Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 279

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Validity of Two Wearable Monitors to Estimate Breaks from Sedentary Time

Open access
LYDEN, KATE, KOZEY KEADLE, SARAH L., STAUDENMAYER, JOHN W., FREEDSON, PATTY S. · 2012 · Medicine & Science in Sports & Exercise

Abstract

UNLABELLED: Investigations using wearable monitors have begun to examine how sedentary time behaviors influence health. PURPOSE: The objective of this study is to demonstrate the use of a measure of sedentary behavior and to validate the activPAL (PAL Technologies Ltd., Glasgow, Scotland) and ActiGraph GT3X (Actigraph, Pensacola, FL) for estimating measures of sedentary behavior: absolute number of breaks and break rate. METHODS: Thirteen participants completed two 10-h conditions. During the baseline condition, participants performed normal daily activity, and during the treatment condition, participants were asked to reduce and break up their sedentary time. In each condition, participants wore two ActiGraph GT3X monitors and one activPAL. The ActiGraph was tested using the low-frequency extension filter (AG-LFE) and the normal filter (AG-Norm). For both ActiGraph monitors, two count cut points to estimate sedentary time were examined: 100 and 150 counts per minute. Direct observation served as the criterion measure of total sedentary time, absolute number of breaks from sedentary time, and break rate (number of breaks per sedentary hour (brk·sed-h)). RESULTS: Break rate was the only metric sensitive to changes in behavior between baseline (5.1 [3.3-6.8] brk·sed-h) and treatment conditions (7.3 [4.7-9.8] brk·sed-h) (mean (95% confidence interval)). The activPAL produced valid estimates of all sedentary behavior measures and was sensitive to changes in break rate between conditions (baseline, 5.1 [2.8-7.1] brk·sed-h; treatment, 8.0 [5.8-10.2] brk·sed-h). In general, the AG-LFE and AG-Norm were not accurate in estimating break rate or the absolute number of breaks and were not sensitive to changes between conditions. CONCLUSION: This study demonstrates the use of expressing breaks from sedentary time as a rate per sedentary hour, a metric specifically relevant to free-living behavior, and provides further evidence that the activPAL is a valid tool to measure components of sedentary behavior in free-living environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e318260c477

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 279

Metadata

Authors
LYDEN, K., KOZEY KEADLE, S. L., STAUDENMAYER, J. W., & FREEDSON, P. S.
Venue
Medicine & Science in Sports & Exercise
Published
2012-11
Volume
44
Issue
11
Pages
2243-2252
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2084529600
Cited by
279
References
27
FWCI
9.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity of Two Wearable Monitors to Estimate Breaks from Sedentary Time. https://app.cochat.ai/papers/10.1249/mss.0b013e318260c477
The paper
LYDEN, K., KOZEY KEADLE, S. L., STAUDENMAYER, J. W., & FREEDSON, P. S. (2012). Validity of Two Wearable Monitors to Estimate Breaks from Sedentary Time. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e318260c477

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.