OBJECTIVE: Prolonged ECG monitoring is standard for atrial fibrillation (AF) screening. This study investigated whether 7-day event triggered (tECG) ECG recording is equivalent to 7-day continuous Holter (cECG) ECG recording for AF screening. DESIGN: Both a cECG (Lifecard CF) and a tECG (R.Test Evolution 3) were simultaneously worn for 7 days by patients with known or suspected paroxysmal AF. RESULTS: In 100 corresponding recordings, median effective duration of monitoring was 165 h (range 10-170 h) for cECG and 137 h (0-169 h) for tECG (p<0.001). Median number and total duration of arrhythmias (AF, atrial flutter or atrial tachycardia) of ≥30 s duration recorded by cECG were 10 (1-428) and 1030 min (≤1-10,020), respectively. An arrhythmia was recorded in 42 cECGs (42%) versus 37 tECGs (37%, p=0.56). Triggered ECG failed to record an arrhythmia in cECG positive cases because of interrupted monitoring in four cases and because of recording failure in one case. Sensitivity, specificity, and positive and negative predictive values of tECG therefore were 88%, 100%, 100%, and 92%, respectively. Quantitative cECG analysis required a median of 20 min (3-205 min) and qualitative tECG analysis 4 min (1-20 min; p<0.001). Skin irritation was a frequent side effect (42%) resulting in premature removal of devices in 16% of patients. CONCLUSION: Sensitivity of tECG for AF screening as compared to cECG is lower, mainly because of shorter effective monitoring duration. Qualitative tECG analysis is less time consuming than quantitative cECG analysis. Skin irritation is a frequent side effect and reason for premature device removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
Self-citationJOSHI, S., CHOI, A. D., KAMATH, G. S., RAISZADEH, F., MARRERO, D., BADHEKA, A., MITTAL, S., & STEINBERG, J. S. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01506.x · Cited by 134
PIORKOWSKI, C., KOTTKAMP, H., TANNER, H., KOBZA, R., NIELSEN, J. C., ARYA, A., & HINDRICKS, G. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00245.x · Cited by 110 · cited 1×
“They allow for prolonged recording of up to 168 h of ECG and are superior to shorter duration Holter ECG, whereas sensitivity is similar compared to daily transtelephonic ECG.(6) 7 Alternatively, event triggered ECG recording systems (tECG) can be employed.”
Self-citation
Cited by
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Wachter, R., Gröschel, K., Gelbrich, G., Hamann, G. F., Kermer, P., Liman, J., Seegers, J., Wasser, K., Schulte, A., Jürries, F., et al. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30002-9 · Cited by 282
Diagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
Charitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
Metadata
- Authors
- Roten, L., Schilling, M., Häberlin, A., Seiler, J., Schwick, N. G., Fuhrer, J., Delacrétaz, E., & Tanner, H.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2012-03-07
- Volume
- 98
- Issue
- 8
- Pages
- 645-649
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2128352423
- Cited by
- 45
- References
- 5
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening? https://app.cochat.ai/papers/10.1136/heartjnl-2011-301455
- The paper
- Roten, L., Schilling, M., Häberlin, A., Seiler, J., Schwick, N. G., Fuhrer, J., Delacrétaz, E., & Tanner, H. (2012). Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening? Heart. https://doi.org/10.1136/heartjnl-2011-301455
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.