Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 694

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Non-invasive measurement of human endothelium dependent arterial responses: accuracy and reproducibility.

Open access
Sorensen, K. E., Celermajer, D. S., Spiegelhalter, D. J., Georgakopoulos, D., Robinson, J., Thomas, O., Deanfield, J. E.·1995·Heart

Abstract

OBJECTIVE: To assess a non-invasive test for endothelial dysfunction, an important early event in the atherogenic process. METHODS: Using high resolution ultrasound, the accuracy of detecting small changes in vessel diameter was assessed using phantom "arteries", and the same equipment was then used to measure flow mediated dilatation in the brachial artery of 40 healthy adults aged 22-51 years, studied on four occasions; intervals between scans were 1-2 days, 1-2 weeks, and 2-4 months. RESULTS: Differences between pairs of phantom "arteries" with diameters 0.1-0.2 mm apart were correctly estimated in 162 of 264 cases (61%); no measurement by any of four independent observers was > 0.1 mm in error, and the mean error was 0.04 mm. For in vivo scans, the overall coefficient of variation for flow mediated dilatation was 1.8% (1.6% for women, 1.9% for men, P = 0.18). In 34/40 subjects (85%), all values for flow mediated dilatation were within 2.5% of the overall mean for each subject. A nested analysis of variance showed the expected between patient variability, and also significant day to day variation, but little between weeks or months. Using these data to generate power function analyses, we calculated that for individuals, an improvement in flow mediated dilatation of 4-8% is significantly greater than natural variability. In clinical trials, a mean improvement in flow mediated dilatation of at least 2% would usually be required to detect a treatment benefit, with much larger subject numbers needed for a parallel group compared to a crossover trial design. CONCLUSIONS: Vascular responses to endothelium dependent and independent stimuli in systemic arteries can be studied non-invasively in man. Subjects should be studied on at least two occasions before and after any intervention, to optimise the chance of showing a significant effect from any potentially beneficial therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.74.3.247

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Sorensen, K. E., Celermajer, D. S., Spiegelhalter, D. J., Georgakopoulos, D., Robinson, J., Thomas, O., & Deanfield, J. E.
Venue
Heart
Publisher
BMJ
Published
1995-09-01
Volume
74
Issue
3
Pages
247-253
ISSN
1355-6037 (ISSN-L)
OpenAlex
W2113446450
Cited by
694
References
1
FWCI
13.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.