CoChat

Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography?

Open access
Dawson, Arthur, Loving, Richard T, Gordon, Robert M, Abel, Susan L, Loewy, Derek, Kripke, Daniel F, Kline, Lawrence E · 2015 · BMJ Open
Cited by 49

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Objectives: In its guidelines on the use of portable monitors to diagnose obstructive sleep apnoea, the American Academy of Sleep Medicine endorses home polygraphy with type III devices recording at a minimum airflow the respiratory effort and pulse oximetry, but advises against simple pulse oximetry. However, oximetry is widely available and simple to use in the home. This study was designed to compare the ability of the oxygen desaturation index (ODI) based on oximetry alone with a stand-alone pulse oximeter (SPO) and from the oximetry channel of the ApneaLink Plus (ALP), with the respiratory disturbance index (RDI) based on four channels from the ALP to predict the apnoea–hypopnoea index (AHI) from laboratory polysomnography. Design: Cross-sectional diagnostic accuracy study. Setting: Sleep medicine practice of a multispecialty clinic. Participants: Patients referred for laboratory polysomnography with suspected sleep apnoea. We enrolled 135 participants with 123 attempting the home sleep testing and 73 having at least 4 hours of satisfactory data from SPO and ALP. Interventions: Participants had home testing performed simultaneously with both a SPO and an ALP. The 2 oximeter probes were worn on different fingers of the same hand. The ODI for the SPO was calculated using Profox software (ODI SOX ). For the ALP, RDI and ODI were calculated using both technician scoring (RDI MAN and ODI MAN ) and the ALP computer scoring (RDI RAW and ODI RAW ). Results: The receiver–operator characteristic areas under the curve for AHI ≥5 were RDI MAN 0.88 (95% confidence limits 0.81–0.96), RDI RAW 0.86 (0.76–0.94), ODI MAN 0.86 (0.77–0.95), ODI RAW 0.84 (0.75–0.93) and ODI SOX 0.83 (0.73–0.93). Conclusions: We conclude that the RDI and the ODI, measured at home on the same night, give similar predictions of the laboratory AHI, measured on a different night. The differences between the two methods are small compared with the reported night-to-night variation of the AHI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmjopen-2015-007956

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 49

Metadata

Authors
Dawson, A., Loving, R. T., Gordon, R. M., Abel, S. L., Loewy, D., Kripke, D. F., & Kline, L. E.
Venue
BMJ Open
Publisher
BMJ
Published
2015-06
Volume
5
Issue
6
Pages
e007956
ISSN
2044-6055 (ISSN-L)
OpenAlex
W2263042932
Cited by
49
References
7
FWCI
3.23
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography? https://app.cochat.ai/papers/10.1136/bmjopen-2015-007956
The paper
Dawson, A., Loving, R. T., Gordon, R. M., Abel, S. L., Loewy, D., Kripke, D. F., & Kline, L. E. (2015). Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography? BMJ Open. https://doi.org/10.1136/bmjopen-2015-007956

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.