The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
Open accessAbstract
AIMS: To evaluate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact tonometer (NCT). METHODS: CCT was recorded for either eye (randomly selected) of each of 105 untreated patients with ocular hypertension and glaucoma attending the glaucoma research unit at Moorfields Eye Hospital. For each of the selected eyes, IOP was measured with the GAT (two observers), Tono-Pen, OBF, and NCT in a randomised order. The relation of measured IOP and of inter-tonometer differences with CCT and subject age was explored by linear regression analysis. RESULTS: A significant association between measured IOP and CCT was found with each instrument. The change in measured IOP for a 10 mum increase in CCT was 0.28, 0.31, 0.38, and 0.46 for the GAT, Tono-Pen, OBF, and NCT, respectively (all p< or = 0.05). There was a significant association between the NCT/GAT differences and CCT, with a tendency of NCT to overestimate GAT in eyes with thicker corneas. There was a significant association between GAT/Tono-Pen and OBF/Tono-Pen differences and age, with a tendency of GAT and OBF to overestimate the Tono-Pen in eyes of older subjects. CONCLUSION: IOP measurement by all four methods is affected by CCT. The NCT is affected by CCT significantly more than the GAT. Subject age has a differential effect on the IOP measurements made by the GAT and OBF compared to the Tono-Pen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
Human Corneal Thickness and Its Impact on Intraocular Pressure Measures
Doughty, M. J., & Zaman, M. L. (2000) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00110-7 · Cited by 1,362
APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS
EHLERS, N., BRAMSEN, T., & SPERLING, S. (1975) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1975.tb01135.x · Cited by 931
WOLFS, R. C. W., KLAVER, C. C. W., VINGERLING, J. R., GROBBEE, D. E., HOFMAN, A., & de JONG, P. T. V. M. (1997) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71125-0 · Cited by 415
Shimmyo, M., Ross, A. J., Moy, A., & Mostafavi, R. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00424-0 · Cited by 375
Collagen fibrils in the human corneal stroma: structure and aging.
Daxer, A., Misof, K., Grabner, B., Ettl, A. R., & Fratzl, P. (1998) · PubMed · Cited by 334
Determination of the True Intraocular Pressure and Modulus of Elasticity of the Human Cornea in vivo
Orssengo, G. (1999) · Bulletin of Mathematical Biology · doi:10.1006/bulm.1999.0102 · Cited by 304
Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry
Kaufmann, C., Bachmann, L. M., & Thiel, M. A. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0018 · Cited by 281
Ageing of the human corneal stroma: structural and biochemical changes
MALIK, N., MOSS, S., AHMED, N., FURTH, A., WALL, R., & MEEK, K. (1992) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/0925-4439(92)90041-k · Cited by 276
Central corneal thickness and intraocular pressure in a Mongolian population,
Foster, P. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)96021-3 · Cited by 271
Bhan, A., Browning, A. C., Shah, S., HAMILTON, R. D., Dave, D., & Dua, H. S. (2002) · PubMed · Cited by 254
Feltgen, N. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.1.85 · Cited by 238
Corneal Thickness and Intraocular Pressure in the Barbados Eye Studies
Nemesure, B. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.2.240 · Cited by 228
Intraocular Pressure Measurements Using Dynamic Contour Tonometry after Laser In Situ Keratomileusis
Kaufmann, C., Bachmann, L. M., & Thiel, M. A. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0946 · Cited by 214
Siganos, D. S., Papastergiou, G. I., & Moedas, C. (2004) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2003.12.033 · Cited by 170
In vitro measurement of corneal strain, thickness, and curvature using digital image processing
Hjortdal, J., & Jensen, P. K. (1995) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1995.tb00004.x · Cited by 132
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Ko, Y.-C., Liu, C.-L., & Hsu, W.-M. (2004) · Eye · doi:10.1038/sj.eye.6701458 · Cited by 119
Davey, P. G. (2004) · British Journal of Ophthalmology · doi:10.1136/bjo.2003.019331 · Cited by 102
Central Corneal Thickness, Tonometry, and Ocular Dimensions in Glaucoma and Ocular Hypertension
Singh, R. P., Goldberg, I., Graham, S. L., Sharma, A. K., & Mohsin, M. (2001) · Journal of Glaucoma · doi:10.1097/00061198-200106000-00011 · Cited by 100
Intraocular Pressure and Photorefractive Keratectomy
Garzozi, H. J., Chung, H. S., Lang, Y., Kagemann, L. E., & Harris, A. (2001) · Cornea · doi:10.1097/00003226-200101000-00006 · Cited by 86
Automatic Tonometer with Exact Theory: Various Biological Applications
Mackay, R. S., Marg, E., & Oechsli, R. (1960) · Science · doi:10.1126/science.131.3414.1668 · Cited by 67
Collagen fibrils in the human corneal stroma: structure and aging. Invest Ophthalmol Vis Sci
Daxer, A., Misof, K., Grabner, B., Ettl, A. R., & Fratzl, P. (1998) · Cited by 58
Mok, K. H. (2000) · Eye · doi:10.1038/eye.2000.108 · Cited by 46
Shimmyo, M. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.01.041 · Cited by 44
The effect of corneal thickness and corneal curvature on pneumatonometer measurements
Morgan, A. J., Harper, J., Hosking, S. L., & Gilmartin, B. (2002) · Current Eye Research · doi:10.1076/ceyr.25.2.107.10162 · Cited by 41
Cited by
Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0557 · Cited by 423
Assessment of Corneal Biomechanical Properties and Their Variation with Age
Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007) · Current Eye Research · doi:10.1080/02713680601077145 · Cited by 394
Surveillance for ocular hypertension: an evidence synthesis and economic evaluation.
Burr, J., Botello-Pinzon, P., Takwoingi, Y., Hernández, R., Vazquez-Montes, M., Elders, A., Asaoka, R., Banister, K., van der Schoot, J., Fraser, C., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16290 · Cited by 180
Metadata
- Authors
- Tonnu, P.-A.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2005-07-01
- Volume
- 89
- Issue
- 7
- Pages
- 851-854
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2101047655
- Cited by
- 357
- References
- 25
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.