Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Objective: New electronic devices offer an opportunity within routine primary care settings for improving the detection of atrial fibrillation (AF), which is a common cardiac arrhythmia and a modifiable risk factor for stroke. We aimed to assess the performance of a modified blood pressure (BP) monitor and two single-lead ECG devices, as diagnostic triage tests for the detection of AF. Setting: 6 General Practices in the UK. Participants: 1000 ambulatory patients aged 75 years and over. Primary and secondary outcome measures: Comparative diagnostic accuracy of modified BP monitor and single-lead ECG devices, compared to reference standard of 12-lead ECG, independently interpreted by cardiologists. Results: A total of 79 participants (7.9%) had AF diagnosed by 12-lead ECG. All three devices had a high sensitivity (93.9–98.7%) and are useful for ruling out AF. WatchBP is a better triage test than Omron autoanalysis because it is more specific—89.7% (95% CI 87.5% to 91.6%) compared to 78.3% (95% CI 73.0% to 82.9%), respectively. This would translate into a lower follow-on ECG rate of 17% to rule in/rule out AF compared to 29.7% with the Omron text message in the study population. The overall specificity of single-lead ECGs analysed by a cardiologist was 94.6% for Omron and 90.1% for Merlin. Conclusions: WatchBP performs better as a triage test for identifying AF in primary care than the single-lead ECG monitors as it does not require expertise for interpretation and its diagnostic performance is comparable to single-lead ECG analysis by cardiologists. It could be used opportunistically to screen elderly patients for undiagnosed AF at regular intervals and/or during BP measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Kearley K et al16 showed similar results in a large study among elderly age group (sensitivity‐98.7% and specificity‐76.2%).”
From Portable out-of-hospital electrocardiography: A review of current technologies (2018) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lozano, R., Naghavi, M., Foreman, K., Lim, S., Shibuya, K., Aboyans, V., Abraham, J., Adair, T., Aggarwal, R., Ahn, S. Y., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61728-0 · Cited by 14,070
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
The Framingham Study: The Epidemiology of Atherosclerotic Disease
Dawber, T. R. (1980) · Harvard University Press eBooks · doi:10.4159/harvard.9780674492097 · Cited by 1,454
2012 Focused Update of the ESC Guidelines for the Management of Atrial Fibrillation
Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., & Kirchhof, P. (2013) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2012.11.003 · Cited by 687
Hobbs, F., Fitzmaurice, D., Mant, J., Murray, E., Jowett, S., Bryan, S., Raftery, J., Davies, M., & Lip, G. (2005) · Health Technology Assessment · doi:10.3310/hta9400 · Cited by 437
Self-citationMortality Trends in Patients Diagnosed With First Atrial Fibrillation
Miyasaka, Y., Barnes, M. E., Bailey, K. R., Cha, S. S., Gersh, B. J., Seward, J. B., & Tsang, T. S. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.062 · Cited by 411
Research works printed but not linked: 1
- 19. Macaskill P, Gatsonis C, Deeks J, et al. Chapter 10: analysing and presenting results. In: Deeks JJ, Bossuyt PM, Gatsonis C, eds. Cochrane handbook for systematic reviews of diagnostic test accuracy version 1.0. The Cochrane Collaboration, 2010:1-61.
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Self-citationMairesse, G. H., Moran, P., Van Gelder, I. C., Elsner, C., Rosenqvist, M., Mant, J., Banerjee, A., Gorenek, B., Brachmann, J., Varma, N., et al. (2017) · EP Europace · doi:10.1093/europace/eux177 · Cited by 250
Krittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00445-9 · Cited by 234
Portable out-of-hospital electrocardiography: A review of current technologies
Bansal, A., & Joshi, R. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12035 · Cited by 174
Screening for Atrial Fibrillation: US Preventive Services Task Force Recommendation Statement
US Preventive Services Task Force, Davidson, K. W., Barry, M. J., Mangione, C. M., Cabana, M., Caughey, A. B., Davis, E. M., Donahue, K. E., Doubeni, C. A., Epling, J. W., et al. (2022) · JAMA · doi:10.1001/jama.2021.23732 · Cited by 163
Stergiou, G. S., Parati, G., Vlachopoulos, C., Achimastos, A., Andreadis, E., Asmar, R., Avolio, A., Benetos, A., Bilo, G., Boubouchairopoulou, N., et al. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000969 · Cited by 148
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis
Welton, N. J., McAleenan, A., Thom, H. H., Davies, P., Hollingworth, W., Higgins, J. P., Okoli, G., Sterne, J. A., Feder, G., Eaton, D., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21290 · Cited by 141
Kotecha, D., BREITHARDT, G. E., Camm, A. J., Lip, G. Y. H., Schotten, U., Ahlsson, A., Arnar, D. O., Atar, D., Auricchio, A., Bax, J. J., et al. (2018) · EP Europace · doi:10.1093/europace/eux318 · Cited by 126
Kaasenbrood, F., Hollander, M., Rutten, F. H., Gerhards, L. J., Hoes, A. W., & Tieleman, R. G. (2016) · Europace · doi:10.1093/europace/euv426 · Cited by 119
Taggar, J. S., Coleman, T., Lewis, S., Heneghan, C., & Jones, M. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487315611347 · Cited by 105
Self-citationPopulation-Based Screening for Atrial Fibrillation
Khurshid, S., Healey, J. S., McIntyre, W. F., & Lubitz, S. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316341 · Cited by 101
Machine learning detection of Atrial Fibrillation using wearable technology
Lown, M. T., Brown, M. E., Brown, C., YUE, A. M., Shah, B. N., Corbett, S. J., Lewith, G. T., Stuart, B. L., Moore, M. V., & Little, P. S. (2020) · PLoS ONE · doi:10.1371/journal.pone.0227401 · Cited by 91
Verberk, W. J., Omboni, S., Kollias, A., & Stergiou, G. S. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.10.182 · Cited by 84
Wiesel, J., Arbesfeld, B., & Schechter, D. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.07.016 · Cited by 80
Chan, P.-H., Wong, C.-K., Pun, L., Wong, Y.-F., Wong, M. M.-Y., Chu, D. W.-S., & Siu, C.-W. (2017) · Circulation · doi:10.1161/circulationaha.116.024439 · Cited by 79
Faruk, N., Abdulkarim, A., Emmanuel, I., Folawiyo, Y. Y., Adewole, K. S., Mojeed, H. A., Oloyede, A. A., Olawoyin, L. A., Sikiru, I. A., Nehemiah, M., et al. (2021) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2021.02.007 · Cited by 78
JCS/JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia
Takase, B., Ikeda, T., Shimizu, W., Abe, H., Aiba, T., Chinushi, M., Koba, S., KUSANO, K. F., Niwano, S., Takahashi, N., et al. (2023) · Circulation Journal · doi:10.1253/circj.cj-22-0827 · Cited by 76
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Stergiou, G. S., Kyriakoulis, K. G., Stambolliu, E., Destounis, A., Karpettas, N., Kalogeropoulos, P., & Kollias, A. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002201 · Cited by 67
Kahwati, L. C., Asher, G. N., Kadro, Z. O., Keen, S., Ali, R., Coker‐Schwimmer, E., & Jonas, D. E. (2022) · JAMA · doi:10.1001/jama.2021.21811 · Cited by 66
How will machine learning inform the clinical care of atrial fibrillation?
Siontis, K. C., Yao, X., Pirruccello, J. P., Philippakis, A. A., & Noseworthy, P. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316401 · Cited by 61
A Review of Atrial Fibrillation Detection Methods as a Service
Faust, O., Ciaccio, E. J., & Acharya, U. R. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17093093 · Cited by 62
Chan, P.-H., Wong, C.-K., Pun, L., Wong, Y.-F., Wong, M. M.-Y., Chu, D. W.-S., & Siu, C.-W. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-013685 · Cited by 58
2021 Asia Pacific Heart Rhythm Society (APHRS) practice guidance on atrial fibrillation screening
Chan, N., Orchard, J. J., Agbayani, M. F., Boddington, D., Chao, T., Johar, S., John, B., Joung, B., Krishinan, S., Krittayaphong, R., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12669 · Cited by 57
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12795 · Cited by 54
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Clark, C. E., McDonagh, S. T. J., & McManus, R. J. (2019) · Journal of Human Hypertension · doi:10.1038/s41371-018-0153-z · Cited by 49
“More recently, automated BP devices are incorporating algorithms for the detection of AF [18–23]; one (Microlife WatchBP Home A device) being the subject of a positive National Institute for Health and Care Excellence NICE clinical guidelines - author listed as (NICE) Technology Appraisal [19, 24].”
MethodScreening for Atrial Fibrillation Using Economical and Accurate Technology (From the SAFETY Study)
Lown, M. T., YUE, A. M., Shah, B. N., Corbett, S. J., Lewith, G. T., Stuart, B. L., Garrard, J., Brown, M. E., Little, P. S., & Moore, M. V. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.07.003 · Cited by 47
Rhythm-based heartbeat duration normalization for atrial fibrillation detection
Islam, M. S., Ammour, N., Alajlan, N., & Aboalsamh, H. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.03.015 · Cited by 46
Gelder, I. C. V., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., Potter, T. J. R. D., Dwight, J., Guasti, L., Hanke, T., et al. (2025) · Giornale Ialiano di Cardiologia · doi:10.1714/4419.44150 · Cited by 42
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12461 · Cited by 40
Mobile Health for Arrhythmia Diagnosis and Management
Baman, J. R., Mathew, D. T., Jiang, M. N., & PASSMAN, R. S. (2021) · Journal of General Internal Medicine · doi:10.1007/s11606-021-07007-w · Cited by 40
Orchard, J., Li, J., Gallagher, R., Freedman, B., Lowres, N., & Neubeck, L. (2019) · BMC Family Practice · doi:10.1186/s12875-019-1058-9 · Cited by 36
Skála, T., Vícha, M., Rada, M., Vácha, J., Flašík, J., & Táborský, M. (2022) · Cor et Vasa · doi:10.33678/cor.2022.083 · Cited by 35
Omboni, S., & Verberk, W. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010745 · Cited by 34
Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review
Kane, S. A., Blake, J. R., McArdle, F., Langley, P., & Sims, A. J. (2016) · Open Heart · doi:10.1136/openhrt-2015-000362 · Cited by 34
Quinn, F. R., Gladstone, D. J., Ivers, N. M., Sandhu, R. K., Dolovich, L. R., Ling, A. L. H., Nakamya, J., Ramasundarahettige, C. F., Frydrych, P. A., Henein, S., et al. (2018) · CMAJ Open · doi:10.9778/cmajo.20180001 · Cited by 29
Veltmann, C., Ehrlich, J. R., Gassner, U. M., Meder, B., Möckel, M., Radke, P. W., Scholz, E., Schneider, H., Stellbrink, C., & Duncker, D. (2021) · Der Kardiologe · doi:10.1007/s12181-021-00488-3 · Cited by 26
Fay, M., Fitzmaurice, D. A., & Freedman, B. (2017) · European Journal of General Practice · doi:10.1080/13814788.2017.1374366 · Cited by 24
Self-citationWiesel, J., & Salomone, T. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.07.016 · Cited by 23
JCS / JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia
Takase, B., Ikeda, T., Shimizu, W., Abe, H., Aiba, T., Chinushi, M., Koba, S., KUSANO, K. F., Niwano, S., Takahashi, N., et al. (2024) · Journal of Arrhythmia · doi:10.1002/joa3.13052 · Cited by 24
Screening for Atrial Fibrillation using Economical and accurate TechnologY (SAFETY)—a pilot study
Lown, M. T., YUE, A. M., Lewith, G. T., Little, P. S., & Moore, M. V. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-013535 · Cited by 23
To Screen or Not to Screen? Examining the Arguments Against Screening for Atrial Fibrillation
Neubeck, L., Orchard, J. J., Lowres, N., & Freedman, S. B. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.05.118 · Cited by 23
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab001 · Cited by 22
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.11.004 · Cited by 19
Hibbitt, K., Brimicombe, J. D., Cowie, M., Dymond, A., Freedman, B., Griffin, S. J., Hobbs, R. F., Lindén, H. C., Lip, G. Y. H., Mant, J., et al. (2024) · EP Europace · doi:10.1093/europace/euae181 · Cited by 18
Chambers, D., Booth, A., Baxter, S. K., Johnson, M., Dickinson, K. C., & Goyder, E. (2016) · Health Services and Delivery Research · doi:10.3310/hsdr04350 · Cited by 20
Islam, M. S., Ismail, M. M. B., Bchir, O., Zakariah, M., & Alotaibi, Y. A. (2019) · IEEE Access · doi:10.1109/access.2019.2933507 · Cited by 17
Senoo, K., Miki, T., Okura, T., Shiraishi, H., Shirayama, T., Inoue, K., Sakatani, T., Kakita, K., Hattori, T., Nakai, K., et al. (2020) · Circulation Reports · doi:10.1253/circrep.cr-20-0032 · Cited by 17
Insights into the Role of Galectin-3 as a Diagnostic and Prognostic Biomarker of Atrial Fibrillation
Kia, Y. M., Cannavò, A., Bahiraie, P., Alilou, S., Saeedian, B., Babajani, N., Ghondaghsaz, E., Khalaji, A., & Behnoush, A. H. (2023) · Disease Markers · doi:10.1155/2023/2097012 · Cited by 16
Banerjee, A. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1548554 · Cited by 16
Islam, M. S., Ammour, N., & Alajlan, N. (2017) · International Conference on Informatics, Health & Technology (ICIHT) · doi:10.1109/iciht.2017.7899003 · Cited by 16
Palà, E., Bustamante, A., Clua‐Espuny, J. L., Acosta, J., González-Loyola, F., Santos, S. D., Ribas-Seguí, D., Ballesta-Ors, J., Peñalba, A., Giralt, M., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273571 · Cited by 15
Hybrid Decision Support to Monitor Atrial Fibrillation for Stroke Prevention
Lei, N., Kareem, M., Moon, S. K., Ciaccio, E. J., Acharya, U. R., & Faust, O. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020813 · Cited by 15
Huang, D., Cheng, Y., Chan, P., Hai, J. J., Yiu, K., Tse, H., Wong, K.-L., Fan, K., Li, A., Ng, W. L., et al. (2018) · ERJ Open Research · doi:10.1183/23120541.00135-2017 · Cited by 14
Bacchini, M., Bonometti, S., Zotti, F. D., Lechi, A., Realdon, F., Fava, C., & Minuz, P. (2019) · High Blood Pressure & Cardiovascular Prevention · doi:10.1007/s40292-019-00334-4 · Cited by 14
Chen, Y., Lei, L., & Wang, J. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.13081 · Cited by 13
Quantifying Time in Atrial Fibrillation and the Need for Anticoagulation
Miyazawa, K., Pastori, D., & Lip, G. Y. H. (2017) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2017.12.002 · Cited by 13
Identification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation
Halvaei, H., Svennberg, E., Sörnmo, L., & Stridh, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.672875 · Cited by 13
Mobile health technologies in the diagnosis and management of atrial fibrillation
PASSMAN, R. S. (2021) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000930 · Cited by 13
Jatau, A. I., Bereznicki, L., Wimmer, B. C., Bezabhe, W. M. M., & Peterson, G. M. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19116860 · Cited by 13
Screening for undiagnosed atrial fibrillation
Sandhu, R. K., & Healey, J. S. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2018.1496018 · Cited by 13
NICE atrial fibrillation guideline snubs wearable technology: a missed opportunity?
Gala, A. R. P. B. E., Pope, M., Leo, M., Lobban, T., & Betts, T. R. (2022) · Clinical Medicine · doi:10.7861/clinmed.2021-0436 · Cited by 13
Grubb, N. R., Elder, D. H. J., Broadhurst, P., Reoch, A., Tassie, E., & Neilson, A. R. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.03.062 · Cited by 12
New Technologies for Detection and Management of Atrial Fibrillation
Hamad, A. K. (2021) · Journal of the Saudi Heart Association · doi:10.37616/2212-5043.1256 · Cited by 12
Miyazawa, K., Kondo, Y., Nakano, M., Esteve‐Pastor, M. A., Rivera‐Caravaca, J. M., Senoo, K., Kobayashi, Y., & Lip, G. Y. H. (2018) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2018.02.019 · Cited by 12
Sattar, Y., Song, D. D., Sarvepalli, D., Zaidi, S. R., Ullah, W., Arshad, J., Mir, T., Zghouzi, M., Elgendy, I. Y., Qureshi, W., et al. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-01068-x · Cited by 11
Santala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Väliaho, E., Rantula, O., Naukkarinen, N. S., Hartikainen, J. E. K., Martikainen, T. J., et al. (2023) · Cardiology in Review · doi:10.1097/crd.0000000000000526 · Cited by 11
Kyriakoulis, K. G., Κόλλιας, Α., Menti, A., Chardouvelis, P., & Stergiou, G. S. (2024) · Hypertension · doi:10.1161/hypertensionaha.123.22563 · Cited by 11
Blood pressure in patients with atrial fibrillation: part 2—treatment
Cohen, D. L., & Townsend, R. R. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12939 · Cited by 11
Huppertz, N., Lip, G. Y. H., & Lane, D. A. (2019) · Clinical Research in Cardiology · doi:10.1007/s00392-019-01567-y · Cited by 11
Blood Pressure in Patients With Atrial Fibrillation: Part 1––Measurement
Cohen, D. L., & Townsend, R. R. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12905 · Cited by 10
Multiscale dilated convolutional neural network for Atrial Fibrillation detection
Xia, L., He, S., Huang, Y.-F., & Ma, H. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301691 · Cited by 9
The future of long‐term monitoring after catheter and surgical ablation for atrial fibrillation
Baman, J. R., & PASSMAN, R. S. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15375 · Cited by 8
Pulse wave parameters in assessment of left ventricular systolic function
Sagirova, Z. N., Kuznetsova, N., Larionov, V. B., Chomakhidze, P. S., Kopylov, F. Y., & Al, S. (2020) · Russian Journal of Cardiology and Cardiovascular Surgery · doi:10.17116/kardio202013031253 · Cited by 8
Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements
Lowe, A., Oh, T., & Stewart, R. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2869609 · Cited by 8
Varma, N., Cygankiewicz, I., & Turakhia, M. P. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4420 · Cited by 7
Park, S.-H., June, K. J., & Choi, Y.-K. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1620102 · Cited by 6
Mittal, A. K., Elkaldi, Y., Shih, S. R., Nathu, R., & Segal, M. S. (2024) · JMIR Research Protocols · doi:10.2196/52647 · Cited by 6
Research into practice: management of atrial fibrillation in general practice
Fitzmaurice, D. A., & Hobbs, R. F. (2014) · British Journal of General Practice · doi:10.3399/bjgp14x682057 · Cited by 6
Self-citationScreening for Atrial Fibrillation and the Role of Digital Health Technologies
Richardson, E., Hall, A., & Mitchell, A. R. J. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.88660 · Cited by 6
Szabó, A., & Ábel, K. E. (2023) · Biologia Futura · doi:10.1007/s42977-023-00175-2 · Cited by 5
Wander, G. S., McDonagh, S. T. J., Rao, M. S., Alagesan, R., Mohan, J. C., Bhagwat, A. R., Pancholia, A. K., Viswanathan, M. K., Chopda, M., Purnanand, A., et al. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14497 · Cited by 5
Atrial Fibrillation Population Screening
Gruwez, H., Proesmans, T., Evens, S., Verbrugge, F. H., Deferm, S., Dauw, J., Willems, R., Vandervoort, P. M., Haemers, P., & Pison, L. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.009 · Cited by 5
Tang, E. W. L., Yip, B. H. K., Yu, C., Wong, S. Y. S., & Lee, E. K. P. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.956542 · Cited by 5
Stroke prevention in atrial fibrillation: we can do better
Kearney, M., Fay, M., & Fitzmaurice, D. A. (2016) · British Journal of General Practice · doi:10.3399/bjgp16x683557 · Cited by 5
Self-citationMcDonagh, S. T. J., Norris, B., Fordham, A. J., Greenwood, M. R., Richards, S. H., Campbell, J. L., & Clark, C. E. (2022) · BJGP Open · doi:10.3399/bjgpo.2021.0242 · Cited by 4
A programme for early diagnosis of atrial fibrillation: a multi-centre study in primary care
Cabrera, J. D., Fluxà, G., Fuentes, C., Hoyo, J., Navarro, M., Sant, E., de la Poza, M. A., Altés, A., Duch, N., Caubet, M., et al. (2021) · Family Practice · doi:10.1093/fampra/cmab057 · Cited by 4
Accuracy of pulse interval timing in ambulatory blood pressure measurement
Kane, S. A., Blake, J. R., McArdle, F., Langley, P., & Sims, A. J. (2016) · Scientific Reports · doi:10.1038/srep37472 · Cited by 4
Screening for Atrial Fibrillation in Community and Primary Care Settings: A Scoping Review
Lakkireddy, D. (2021) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2452 · Cited by 4
Cheung, A. J., & Cheung, B. M. Y. (2015) · BMJ Case Reports · doi:10.1136/bcr-2014-207974 · Cited by 4
Janik, M. J., Raad, G., Nijmeh, G., O’Steen, M., & Rasmussen, J. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.04.086 · Cited by 3
Wander, G. S., McDonagh, S. T. J., Rao, M. S., Alagesan, R., Mohan, J., Bhagwat, A. R., Pancholia, A., Viswanathan, M., Chopda, M., Purnanand, A., et al. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14456 · Cited by 3
Lin, T., Wang, C., Liao, M., & Lai, C. (2018) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0000000000000486 · Cited by 3
Joung, B., Krittayaphong, R., Guo, Y., Yang, P., Hsieh, Y., Ikeda, T., Kim, D., Kojodjojo, P., Chan, N., Yuniadi, Y., et al. (2026) · Journal of Arrhythmia · doi:10.1002/joa3.70495 · Cited by 2
Techniques for Measuring Blood Pressure in the Office Setting
Myers, M. G., & Kaczorowski, J. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-39599-9_2 · Cited by 1
Is Screening for Atrial Fibrillation and Its Risk Factors Useful and Cost-Effective?
Sandhu, R. K., & Healey, J. S. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2020.10.009 · Cited by 1
Top Portable ECGs in the Status Quo
Chellarapu, S. A., & Cavanaugh, C. (2023) · Journal of Student Research · doi:10.47611/jsrhs.v11i1.2494 · Cited by 1
Metadata
- Authors
- Kearley, K., Selwood, M., Van den Bruel, A., Thompson, M., Mant, D., Hobbs, F. R., Fitzmaurice, D., & Heneghan, C.
- Affiliations
- University of Oxford (GB)
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
- University of Washington (US)
- University of Birmingham (GB)
- Corresponding author
- Thompson, Matthew
- Venue
- BMJ Open
- Publisher
- BMJ
- Published
- 2014-04
- Volume
- 4
- Issue
- 5
- Pages
- e004565
- ISSN
- 2044-6055 (ISSN-L)
- PMC
- PMC4025411
- OpenAlex
- W2161884253
- Semantic Scholar
- 2319f3aeb39593fd2ebff43f20bb2d74e537e1dc
- Cited by
- 106
- References
- 28
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 8 · 2023: 5 · 2022: 12 · 2021: 19 · 2020: 7 · 2019: 10 · 2018: 10 · 2017: 12 · 2016: 13 · 2015: 3 · 2014: 3
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- BMJ Open (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- National Institute for Health and Care Research (NF-SI-0611-10273, RP-PG-0407-10347)
- Programme Grants for Applied Research
- NIHR School for Primary Care Research
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Health Promotion and Cardiovascular Prevention
- Keywords
- atrial fibrillation, triage test, single-lead ECG, blood pressure monitors, diagnostic accuracy, primary care, elderly patients, stroke risk, arrhythmia screening, 12-lead ECG
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Blood Pressure Determination, Electrocardiography, Female, Humans, Male, Primary Health Care, Triage, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.