Cost-effectiveness of radiofrequency catheter ablation for the treatment of atrial fibrillation in the United Kingdom
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective: To assess the cost-effectiveness of radiofrequency catheter ablation (RFCA) compared with anti-arrhythmic drug (AAD) therapy for the treatment of atrial fibrillation (AF) from the perspective of the UK NHS. Design: Bayesian evidence synthesis and decision analytical model. Methods: A systematic review and meta-analysis was conducted and Bayesian statistical methods used to synthesise the effectiveness evidence from randomised control trials. A decision analytical model was developed to assess the costs and consequences associated with the primary outcome of the trials over a lifetime time horizon. Main outcome measure: Costs from a health service perspective and outcomes measured as quality-adjusted life years (QALYs). Results: The incremental cost-effectiveness ratio of RFCA varied between £7763 and £7910 for each additional QALY according to baseline risk of stroke, with a probability of being cost-effective from 0.98 to 0.99 for a cost-effectiveness threshold of £20 000. Results were sensitive to the duration of quality of life benefits from treatment. Conclusions: RFCA is potentially cost-effective for the treatment of paroxysmal AF in patients’ predominantly refractory to AAD therapy provided the quality-of-life benefits from treatment are maintained for more than 5 years. These findings remain subject to limitations in the existing evidence regarding the nature of life benefits and the prognostic importance of restoring normal sinus rhythm conferred using RFCA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 781 · cited 1×
“The annual rate of revision for patients who receive RFCA was estimated from a large controlled study with a median followup of 900 days.(10) The annual reversion rate for patients receiving AADs was estimated from a multicentre trial examining the long-term efficacy of amiodarone in preventing recurrent AF.”
MethodCost of an emerging epidemic: an economic analysis of atrial fibrillation in the UK
Stewart, S., Murphy, N., Walker, A., McGuire, A., & McMurray, J. J. V. (2004) · Heart · doi:10.1136/hrt.2002.008748 · Cited by 590
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Wynn, G. J., Todd, D. M., Webber, M., Bonnett, L., McShane, J., Kirchhof, P., & Gupta, D. (2014) · Europace · doi:10.1093/europace/eut395 · Cited by 254
Self-citationA review of the cost of atrial fibrillation
Wodchis, W. P., Bhatia, R. S., Leblanc, K., Meshkat, N., & Morra, D. (2012) · Value in Health · doi:10.1016/j.jval.2011.09.009 · Cited by 109
What are the costs of atrial fibrillation?
Blomstrom Lundqvist, C., Lip, G. Y. H., & Kirchhof, P. (2011) · Europace · doi:10.1093/europace/eur087 · Cited by 42
Metadata
- Authors
- McKenna, C., Palmer, S., Rodgers, M., Chambers, D., Hawkins, N., Golder, S., Van Hout, S., Pepper, C., Todd, D., & Woolacott, N.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2008-12-18
- Volume
- 95
- Issue
- 7
- Pages
- 542-549
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W1984254801
- Cited by
- 81
- References
- 5
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.