CoChat

Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit

Open access
Kosiborod, Mikhail, Gottlieb, Rebecca K, Sekella, Julie A, Peterman, Diane, Grodzinsky, Anna, Kennedy, Paul, Borkon, Michael A · 2014 · BMJ Open Diabetes Research & Care
Cited by 47

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Maintaining glucose in the target range, while avoiding hypoglycemia, is challenging in critically ill patients. We investigated the performance and safety of Medtronic Sentrino, a newly developed continuous glucose management (CGM) system for critically ill adults. Methods: This was a prospective, single-center, single-arm, open-label study in adult patients with cardiac ICU admission. Sentrino subcutaneous glucose sensors were inserted into patients’ thigh with planned study participation of 72 h. Sensor glucose results were displayed, and the system's alerts and alarms fully enabled. Reference blood glucose was collected from central venous catheter and analyzed with a blood gas analyzer. Treatment decisions were made independently of sensor glucose values, according to the existing standard of care. Results: A total of 21 patients were enrolled; all successfully completed the study. Sensor glucose values were displayed 96% of the time, and 870 paired blood glucose–sensor glucose points were analyzed. Overall mean absolute relative difference (MARD) was 12.8% (95% CI 11.9% to 13.6%). No clinically significant differences in accuracy were seen within subgroups of hemodynamic status (MARD 12.3% and 13.1% for compromised vs stable hemodynamics). Consensus grid analysis showed >99% of sensor glucose values within A/B zones. No device or study-related adverse events were reported. 100% of clinicians found Sentrino easy to use after two patients. Conclusions: In our single-center experience, Sentrino CGM system demonstrated good accuracy and reliability, with no device-related adverse events in critically ill cardiac patients, and was easy to use and integrate in the cardiac ICU. Trial registration number: NCT01763567.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmjdrc-2014-000037

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 47

Metadata

Authors
Kosiborod, M., Gottlieb, R. K., Sekella, J. A., Peterman, D., Grodzinsky, A., Kennedy, P., & Borkon, M. A.
Venue
BMJ Open Diabetes Research & Care
Publisher
BMJ
Published
2014-07
Volume
2
Issue
1
Pages
e000037
ISSN
2052-4897 (ISSN-L)
OpenAlex
W2139869529
Cited by
47
References
2
FWCI
5.27
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit. https://app.cochat.ai/papers/10.1136/bmjdrc-2014-000037
The paper
Kosiborod, M., Gottlieb, R. K., Sekella, J. A., Peterman, D., Grodzinsky, A., Kennedy, P., & Borkon, M. A. (2014). Performance of the Medtronic Sentrino continuous glucose management (CGM) system in the cardiac intensive care unit. BMJ Open Diabetes Research & Care. https://doi.org/10.1136/bmjdrc-2014-000037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.