CoChat

Evaluation of a hub-and-spoke model for the delivery of femtosecond laser-assisted cataract surgery within the context of a large randomised controlled trial

Open access
Roberts, Harry W, Wagh, Vijay K, Mullens, Isabella J M, Borsci, Simone, Ni, Melody Z, O’Brart, David P S · 2018 · British Journal of Ophthalmology

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Aims: To test a hypothesis that cataract operating room (OR) productivity can be improved with a femtosecond laser (FL) using a hub-and-spoke model and whether any increase in productivity can offset additional costs relating to the FL. Methods: 400 eyes of 400 patients were enrolled in a randomised-controlled trial comparing FL-assisted cataract surgery (FLACS) with conventional phacoemulsification surgery (CPS). 299 of 400 operations were performed on designated high-volume theatre lists (FLACS=134, CPS=165), where a hub-and-spoke FLACS model (1×FL, 2×ORs=2:1) was compared with independent CPS theatre lists. Details of operative timings and OR utilisation were recorded. Differences in productivity between hub-and-spoke FLACS and CPS sessions were compared using an economic model including testing hypothetical 3:1 and 4:1 models. Results: The duration of the operation itself was 12.04±4.89 min for FLACS compared with CPS of 14.54±6.1 min (P<0.001). Total patient time in the OR was reduced from 23.39±6.89 min with CPS to 20.34±5.82 min with FLACS (P<0.001)(reduction of 3.05 min per case). There was no difference in OR turnaround time between the models. Average number of patients treated per theatre list was 9 for FLACS and 8 for CPS. OR utilisation was 92.08% for FLACS and 95.83% for CPS (P<0.001). Using a previously established economic model, the FLACS service cost £144.60 more than CPS per case. This difference would be £131 and £125 for 3:1 and 4:1 models, respectively. Conclusion: The FLACS hub-and-spoke model was significantly faster than CPS, with patients spending less time in the OR. This enabled an improvement in productivity, but insufficient to meaningfully offset the additional costs relating to FLACS.

Overview

Integrity signals

Registry

Crossref · 10.1136/bjophthalmol-2017-311319

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 21 references

Cited by

See all 30

Metadata

Authors
Roberts, H. W., Wagh, V. K., Mullens, I. J. M., Borsci, S., Ni, M. Z., & O’Brart, D. P. S.
Affiliations
  • St Thomas' Hospital (GB)
  • Imperial College London (GB)
Corresponding author
Roberts, Harry W
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2018-02-07
Volume
102
Issue
11
Pages
1556-1563
ISSN
  • 0007-1161 (ISSN-L)
  • 1468-2079
OpenAlex
W2787635812
Cited by
26
References
21
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2023: 6 · 2022: 3 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 2
FWCI
5.36
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • British Journal of Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
  • University of Twente Research Information (publishedVersion, other-oa)
  • HighWire Press Open Archive (submittedVersion)
  • Spiral (Imperial College London) (submittedVersion)
  • University of Twente Research Information (submittedVersion, other-oa)
Funders
Alcon
Topics
  • Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
  • Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Quality and Management
Keywords
femtosecond laser-assisted cataract surgery, hub and spoke model, operating room productivity, phacoemulsification, surgical costs, operative time, cataract surgery
MeSH terms
Aged, Aged, 80 and over, Cataract Extraction, Female, Humans, Male, Middle Aged, Operating Rooms, Prospective Studies, Visual Acuity, Models, Organizational, Efficiency, Organizational, Models, Economic, Phacoemulsification, Pseudophakia, Lens Implantation, Intraocular, Laser Therapy, Operative Time

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a hub-and-spoke model for the delivery of femtosecond laser-assisted cataract surgery within the context of a large randomised controlled trial. https://app.cochat.ai/papers/10.1136/bjophthalmol-2017-311319
The paper
Roberts, H. W., Wagh, V. K., Mullens, I. J. M., Borsci, S., Ni, M. Z., & O’Brart, D. P. S. (2018). Evaluation of a hub-and-spoke model for the delivery of femtosecond laser-assisted cataract surgery within the context of a large randomised controlled trial. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2017-311319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.