CoChat

Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening?

Roten, Laurent, Schilling, Manuel, Häberlin, Andreas, Seiler, Jens, Schwick, Nicola G, Fuhrer, Jürg, Delacrétaz, Etienne, Tanner, Hildegard · 2012 · Heart
Cited by 45

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Prolonged ECG monitoring is standard for atrial fibrillation (AF) screening. This study investigated whether 7-day event triggered (tECG) ECG recording is equivalent to 7-day continuous Holter (cECG) ECG recording for AF screening. DESIGN: Both a cECG (Lifecard CF) and a tECG (R.Test Evolution 3) were simultaneously worn for 7 days by patients with known or suspected paroxysmal AF. RESULTS: In 100 corresponding recordings, median effective duration of monitoring was 165 h (range 10-170 h) for cECG and 137 h (0-169 h) for tECG (p<0.001). Median number and total duration of arrhythmias (AF, atrial flutter or atrial tachycardia) of ≥30 s duration recorded by cECG were 10 (1-428) and 1030 min (≤1-10,020), respectively. An arrhythmia was recorded in 42 cECGs (42%) versus 37 tECGs (37%, p=0.56). Triggered ECG failed to record an arrhythmia in cECG positive cases because of interrupted monitoring in four cases and because of recording failure in one case. Sensitivity, specificity, and positive and negative predictive values of tECG therefore were 88%, 100%, 100%, and 92%, respectively. Quantitative cECG analysis required a median of 20 min (3-205 min) and qualitative tECG analysis 4 min (1-20 min; p<0.001). Skin irritation was a frequent side effect (42%) resulting in premature removal of devices in 16% of patients. CONCLUSION: Sensitivity of tECG for AF screening as compared to cECG is lower, mainly because of shorter effective monitoring duration. Qualitative tECG analysis is less time consuming than quantitative cECG analysis. Skin irritation is a frequent side effect and reason for premature device removal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2011-301455

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 45

Metadata

Authors
Roten, L., Schilling, M., Häberlin, A., Seiler, J., Schwick, N. G., Fuhrer, J., Delacrétaz, E., & Tanner, H.
Venue
Heart
Publisher
BMJ
Published
2012-03-07
Volume
98
Issue
8
Pages
645-649
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2128352423
Cited by
45
References
5
FWCI
4.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening? https://app.cochat.ai/papers/10.1136/heartjnl-2011-301455
The paper
Roten, L., Schilling, M., Häberlin, A., Seiler, J., Schwick, N. G., Fuhrer, J., Delacrétaz, E., & Tanner, H. (2012). Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening? Heart. https://doi.org/10.1136/heartjnl-2011-301455

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.