Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 257

The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.

Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial

Open access
Duran-Cantolla, J., Aizpuru, F., Montserrat, J. M., Ballester, E., Teran-Santos, J., Aguirregomoscorta, J. I., Gonzalez, M., Lloberes, P., Masa, J. F., De La Pena, M., Carrizo, S., Mayos, M., Barbe, F., Spanish Sleep and Breathing Group · 2010 · BMJ

Abstract

OBJECTIVE: To assess the effect of continuous positive airway pressure (CPAP) on 24 hour ambulatory blood pressure monitoring values in a large number of patients with untreated systemic hypertension of new onset and obstructive sleep apnoea. DESIGN: Multicentre, double blind, randomised, placebo controlled trial. SETTING: Eleven general hospitals in Spain between 2004 and 2007. PARTICIPANTS: 340 patients recently diagnosed as having systemic hypertension by a general practitioner (systolic blood pressure ≥140 mm Hg, diastolic blood pressure ≥90 mm Hg, or both) and an apnoea-hypopnoea index per hour of sleep of >15 events/hour. INTERVENTION: Patients were assigned to CPAP (n=169) or sham CPAP (n=171) for three months. Main outcome measurements Net changes in the different 24 hour ambulatory blood pressure monitoring values from baseline to three months of optimal or sham CPAP. RESULTS: 277 (81%) of the 340 patients randomised were men; the patients had a mean age of 52.4 (SD 10.5) years, a body mass index of 31.9 (5.7), an Epworth sleepiness scale score of 10.1 (4.3), an apnoea-hypopnoea index of 43.5 (24.5). No differences between groups were seen at baseline. Compared with placebo and analysed by intention to treat, the mean 24 hour ambulatory blood pressure of the CPAP group decreased by 1.5 (95% confidence interval: 0.4 to 2.7) mm Hg (P=0.01). The mean 24 hour ambulatory blood pressure monitoring measures decreased by 2.1 mm Hg (0.4 to 3.7) mm Hg (P=0.01) for systolic pressure and 1.3 (0.2 to 2.3) mm Hg (P=0.02) for diastolic blood pressure. Mean nocturnal blood pressure decreased by 2.1 (0.5 to 3.6) mm Hg (P=0.01). CONCLUSIONS: CPAP produced a statistically significant reduction in blood pressure in patients with systemic hypertension and obstructive sleep apnoea. This reduction is small and did not achieve the 3 mm Hg drop in mean 24 hour ambulatory blood pressure that the trial was powered to detect. Consequently, these results may have uncertain clinical relevance. However, taking into account the prevalence of hypertension and the likelihood of comorbidities, the decrease in blood pressure, although minimal, may be beneficial. TRIAL REGISTRATION: Clinical trials NCT00202527.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.c5991

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 257

Metadata

Authors
Duran-Cantolla, J., Aizpuru, F., Montserrat, J. M., Ballester, E., Teran-Santos, J., Aguirregomoscorta, J. I., Gonzalez, M., Lloberes, P., Masa, J. F., De La Pena, M., Carrizo, S., Mayos, M., Barbe, F., & Spanish Sleep and Breathing Group
Venue
BMJ
Publisher
BMJ
Published
2010-11-24
Volume
341
Issue
nov24 1
Pages
c5991-c5991
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2128416574
Cited by
257
References
58
FWCI
11.41
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.