Extended fetal echocardiographic examination for detecting cardiac malformations in low risk pregnancies.
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To improve the rate of prenatal detection of cardiac malformations in a low risk population. DESIGN: Comparison of extended fetal echocardiography with the standard four chamber view in detecting abnormalities. Extended echocardiography comprised the four chamber view and visualisation of the left ventricular outflow tract, the right ventricular outflow tract, and the main pulmonary artery and its branches. In cases with abnormal results complete echocardiographic studies were performed by a paediatric cardiologist using M mode, Doppler, and colour flow mapping techniques. SETTING: Obstetric ultrasonographic unit at Shaare-Zedek Medical Centre, Jerusalem. SUBJECTS: 5400 fetuses in low risk pregnancies between 18 and 24 weeks' gestation (mean 21 weeks); 53 were lost to follow up. MAIN OUTCOME MEASURES: Detection of abnormality before and after birth. RESULTS: During the study 23 infants (0.4%) were born with cardiac abnormalities, 21 of whom had major structural and functional heart disease. 18 fetuses had heart disease diagnosed prenatally, 11 by the four chamber view alone (sensitivity 48%) and a further seven by extended echocardiography (sensitivity 78%). Five fetal cardiac defects were missed prenatally (false negative rate 22%). These included coarctation of aorta, persistent truncus arteriosus, tetralogy of Fallot, ventricular septal defect, and pulmonic stenosis. Only one false positive diagnosis (coarctation of aorta) was made (specificity 99.9%, false positive rate 0.1%). The abnormality was correctly identified in 17 out of 18 cases. CONCLUSIONS: The extended fetal heart examination detected 86% (18/21) of major abnormalities in a low risk population. The examination should be incorporated into routine prenatal ultrasonographic investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of serial measurements in medical research.
Matthews, J. N., Altman, D. G., Campbell, M. J., & Royston, P. (1990) · BMJ · doi:10.1136/bmj.300.6719.230 · Cited by 3,136
Statistical Theory and Methodology in Science and Engineering
Dykstra, O. (1965) · Technometrics · doi:10.1080/00401706.1965.10490280 · Cited by 807
Report of the New England Regional Infant Cardiac Program
(1980) · Pediatrics · doi:10.1542/peds.65.2.377 · Cited by 730
Congenital heart disease in a cohort of 19,502 births with long-term follow-up
Hoffman, J. I. E., & Christianson, R. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90635-5 · Cited by 548
Heart Disease in Infancy and Childhood
(1979) · Archives of Disease in Childhood · doi:10.1136/adc.54.2.168-b · Cited by 481
Copel, J. A., Pilu, G., Green, J., Hobbins, J. C., & Kleinman, C. S. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(87)80022-4 · Cited by 287
Kleinman, C. S., Hobbins, J. C., Jaffe, C. C., Lynch, D. C., & Talner, N. S. (1980) · Pediatrics · doi:10.1542/peds.65.6.1059 · Cited by 283
Echocardiographic and anatomical correlates in the fetus.
Allan, L. D., Tynan, M. J., Campbell, S., Wilkinson, J. L., & Anderson, R. H. (1980) · Heart · doi:10.1136/hrt.44.4.444 · Cited by 228
Prenatal screening for congenital heart disease.
Allan, L. D., Crawford, D. C., Chita, S. K., & Tynan, M. J. (1986) · BMJ · doi:10.1136/bmj.292.6537.1717 · Cited by 211
Paternal age and the occurrence of birth defects.
Lian, Z.-H., Zack, M. M., & Erickson, J. D. (1986) · Europe PMC (PubMed Central) · Cited by 140
Accuracy of fetal echocardiography.
Benacerraf, B. R., Pober, B. R., & Sanders, S. P. (1987) · Radiology · doi:10.1148/radiology.165.3.3685364 · Cited by 60
Cited by
Detection of Transposition of the Great Arteries in Fetuses Reduces Neonatal Morbidity and Mortality
Bonnet, D., Coltri, A., Butera, G., Fermont, L., Le Bidois, J., Kachaner, J., & Sidi, D. (1999) · Circulation · doi:10.1161/01.cir.99.7.916 · Cited by 760
ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Self-citationImproving the effectiveness of routine prenatal screening for major congenital heart defects
Carvalho, J. S., Mavrides, E., Shinebourne, E. A., Campbell, S., & Thilaganathan, B. (2002) · Heart · doi:10.1136/heart.88.4.387 · Cited by 362
Congenital Heart Defects: Natural Course and In Utero Development
Yagel, S., Weissman, A., Rotstein, Z., Manor, M., Hegesh, J., Anteby, E., Lipitz, S., & Achiron, R. (1997) · Circulation · doi:10.1161/01.cir.96.2.550 · Cited by 311
Self-citationTegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2710 · Cited by 308
Metadata
- Authors
- Achiron, R., Glaser, J., Gelernter, I., Hegesh, J., & Yagel, S.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1992-03-14
- Volume
- 304
- Issue
- 6828
- Pages
- 671-674
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W1963840286
- Cited by
- 264
- References
- 11
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.