Non-invasive assessment of aortic stenosis by Doppler ultrasound.
Open accessAbstract
The peak pressure drop across the aortic valve in aortic stenosis has been measured by Doppler ultrasound. Maximum velocity in the Doppler signal from the aortic jet was recorded using a maximum frequency estimator. With an angle close to zero between ultrasound beam and maximal velocity in the jet, peak pressure drop can be calculated from the maximal velocity measured; a larger angle will underestimate maximal velocity and pressure drop. In 57 of 63 patients with aortic stenosis, the aortic jet could be reached by the ultrasound beam and, in 37 of these, peak pressure drop by ultrasound was compared with that obtained at catheterisation. In patients less than 50 years of age the aortic jet was easy to find, the measurement was reproducible, and underestimation of the pressure drop obtained at catheterisation was within 25 per cent in 17 of 18 patients. In patients over 50 years Doppler signals from the aortic jet were more difficult to obtain, and pressure drop was significantly underestimated in one-third, but time of maximum velocity in systole could indicate whether moderate or severe aortic stenosis was present.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound.
Hatle, L., Brubakk, A., Tromsdal, A., & Angelsen, B. (1978) · Heart · doi:10.1136/hrt.40.2.131 · Cited by 539
Self-citationAssessing the Severity of Aortic Stenosis by Phonocardiography and External Carotid Pulse Recordings
BONNER, A. J., Sacks, H. N., & Tavel, M. E. (1973) · Circulation · doi:10.1161/01.cir.48.2.247 · Cited by 77
Cited by
Quiñones, M. A., Otto, C. M., Stoddard, M., Waggoner, A., & Zoghbi, W. A. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120202 · Cited by 2,130
The clinical implications of endothelial dysfunction
Widlansky, M. E., Gokce, N., Keaney, J. F., & Vita, J. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00994-x · Cited by 1,749
Yock, P. G., & Popp, R. L. (1984) · Circulation · doi:10.1161/01.cir.70.4.657 · Cited by 1,640
Berger, M., Haimowitz, A., Van Tosh, A., Berdoff, R. L., & Goldberg, E. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80172-8 · Cited by 742
Noninvasive Doppler determination of cardiac output in man. Clinical validation.
Huntsman, L. L., Stewart, D. K., Barnes, S. R., Franklin, S. B., Colocousis, J. S., & Hessel, E. A. (1983) · Circulation · doi:10.1161/01.cir.67.3.593 · Cited by 595
Currie, P. J., Seward, J. B., Reeder, G. S., Vlietstra, R. E., Bresnahan, D. R., Bresnahan, J. F., Smith, H. C., Hagler, D. J., & Tajik, A. J. (1985) · Circulation · doi:10.1161/01.cir.71.6.1162 · Cited by 520
Oh, J. K., Taliercio, C. P., Holmes, D. R., Reeder, G. S., Bailey, K. R., Seward, J. B., & Tajik, A. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90286-0 · Cited by 413
Determination of the stenotic aortic valve area in adults using Doppler echocardiography
Otto, C. M., Pearlman, A. S., Comess, K. A., Reamer, R. P., Janko, C. L., & Huntsman, L. L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80460-0 · Cited by 391
Accurate noninvasive quantification of stenotic aortic valve area by Doppler echocardiography.
Zoghbi, W. A., Farmer, K. L., Soto, J. G., Nelson, J. G., & Quinones, M. A. (1986) · Circulation · doi:10.1161/01.cir.73.3.452 · Cited by 374
American society of echocardiography
Ryan, T., & Khandheria, B. K. (2000) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(00)90052-x · Cited by 347
García-Fernández, M. N., Pérez-David, E., Quiles, J., Peralta, J., García-Rojas, I., Bermejo, J., Moreno, M., & Silva, J. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00954-9 · Cited by 327
Baumgartner, H., Stefenelli, T., Niederberger, J., Schima, H., & Maurer, G. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00066-2 · Cited by 316
Kelly, T. A., Rothbart, R. M., Cooper, C. M., Kaiser, D. L., Smucker, M. L., & Gibson, R. S. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91317-3 · Cited by 313
Nitroprusside in Critically Ill Patients with Left Ventricular Dysfunction and Aortic Stenosis
Khot, U. N., Novaro, G. M., Popović, Z. B., Mills, R. M., Thomas, J. D., Tuzcu, E. M., Hammer, D., Nissen, S. E., & Francis, G. S. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022021 · Cited by 276
Quantification of pressure gradients across stenotic valves by Doppler ultrasound
Stamm, R. B., & Martin, R. P. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80311-8 · Cited by 275
Doppler Echocardiography: Theory, Instrumentation, Technique, and Application
NISHIMURA, R. A., MILLER, F. A., CALLAHAN, M. J., BENASSI, R. C., SEWARD, J. B., & TAJIK, A. J. (1985) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)60540-0 · Cited by 263
Smoking and Obesity Are Associated with the Progression of Aortic Stenosis
Ngo, M. V., Gottdiener, J. S., Fletcher, R. D., Fernicola, D. J., & Gersh, B. J. (2001) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2001.00839.x · Cited by 61
Metadata
- Authors
- Hatle, L., Angelsen, B. A., & Tromsdal, A.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1980-03-01
- Volume
- 43
- Issue
- 3
- Pages
- 284-292
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2168003003
- Cited by
- 527
- References
- 2
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.