Prediction system for risk of allograft loss in patients receiving kidney transplants: international derivation and validation study

Open access
Loupy, Alexandre, Aubert, Olivier, Orandi, Babak J, Naesens, Maarten, Bouatou, Yassine, Raynaud, Marc, Divard, Gillian, Jackson, Annette M, Viglietti, Denis, Giral, Magali, Kamar, Nassim, Thaunat, Olivier, Morelon, Emmanuel, Delahousse, Michel, Kuypers, Dirk, Hertig, Alexandre, Rondeau, Eric, Bailly, Elodie, Eskandary, Farsad, Böhmig, Georg, Gupta, Gaurav, Glotz, Denis, Legendre, Christophe, Montgomery, Robert A, Stegall, Mark D, Empana, Jean-Philippe, Jouven, Xavier, Segev, Dorry L, Lefaucheur, Carmen·2019·BMJ

Abstract

Objective: To develop and validate an integrative system to predict long term kidney allograft failure. Design: International cohort study. Setting: Three cohorts including kidney transplant recipients from 10 academic medical centres from Europe and the United States. Participants: Derivation cohort: 4000 consecutive kidney recipients prospectively recruited in four French centres between 2005 and 2014. Validation cohorts: 2129 kidney recipients from three centres in Europe and 1428 from three centres in North America, recruited between 2002 and 2014. Additional validation in three randomised controlled trials (NCT01079143, EudraCT 2007-003213-13, and NCT01873157). Main outcome measure: Allograft failure (return to dialysis or pre-emptive retransplantation). 32 candidate prognostic factors for kidney allograft survival were assessed. Results: Among the 7557 kidney transplant recipients included, 1067 (14.1%) allografts failed after a median post-transplant follow-up time of 7.12 (interquartile range 3.51-8.77) years. In the derivation cohort, eight functional, histological, and immunological prognostic factors were independently associated with allograft failure and were then combined into a risk prediction score (iBox). This score showed accurate calibration and discrimination (C index 0.81, 95% confidence interval 0.79 to 0.83). The performance of the iBox was also confirmed in the validation cohorts from Europe (C index 0.81, 0.78 to 0.84) and the US (0.80, 0.76 to 0.84). The iBox system showed accuracy when assessed at different times of evaluation post-transplant, was validated in different clinical scenarios including type of immunosuppressive regimen used and response to rejection therapy, and outperformed previous risk prediction scores as well as a risk score based solely on functional parameters including estimated glomerular filtration rate and proteinuria. Finally, the accuracy of the iBox risk score in predicting long term allograft loss was confirmed in the three randomised controlled trials. Conclusion: An integrative, accurate, and readily implementable risk prediction score for kidney allograft failure has been developed, which shows generalisability across centres worldwide and common clinical scenarios. The iBox risk prediction score may help to guide monitoring of patients and further improve the design and development of a valid and early surrogate endpoint for clinical trials. Trial registration: Clinicaltrials.gov NCT03474003.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.l4923

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 350

Metadata

Authors
Loupy, A., Aubert, O., Orandi, B. J., Naesens, M., Bouatou, Y., Raynaud, M., Divard, G., Jackson, A. M., Viglietti, D., Giral, M., Kamar, N., Thaunat, O., Morelon, E., Delahousse, M., Kuypers, D., Hertig, A., Rondeau, E., Bailly, E., Eskandary, F., Böhmig, G., Gupta, G., Glotz, D., Legendre, C., Montgomery, R. A., Stegall, M. D., Empana, J.-P., Jouven, X., Segev, D. L., & Lefaucheur, C.
Venue
BMJ
Publisher
BMJ
Published
2019-09-17
Volume
366
Pages
l4923
ISSN
  • 1756-1833 (ISSN-L)
  • 0959-8138
OpenAlex
W2974347135
Cited by
350
References
28
FWCI
36.27
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction system for risk of allograft loss in patients receiving kidney transplants: international derivation and validation study. https://app.cochat.ai/papers/10.1136/bmj.l4923
The paper
Loupy, A., Aubert, O., Orandi, B. J., Naesens, M., Bouatou, Y., Raynaud, M., Divard, G., Jackson, A. M., Viglietti, D., Giral, M., Kamar, N., Thaunat, O., Morelon, E., Delahousse, M., Kuypers, D., Hertig, A., Rondeau, E., Bailly, E., Eskandary, F., . . . Lefaucheur, C. (2019). Prediction system for risk of allograft loss in patients receiving kidney transplants: international derivation and validation study. BMJ. https://doi.org/10.1136/bmj.l4923

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.