Diagnostic yield of an ambulatory patch monitor in patients with unexplained syncope after initial evaluation in the emergency department: the PATCH-ED study
The DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Diagnosing underlying arrhythmia in ED syncope patients remains problematic. This study investigates diagnostic yield, event prevalence, patient satisfaction and compliance, and influence on resource utilisation of an ambulatory patch monitor in unexplained ED syncope patients. METHODS: Prospective pilot study conducted in a single tertiary ED in Scotland between 17 November 2015 and 16 June 2017 with a historical unmatched comparator group. Patients 16 years or over presenting within 6 hours of unexplained syncope were fitted in the ED with an ambulatory patch ECG recorder (Zio XT monitor), which continuously records a single-lead ECG for up to 14 days. Patients with an obvious underlying cause were excluded. An unmatched historical group of 603 syncope patients with no obvious diagnosis in ED, recruited to a prior cohort study (2007-2008), were used as a comparator. Primary endpoint was symptomatic significant arrhythmia at 90-day follow-up. RESULTS: During the prospective study period, 86 patients were recruited. 90-day diagnostic yield for symptomatic significant arrhythmia was 10.5% (95% CI 4.0 to 16.9; 9 of 86) versus 2.0% (95% CI 0.9 to 3.1; 12 of 603) in the comparator group. 24 patients (27.9%) had a significant arrhythmia (five serious); 26 patients (30.2%) had serious outcomes (major adverse cardiac event and/or death). Blinded patch report review suggested the patch would significantly reduce requirement for standard outpatient ambulatory ECG monitoring. 56 of 76 returned patches had a diagnostic finding within±45 s of a triggered/diary event (73.7% diagnostic utility; 95% CI 63.7 to 83.6); 34 of 56 (61%) for sinus rhythm or ectopic beats only. CONCLUSIONS: Routine, early ambulatory ECG monitoring in ED patients with unexplained syncope is probably warranted. A large-scale trial comparing this approach to standard care with cost-effectiveness and safety analysis is now required. TRIAL REGISTRATION: NCT02683174.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Third universal definition of myocardial infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Authors/Task Force Members Chairpersons, Thygesen, K., Alpert, J. S., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs184 · Cited by 3,058
Third universal definition of myocardial infarction
the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.122 · Cited by 2,053
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citationBarrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
The ROSE (Risk Stratification of Syncope in the Emergency Department) Study
Reed, M. J., Newby, D. E., Coull, A. J., Prescott, R. J., Jacques, K. G., & Gray, A. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.049 · Cited by 272
Self-citationIncremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
Gibson, T. C., & Heitzman, M. R. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90628-3 · Cited by 229
Cited by
Lampert, R., Chung, E. H., Ackerman, M. J., Arroyo, A. R., Darden, D., Deo, R., Dolan, J., Etheridge, S. P., Gray, B. R., Harmon, K. G., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.05.018 · Cited by 167
Smart Wearables for Cardiac Monitoring—Real-World Use beyond Atrial Fibrillation
Duncker, D., Ding, W. Y., Etheridge, S., Noseworthy, P. A., Veltmann, C., Yao, X., Bunch, T. J., & Gupta, D. (2021) · Sensors · doi:10.3390/s21072539 · Cited by 128
“Similar application in patients with unexplained syncope who presented to the emergency department resulted in a diagnostic yield of 27.9% [12].”
BackgroundInfluentialThe Use of Wearable ECG Devices in the Clinical Setting: A Review
Kamga, P., Mostafa, R., & Zafar, S. (2022) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-022-00248-x · Cited by 94
Bouzid, Z., Al‐Zaiti, S. S., Bond, R., & Sejdić, E. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.02.030 · Cited by 115
Yenikomshian, M. A., Jarvis, J. L., Patton, C., Yee, C. W., Mortimer, R., Birnbaum, H. G., & Topash, M. (2019) · Current Medical Research and Opinion · doi:10.1080/03007995.2019.1610370 · Cited by 71
Impact of Mobile Health Devices for the Detection of Atrial Fibrillation: Systematic Review
Biersteker, T. E., Schalij, M. J., & Treskes, R. W. (2021) · JMIR mhealth and uhealth · doi:10.2196/26161 · Cited by 35
“Barrett et al [18] reported no baseline characteristics, and Holter timing was unclear.”
InfluentialKim, J. Y., Oh, I., Lee, H., Lee, J. H., Cho, Y., Gil, Y., Jung, S., Kim, D. I., Shin, M. G., Yoo, J. Y., et al. (2023) · Journal of Arrhythmia · doi:10.1002/joa3.12865 · Cited by 30
Liang, F., Yang, X., Peng, W. H., Zhen, S., Cao, W., Li, Q., Xiao, Z., Gong, M., Wang, Y., & Gu, D. (2023) · The Lancet Regional Health - Western Pacific · doi:10.1016/j.lanwpc.2023.100817 · Cited by 37
“54 It also can be used in physician diagnostics such as predicting the occurrence of hypertension, 55 as well as deep learning to measure plaque volume and stenosis severity.”
BackgroundApproach to syncope in the emergency department
Reed, M. J. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2018-207767 · Cited by 29
“[46] In this study, a third of the significant and symptomatic significant arrhythmias were captured within the first 24 hours”
BackgroundSelf-citationProbst, M. A., Su, E., Weiss, R. E., Yagapen, A. N., Malveau, S. E., Adler, D. H., Bastani, A., Baugh, C. W., Caterino, J. M., Clark, C. L., et al. (2019) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2019.03.031 · Cited by 26
Dan, G.-A., Scherr, D., Jubele, K., Farkowski, M. M., Iliodromitis, K., Conte, G., Jędrzejczyk-Patej, E., Vitali-Serdoz, L., & Potpara, T. S. (2020) · EP Europace · doi:10.1093/europace/euaa085 · Cited by 20
“Indeed, early ECG monitoring, using ambulatory ECG recording devices, seems to be warranted, especially for patients presenting to the ED with SUO or suggestive of an arrhythmic origin, resulting in reduced hospitalization and wasteful resource use.(19,20) Moreover, a recent systematic review showed that clinical exam…”
BackgroundExternal Cardiac Loop Recorders: Functionalities, Diagnostic Efficacy, Challenges and Opportunities
Rajanna, R. R., Sriraam, N., Prakash, V. S. R., Vittal, P. R., Arun, U., & Sahoo, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3055219 · Cited by 17
Castaño, F. A., Gissel, C., & Hernández, A. M. (2022) · JMIR Medical Informatics · doi:10.2196/40826 · Cited by 18
“The diagnostic yield has been shown to be a major determinant in a technique’s economic assessment; for example, in diagnosis after palpitations [62] or syncopes [63,64], in screening of athletes [65,66], or in identifying asymptomatic atrial fibrillation [33,67].”
Overview of Wearable Healthcare Devices for Clinical Decision Support in the Prehospital Setting
Gathright, R., Mejia, I., Gonzalez, J. M., Torres, S. I. H., Berard, D., & Snider, E. J. (2024) · Sensors · doi:10.3390/s24248204 · Cited by 18
Patel, U. K., Malik, P., Patel, N., Patel, P., Mehta, N. N., Urhoghide, E., Aedma, S. K., Chakinala, R. C., Shah, S., & Arumaithurai, K. (2021) · Cureus · doi:10.7759/cureus.12437 · Cited by 8
“, 2018 (Scotland) [27] 86 Prospective pilot study.”
BackgroundReed, M. J., Grubb, N. R., Lang, C., Goodacre, S. W., O’Brien, R., Weir, C. J., Thokala, P., Freeman, N., Blackstock, C., Dinsmore, L., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-069530 · Cited by 6
Self-citationAccess and reimbursement of ambulatory cardiac monitoring across Europe
Boriani, G., Brachmann, J., Lewalter, T., Wright, D. J., Badertscher, P., Gale, C. P., Merino, J. L., Pürerfellner, H., & Lip, G. Y. H. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf102 · Cited by 6
Biersteker, T. E., Hilt, A. D., van der Velde, E. T., Schalij, M. J., & Treskes, R. W. (2021) · JMIR Cardio · doi:10.2196/26072 · Cited by 6
“Oftentimes, studies only use 1 device, compared with up to 7 devices of the Box or a patch is studied for its diagnostic capabilities of rhythm disturbances [38-40].”
MethodAssessment of a new KoMaWo electrode-patch configuration accuracy and review of the literature
Boszko, M., Osak, G., Żurawska, N., Skoczylas, K., Krzowski, B., Wróblewski, G., Maciejewski, A., Sobiech, J., Ostrowski, S., Grabowski, M., et al. (2022) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2022.07.004 · Cited by 3
Moore, A., Gershon, C. A., Fiske, C., Sun, B., Nazer, B., & Kea, B. (2024) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2023.12.009 · Cited by 2
Pearsons, A., Hanson, C. L., Neubeck, L., Blackstock, C., Clarke, E., & Reed, M. J. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-095927 · Cited by 2
“The 10–12 There is increasing evidence that the majority of arrhythmic outcomes experienced by medium and high-risk patients can be identified within 15 days of the index ED syncope presentation, 13–15 and monitoring should, therefore, be initiated as close to the index visit as possible.”
Self-citationReed, M. J., Brutin, H., Grubb, N. R., Lang, C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018) · Emergency Care Journal · doi:10.4081/ecj.2018.7652 · Cited by 3
“©Copyright M.J. Reed et al., 2018 Licensee PAGEPress, Italy Emergency Care Journal 2018; 14:7652 doi:10.4081/ecj.2018.7652 No n-c om me rci al u on ly [Emergency Care Journal 2018; 14:7652] [page 69] BNP is a natriuretic peptide hormone, released from myocytes in association with increased pressure on the cardiac musc…”
BackgroundInfluentialSelf-citationHigh‐Risk ECG in Syncope: High Risk or Overstated?
Bellicini, M. G., & Reed, M. J. (2026) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.70476 · Cited by 1
Self-citationSmart IoT-Based Cardiac Devices for Ambulatory Healthcare Monitoring
Joy, S. I., Moorthi, M., & Kumar, K. S. (2024) · Lecture notes in networks and systems · doi:10.1007/978-981-97-5146-4_39 · Cited by 1
Managing Syncope/Collapse in the Emergency Department
Reed, M. J. (2020) · Springer eBooks · doi:10.1007/978-3-030-44507-2_12 · Cited by 1
Self-citationYang, S., & ZIMETBAUM, P. J. (2020) · Springer eBooks · doi:10.1007/978-3-030-47868-1_26 · Cited by 1
Evaluating the Process of Ambulatory Electrocardiographic Monitor Application and Completion Rates
Bhatnagar, A. S. (2019) · KU ScholarWorks (The University of Kansas)
Yang, S., & ZIMETBAUM, P. J. (2022) · Springer eBooks · doi:10.1007/978-3-030-88953-1_4
Immediate Ambulatory Electrocardiographic Monitoring in Syncope
Reed, M. J., Goodacre, S. W., Weir, C. J., Dinsmore, L., Nugent, A., Kennel, T., Lang, C., Grubb, N. R., Thokala, P., Kilcoyne, K., et al. (2026) · New England Journal of Medicine · doi:10.1056/nejmoa2605812 · Cited by 1
Self-citation
Metadata
- Authors
- Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J.
- Affiliations
- Edinburgh Royal Infirmary (GB)
- University of Edinburgh (GB)
- Corresponding author
- Reed, Matthew J
- Venue
- Emergency Medicine Journal
- Publisher
- BMJ
- Published
- 2018-06-19
- Volume
- 35
- Issue
- 8
- Pages
- 477-485
- ISSN
- 1351-0622 (ISSN-L)
- 1472-0205
- 1472-0213
- OpenAlex
- W2808746119
- Cited by
- 28
- References
- 28
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 5 · 2020: 3 · 2019: 3 · 2018: 2
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Emergency Medicine Journal (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- NHS Health Scotland
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- unexplained syncope, arrhythmia diagnosis, emergency department, diagnostic yield, major adverse cardiac events, medication adherence, resource utilization (health care)
- MeSH terms
- Aged, Emergency Service, Hospital, Female, Humans, Male, Middle Aged, Patient Compliance, Pilot Projects, Prospective Studies, Scotland, Syncope, Electrocardiography, Ambulatory, Patient Satisfaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.