Validity of three accelerometers during treadmill walking and motor vehicle travel
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective: To determine the relative accuracy during treadmill walking and motor vehicle travel of the ActivPAL, PALlite and Digi-Walker accelerometers. Methods: Forty healthy volunteers wearing all accelerometers undertook either five treadmill walks (n=20) at speeds ranging between 0.6 and 1.4 m/s or a 15 min motor vehicle journey (n=20). Step counts recorded by each accelerometer were compared with the actual step count determined by video analysis (treadmill walking) or with an actual step count of zero (motor vehicle). Mean percentage measurement error was calculated and compared between devices by one-way ANOVA and Student t test. Results: For treadmill walking, the measurement error was lowest for the ActivPAL, with no significant differences between the ActivPAL and the PALlite monitors. The measurement error was significantly higher for the Digi-Walker at speeds of ≤1 m/s. During vehicle travel erroneous steps were recorded by the PALlite (254 steps) and Digi-Walker (25 steps), but not the ActivPAL monitor (0 steps). Conclusions: The ActivPAL accelerometer accurately measures step count over a range of walking speeds and, unlike the other accelerometers tested, is not falsely triggered by motor vehicle travel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Methods of Measurement in epidemiology: Sedentary Behaviour
Atkin, A. J., Gorely, T., Clemes, S. A., Yates, T., Edwardson, C., Brage, S., Salmon, J., Marshall, S. J., & Biddle, S. J. (2012) · International Journal of Epidemiology · doi:10.1093/ije/dys118 · Cited by 518
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Pedometers had relatively high levels of accuracy across all speeds, but appear to be more accurate at determining step-count at higher walking speeds compared to lower walking speeds (Additional file 1: Table S11) [306, 436, 438, 439].”
BackgroundValidity of Two Wearable Monitors to Estimate Breaks from Sedentary Time
LYDEN, K., KOZEY KEADLE, S. L., STAUDENMAYER, J. W., & FREEDSON, P. S. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318260c477 · Cited by 279
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Using Cadence to Study Free-Living Ambulatory Behaviour
Tudor-Locke, C., & Rowe, D. A. (2012) · Sports Medicine · doi:10.2165/11599170-000000000-00000 · Cited by 231
Van Dijk, M. L., De Groot, R. H., Van Acker, F., Savelberg, H. H., & Kirschner, P. A. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-799 · Cited by 64
“Previous research has shown that this device is a reliable instrument with which to measure physical activity in adolescent girls [42] and young adults [43].”
BackgroundDifferent Location of Triaxial Accelerometer and Different Energy Expenditures
Kim, D. Y., Jung, Y.-S., Park, R.-W., & Joo, N.-S. (2014) · Yonsei Medical Journal · doi:10.3349/ymj.2014.55.4.1145 · Cited by 34
Metadata
- Authors
- Maddocks, M., Petrou, A., Skipper, L., & Wilcock, A.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2008-08-13
- Volume
- 44
- Issue
- 8
- Pages
- 606-608
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2155495553
- Cited by
- 64
- References
- 4
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.