Colour vision testing as an aid to diagnosis and management of age related maculopathy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
AIM: To provide a simple test that detects the onset of age related maculopathy (ARM), and can be used to monitor its severity. METHODS: Colour contrast sensitivity was measured using computer graphics techniques. Colour thresholds were measured along tritan and protan colour confusion axes in the presence of dynamic luminance noise. Thresholds were determined separately for two sizes of optotypes (6.5 degrees and 1.5 degrees). Natural pupils were used. Normal values for the test have been established. RESULTS: In all patients with unilateral age related macular degeneration, the smaller optotype was invisible in that eye and in almost all, the larger optotype could not be seen. In the symptomless fellow eyes (with ARM) the larger optotype thresholds were raised. The degree of loss was larger for tritan. For the smaller optotype, protan thresholds were elevated in the majority of patients. Tritan losses were greater and disproportionate to the loss seen with the larger optotype. Every person including those with minimal fundal changes had tritan test results for 1.5 degree optotypes >2 SD above the normal mean. Tritan thresholds varied with the severity of the ARM. CONCLUSIONS: The test is sensitive, simple and quick to administer, and easy for patients. Therefore, it should be useful in detecting and monitoring elderly people with age related changes in their fundi before irreversible loss of vision has occurred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bird, A. C., Bressler, N. M., Bressler, S. B., Chisholm, I. H., Coscas, G., Davis, M. D., de Jong, P. T. V. M., Klaver, C. C. W., Klein, B. E. K., Klein, R., et al. (1995) · Survey of Ophthalmology · doi:10.1016/s0039-6257(05)80092-x · Cited by 1,926
(2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)00967-9 · Cited by 814
Age-related changes in the central visual field for short-wavelength-sensitive pathways
Johnson, C. A., Adams, A. J., Twelker, J. D., & Quigg, J. M. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.002131 · Cited by 132
Cited by
A randomized placebo-controlled trial of idebenone in Leber’s hereditary optic neuropathy.
Klopstock, T., Yu-Wai-Man, P., Dimitriadis, K., Rouleau, J., Heck, S., Bailie, M., Atawan, A., Chattopadhyay, S., Schubert, M., Garip, A., et al. (2011) · Brain · doi:10.1093/brain/awr170 · Cited by 578
“Thirty-nine patients in Munich were also assessed for colour contrast sensitivity by determining red–green (Protan) and blue–yellow (Tritan) colour confusion using computer graphics techniques (Arden and Wolf, 2004).”
BackgroundMethodCone degeneration in aging and age-related macular degeneration
Shelley, E. J. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2008.622 · Cited by 85
Loss of chromatic sensitivity in AMD and diabetes: a comparative study
O’Neill‐Biba, M., Sivaprasad, S., Rodriguez‐Carmona, M., Wolf, J. E., & Barbur, J. L. (2010) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00775.x · Cited by 74
“Some studies have suggested that chromatic sensitivity loss can precede structural changes in the retina, when detection of such changes relies on the use of conventional fundus imaging techniques (Eisner et al., 1991, 1992; Hardy et al., 1992; Cheng and Vingrys,1993; Midena et al., 1997; Kurtenbach et al., 1999; Ong…”
BackgroundMethodInfluential
Metadata
- Authors
- Arden, G. B.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2004-09-01
- Volume
- 88
- Issue
- 9
- Pages
- 1180-1185
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2021262615
- Cited by
- 55
- References
- 3
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colour vision testing as an aid to diagnosis and management of age related maculopathy. https://app.cochat.ai/papers/10.1136/bjo.2003.033480
- The paper
- Arden, G. B. (2004). Colour vision testing as an aid to diagnosis and management of age related maculopathy. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.2003.033480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.