CoChat

Do we need 30 min cortisol measurement in the short synacthen test: a retrospective study

Kumar, Rajeev, Carr, Peter, Moore, Kimberley, Rajput, Zeeshan, Ward, Louise, Wassif, W S · 2020 · Postgraduate Medical Journal

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Objective: The short synacthen test (SST) is widely used across the UK to assess adrenal reserve but there remains no consensus on the timing of cortisol sampling to help diagnose adrenal insufficiency. The main objective of our study was to see if both 30 and 60 min sample are required following administration of synacthen to investigate suspected adrenal insufficiency (AI). Design: This was a single-centre retrospective study of 393 SSTs measuring 0, 30 and 60 min cortisol levels after administration of 250 µg of synacthen. Patients and methods: All the SSTs for patients suspected of primary or secondary AI between April 2016 and October 2018 were included in this study. The tests were performed as per our hospital protocol. A post-adrenocorticotropic hormone (ACTH) cortisol response of 420 nmol/L at any time point was considered adequate to rule out AI. The data were analysed to ascertain the proportion of patients who achieved this level at 30 and/or 60 min. Results: A total of 393 SST results were included in this study. Patients were divided into two groups depending on whether (group A) or not (group B) they were on steroids. Overall, a total of 313 (79.6%) subjects achieved cortisol level of ≥420 nmol/L at 30 and 60 min while 19 (4.8%) had late response (ie, insufficient 30 min cortisol levels, rising to ≥420 nmol/L at 60 min). Another 61 subjects (15.5%) showed insufficient response at both 30 and 60 min (ie, failed to achieved level of ≥420 nmol/L). Importantly, there was no patient in either group who had adequate response at 30 min and then failed at 60 min. Patients in group A were more likely to have inadequate response at both 30 and 60 min while patients in group B were more likely to have normal response at both time points. Conclusions: Our results suggest that about 5% of people undergoing SST may be inappropriately diagnosed as having AI (and subjected to long-term unnecessary steroid treatment) if the 60 min sample is not maintained. We suggest that 30 min sample does not add any additional diagnostic utility and can be omitted thus simplifying SST even further and saving on cost and resources. We propose that single measurement after 60 min of administration of synthetic ACTH is a sufficient screening test for AI.

Overview

Integrity signals

Registry

Crossref · 10.1136/postgradmedj-2019-137125

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Cited by

See all 8

Metadata

Authors
Kumar, R., Carr, P., Moore, K., Rajput, Z., Ward, L., & Wassif, W. S.
Affiliations
  • Bedford Hospital NHS Trust (GB)
  • The Open University (GB)
Corresponding author
Kumar, Rajeev
Venue
Postgraduate Medical Journal
Published
2019-12-06
Volume
96
Issue
1138
Pages
467-472
ISSN
  • 0032-5473 (ISSN-L)
  • 1469-0756
OpenAlex
W2994583092
Cited by
8
References
26
Citations by year
2025: 3 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1
FWCI
0.61
Type
journal article
Language
en
Open access
closed
Locations
  • Postgraduate Medical Journal (publishedVersion)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal Regulation and Hypertension
Keywords
ACTH stimulation test, adrenal insufficiency, Addison's disease, secondary adrenal insufficiency, Synacthen, adrenal reserve, corticosteroid therapy, diagnostic accuracy, test simplification, cost reduction, adrenal function testing, adrenal incidentaloma
MeSH terms
Adrenal Insufficiency, Adult, Aged, Cosyntropin, Diagnostic Tests, Routine, Female, United Kingdom, Humans, Hydrocortisone, Male, Middle Aged, Predictive Value of Tests, Retrospective Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.