Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review.
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Atrial fibrillation (AF) affects around 2% of the population and early detection is beneficial, allowing patients to begin potentially life-saving anticoagulant therapies. Blood pressure (BP) monitors may offer an opportunity to screen for AF. Aim: To identify and appraise studies which report the diagnostic accuracy of automated BP monitors used for opportunistic AF detection. Methods: A systematic search was performed of the MEDLINE, MEDLINE In-Process and EMBASE literature databases. Papers were eligible if they described primary studies of the evaluation of a BP device for AF detection, were published in a peer-reviewed journal and reported values for the sensitivity and specificity. Included studies were appraised using the QUADAS-2 tool to assess their risk of bias and applicability to opportunistic AF detection. Values for the sensitivity and specificity of AF detection were extracted from each paper and compared. Results and Conclusions: We identified seven papers evaluating six devices from two manufacturers. Only one study scored low risk in all of the QUADAS-2 domains. All studies reported specificity >85% and 6 reported sensitivity >90%. The studies showed that BP devices with embedded algorithms for detecting arrhythmias show promise as screening tools for AF, comparing favourably with manual pulse palpation. But the studies used different methodologies and many were subject to potential bias. More studies are needed to more precisely define the sensitivity and specificity of opportunistic screening for AF during BP measurement before its clinical utility in the population of interest can be assessed fully.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Studies have shown that 6 devices from 2 manufacturers were reliable with sensitivities and specificities >85% (Kane 2016).”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Kane 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Hobbs, F., Fitzmaurice, D., Mant, J., Murray, E., Jowett, S., Bryan, S., Raftery, J., Davies, M., & Lip, G. (2005) · Health Technology Assessment · doi:10.3310/hta9400 · Cited by 437
Davis, R. C., Hobbs, F. D. R., Kenkre, J. E., Roalfe, A. K., Iles, R., Lip, G. Y. H., & Davies, M. K. (2012) · Europace · doi:10.1093/europace/eus087 · Cited by 180 · cited 1×
“INTRODUCTION Atrial fibrillation (AF) is a common cardiac arrhythmia that affects around 2% of the population and around 8% of those aged over 75 years.(1) The presence of AF can increase a patient’s risk of stroke by up to a factor of five;(2) however, this risk can be significantly reduced through anticoagulation th…”
BackgroundKearley, K., Selwood, M., Van den Bruel, A., Thompson, M., Mant, D., Hobbs, F. R., Fitzmaurice, D., & Heneghan, C. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004565 · Cited by 106
Wiesel, J., Arbesfeld, B., & Schechter, D. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.07.016 · Cited by 80 · cited 2×
“Additionally, our paper highlights the three peer-reviewed studies 15 – 17 published since the Verberk and de Leeuw paper, emphasising that this is an active area of research.”
BackgroundResultWiesel, J., Abraham, S., & Messineo, F. C. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.01.331 · Cited by 58 · cited 4×
“Additionally, our paper highlights the three peer-reviewed studies 15 – 17 published since the Verberk and de Leeuw paper, emphasising that this is an active area of research.”
BackgroundMethodInfluential
Research works printed but not linked: 18
- 10.1161/01.STR.22.8.983 · DOI · Paper page
- 10.1016/j.amjmed.2009.12.013 · DOI · Paper page
- Willits, 2014, WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance, Appl Health Econ Health Policy, 12, 255, 10.1007/s40258-014-0096-7 · DOI · Paper page
- 10.1059/0003-4819-155-8-201110180-00009 · doi:10.1059/0003-4819-155-8-201110180-00009
- 10.1093/biomet/26.4.404 · DOI · Paper page
- 10.1371/journal.pmed.1000097 · DOI · Paper page
- 10.1111/j.1540-8159.2004.00499.x · DOI · Paper page
- 10.1038/jhh.2009.5 · DOI
- 10.1038/ajh.2009.98 · DOI · Paper page
- 10.1007/s12325-011-0087-0 · DOI
- Ermini, 2013, Switching from traditional to automatic sphygmomanometer increases opportunistic detection of atrial fibrillation in hypertensive patients, Br J Med Pract, 6, 616
- 10.1016/j.jstrokecerebrovasdis.2006.07.004 · DOI
- Huang, 2009, Accuracy of automated oscillometric blood pressure monitors in the detection of cardiac arrhythmias, Blood Press Monit, 14, 91, 10.1097/MBP.0b013e32832a40a5 · DOI
- 10.1586/erd.12.46 · DOI
- Taggar JS , Coleman T , Lewis S , et al . Accuracy of methods for detecting an irregular pulse and suspected atrial fibrillation: a systematic review and meta-analysis. Eur J Prev Cardiol 2015. Published Online First: 13 October 2015. doi:10.1177/2047487315611347 · DOI · Paper page
- Verberk, 2016, Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations, Int J Cardiol, 203, 465, 10.1016/j.ijcard.2015.10.182 · DOI · Paper page
- Uittenbogaart, 2015, Detecting and diagnosing atrial fibrillation (D2AF): study protocol for a cluster randomised controlled trial, Trials, 16, 478, 10.1186/s13063-015-1006-5 · DOI
- Cooke, 2006, Is pulse palpation helpful in detecting atrial fibrillation? A systematic review, J Fam Pract, 55, 130
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Metadata
- Authors
- Kane, S. A., Blake, J. R., McArdle, F. J., Langley, P., & Sims, A. J.
- Affiliations
- Newcastle upon Tyne Hospitals NHS Foundation Trust, Royal Victoria Infirmary, Newcastle upon Tyne, UK
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
- ORCID
- Kane, Sarah A
- Venue
- Open Heart
- Publisher
- BMJ
- Published
- 2016-04
- Volume
- 3
- Issue
- 1
- Pages
- e000362
- ISSN
- 2053-3624
- Cited by
- 27
- References
- 6
- Language
- en
- Update notices
- correction (2016-05-05)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review. https://app.cochat.ai/papers/10.1136/openhrt-2015-000362
- The paper
- Kane, S. A., Blake, J. R., McArdle, F. J., Langley, P., & Sims, A. J. (2016). Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review. Open Heart. https://doi.org/10.1136/openhrt-2015-000362
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.