (US)
- Corresponding author
- Nanji, Karen C
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-05
- Volume
- 21
- Issue
- 3
- Pages
- 487-491
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC3994856
- OpenAlex
- W2128688562
- Cited by
- 219
- References
- 24
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 6 · 2023: 14 · 2022: 30 · 2021: 18 · 2020: 19 · 2019: 22 · 2018: 24 · 2017: 17 · 2016: 19 · 2015: 24 · 2014: 6
- FWCI
- 28.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of the American Medical Informatics Association (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Durham Research Online (Durham University) (acceptedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- Agency for Healthcare Research and Quality (U19HS021094, 1u19hs021094-01)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- clinical decision support alerts, alert override, alarm fatigue, electronic prescribing, outpatient prescribing, drug-drug interactions
- MeSH terms
- Ambulatory Care, Drug Interactions, Drug Therapy, Computer-Assisted, Humans, Physicians, Reminder Systems, Decision Support Systems, Clinical, Medical Order Entry Systems, Electronic Prescribing, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.