CoChat

Time-of-day dependence of isokinetic leg strength and associated interday variability.

Open access
Wyse, J P, Mercer, T H, Gleeson, N P · 1994 · British Journal of Sports Medicine
Cited by 74

The DOI matches its Crossref record.

Abstract

The purpose of this study was to assess the interday variability and time-of-day effects on selected isokinetic leg strength indices. Nine adult collegiate sportsmen (mean(s.e.) age 19.6(0.5) years; mean(s.e.) height 1.81(0.02) m; mean(s.e.) body mass 76.5(3.1) kg) completed a series of nine test sessions, organized so that each subject was tested three times within a day (08.00-09.00 hours; 13.00-14.00 hours; 18.00-19.30 hours), on three occasions, each separated by a minimum of 7 days. Gravity-corrected indices of extension peak torque (EPT), flexion peak torque (FPT), and the peak torque ratio (PTR), at contraction velocities of 1.05 rad s-1 and 3.14 rad s-1, were calculated for each subject using an isokinetic dynamometer. Two-way repeated measures analysis of variance of coefficient of variation (V%) scores revealed no significant differences in performance variability across within-subject factors of time-of-day and performance index (P > 0.05). Overall mean(s.e.) V% for scores across experimental conditions were 3.97(0.72)% at 1.05 rad s-1 and 5.98(1.23)% at 3.14 rad s-1, suggesting that similar levels of measurement error occur between 08.00-19.30 hours. One-way repeated measures analysis of variance of absolute strength indices (EPT, FPT and PTR) revealed that significantly higher scores were achieved during session 3 (18.00-19.30 hours), with mean(s.e.) values of 249.1(40.0) N m, 149.0(32.3) N m, 59.5(5.0)% at 1.05 rad s-1, and 172.1(38.7) N m, 121.3(27.7) N m, 71.1(6.2)% at 3.14 rad s-1, respectively (P < 0.05). This finding appears to be consistent with current knowledge about time-of-day effects on the assessment of muscular strength. Thus for stable and maximal values to be obtained during isokinetic leg testing, the use of multiple-trial protocols is recommended, with testing occurring as close to 18.00-19.30 hours as possible. In addition, the observed significant time-of-day effect suggests that appropriate comparison of maximal isokinetic leg strength can only be achieved based on data obtained within 30 min of the same time of day.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjsm.28.3.167

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wyse, J. P., Mercer, T. H., & Gleeson, N. P.
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
1994-09
Volume
28
Issue
3
Pages
167-170
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W2127945518
Cited by
74
References
0
FWCI
0.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.