Sick building syndrome: Figure 1
Open accessAbstract
The sick building syndrome (SBS) consists of a group of mucosal, skin, and general symptoms that are temporally related to working in particular buildings. It is the workers who are symptomatic, but the building or its services which are the cause. The common symptoms and a method of assessment are shown in box 2. The average number of work related symptoms per occupant is known as the building symptom index. It can be measured reproducibly by simple questionnaire surveys. The building symptom index shows a wide variation between different buildings (fig 1); “sicker” buildings often have conditions of air temperature, humidity, and lighting levels that fully comply with current standards. Some of the reproducible “facts” shown in studies in different countries are shown in box 1, and factors related to higher (sicker) building symptom indices shown in box 3. Box 4 shows the WHO standards for the management of building ventilation systems. Money spent on the building services is likely to be cost effective in terms of the lost productivity in symptomatic workers. Figure 1 Range of building symptom indices in a group of buildings studied with the same questionnaire with a maximum of 10 symptoms (the actual BSI is dependent on the number of possible positive answers and differs between questionnaires). ### Box 1: Reproducible observations related to sick building syndrome (?facts)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
SICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERS
(1987) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/31.4a.493 · Cited by 416
The sick building syndrome: prevalence studies.
Finnegan, M. J., Pickering, C. A., & Burge, P. S. (1984) · BMJ · doi:10.1136/bmj.289.6458.1573 · Cited by 373
Self-citationFanger, P. O. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90051-5 · Cited by 371
Occupational asthma caused by chloramines in indoor swimming-pool air
Thickett, K. M., McCoach, J. S., Gerber, J. M., Sadhra, S., & Burge, P. S. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00232802 · Cited by 266
Self-citationMendell, M. J., & Smith, A. H. (1990) · American Journal of Public Health · doi:10.2105/ajph.80.10.1193 · Cited by 258
The “sick” building syndrome in the office environment: The Danish town hall study
Skov, P., Valbjørn, O., & DISG (1987) · Environment International · doi:10.1016/0160-4120(87)90190-5 · Cited by 233
Skov, P., Valbjorn, O., & Pedersen, B. V. (1989) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1851 · Cited by 228
Jaakkola, J. J. K., Heinonen, O. P., & Seppänen, O. (1989) · Environment International · doi:10.1016/0160-4120(89)90022-6 · Cited by 169
Air pollution sources in offices and assembly halls, quantified by the olf unit
Fanger, P. O., Lauridsen, J., Bluyssen, P., & Clausen, G. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90052-7 · Cited by 168
Health and Indoor Climate Complaints of 7043 office Workers in 61 Buildings in the Netherlands
Zweers, T., Preller, L., Brunekreef, B., & Boleij, J. S. M. (1992) · Indoor Air · doi:10.1111/j.1600-0668.1992.00001.x · Cited by 159
Brasche, S., Bullinger, M., Morfeld, M., GEBHARDT, H. J., & Bischof, W. (2001) · Indoor Air · doi:10.1034/j.1600-0668.2001.110402.x · Cited by 151
Dust and the Sick Building Syndrome
Gyntelberg, F., Suadicani, P., Nielsen, J. W., Skov, P., Valbjørn, O., Nielsen, P., Schneider, T., Jorgensen, O., Wolkoff, P., Wilkins, C. K., et al. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.00003.x · Cited by 133
Work-related illness in offices: A proposed model of the “sick building syndrome”
Hedge, A., Burge, P. S., Robertson, A. S., Wilson, S., & Harris-Bass, J. (1989) · Environment International · doi:10.1016/0160-4120(89)90020-2 · Cited by 125
Self-citationRobertson, A. S., Burge, P. S., Hedge, A., Sims, J., Gill, F. S., Finnegan, M., Pickering, C. A., & Dalton, G. (1985) · BMJ · doi:10.1136/bmj.291.6492.373 · Cited by 108
Self-citationPersistent Asthma After Inhalation of a Mixture of Sodium Hypochlorite and Hydrochloric Acid
Deschamps, D., Soler, P., Rosenberg, N., Baud, F. J., & Gervais, P. (1994) · CHEST Journal · doi:10.1378/chest.105.6.1895 · Cited by 106
Stenberg, B., Eriksson, N., Höög, J., Sundell, J., & Wall, S. (1994) · International Journal of Epidemiology · doi:10.1093/ije/23.6.1190 · Cited by 102
Indoor Particles and Symptoms Among Office Workers: Results from a Double-Blind Cross-Over Study
Mendell, M. J., Fisk, W. J., Petersen, M. R., Hines, C. J., Dong, M., Faulkner, D. M., Deddens, J. A., Ruder, A. M., Sullivan, D. P., & Boeniger, M. F. (2002) · Epidemiology · doi:10.1097/00001648-200205000-00010 · Cited by 102
Mizoue, T. (2001) · American Journal of Epidemiology · doi:10.1093/aje/154.9.803 · Cited by 86
Epidemiology of sick building syndrome and its associated risk factors in Singapore.
Ooi, P. L., Goh, K. T., Phoon, M. H., et al. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.3.188 · Cited by 86
Nordström, K., Norbäck, D., & Akselsson, R. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.3.170 · Cited by 77
Burge, S., & Richardson, M. (1994) · Thorax · doi:10.1136/thx.49.8.842 · Cited by 75
Sundell, J., Lindvall, T., & Stenberg, B. (1994) · Environment International · doi:10.1016/0160-4120(94)90141-4 · Cited by 71
Ventilation rate in office buildings and sick building syndrome.
Jaakkola, J. J. K., & Miettinen, P. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.11.709 · Cited by 68
Effect of a New Ventilation System on Health and Well-Being of Office Workers
Menzies, D., Pasztor, J., Nunes, F., Leduc, J., & Chan, C.-H. (1997) · Archives of Environmental Health An International Journal · doi:10.1080/00039899709602212 · Cited by 57
Sundell, J., Lindvall, T., Stenberg, B., & Wall, S. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00003.x · Cited by 56
Human Perception, of Humidity Under Four Controlled Conditions
Andersen, I., Lundqvist, G. R., & Proctor, D. F. (1973) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1973.10666213 · Cited by 48
Dampness and Respiratory Symptoms among Workers in Daycare Centers in a Subtropical Climate
Li, C.-S., Hsu, C.-W., & Lu, C.-H. (1997) · Archives of Environmental Health An International Journal · doi:10.1080/00039899709603803 · Cited by 41
"Coughing water": bronchial hyperreactivity induced by swimming in a chlorinated pool.
Mustchin, C. P., & Pickering, C. (1979) · Thorax · doi:10.1136/thx.34.5.682 · Cited by 41
Beyond Air Quality—Factors That Affect Prevalence Estimates of Sick Building Syndrome
Mikatavage, M. A., Rose, V. E., Funkhouser, E., et al. (1995) · American Industrial Hygiene Association Journal · doi:10.1080/15428119591016377 · Cited by 10
Cited by
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.128376 · Cited by 562
Healing environment: A review of the impact of physical environmental factors on users
Huisman, E. R. C. M., Morales, E., van Hoof, J., & Kort, H. S. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.06.016 · Cited by 528
De Croon, E., Sluiter, J., Kuijer, P. P., & Frings-Dresen, M. (2005) · Ergonomics · doi:10.1080/00140130512331319409 · Cited by 450
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Metadata
- Authors
- Burge, P. S.
- Venue
- Occupational and Environmental Medicine
- Publisher
- BMJ
- Published
- 2004-01-22
- Volume
- 61
- Issue
- 2
- Pages
- 185-190
- ISSN
- 0007-1072 (ISSN-L)
- 1351-0711
- 1470-7926
- OpenAlex
- W2135988146
- Cited by
- 345
- References
- 31
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.