Principles of Computerized Tomographic Imaging
The DOI matches its Crossref record.
Abstract
Tomography refers to the cross-sectional imaging of an object from either transmission or reflection data collected by illuminating the object from many different directions. The impact of tomography in diagnostic medicine has been revolutionary, since it has enabled doctors to view internal organs with unprecedented precision and safety to the patient. There are also numerous nonmedical imaging applications which lend themselves to methods of computerized tomography, such as mapping of underground resources...cross-sectional imaging of for nondestructive testing...the determination of the brightness distribution over a celestial sphere...three-dimensional imaging with electron microscopy. Principles of Computerized Tomographic Imaging provides a tutorial overview of topics in tomographic imaging covering mathematical principles and theory...how to apply the theory to problems in medical imaging and other fields...several variations of tomography that are currently being researched.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cited by
Items 801–900 of 1,006
A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals
Loudos, G. K., Nikita, K. S., Giokaris, N. D., Styliaris, E., Archimandritis, S. C., Varvarigou, A. D., Papanicolas, C. N., Majewski, S., Weisenberger, D., Pani, R., et al. (2003) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(03)00025-3 · Cited by 53
Tomotherapy: Optimized planning and delivery of radiation therapy
Mackie, T. R., Holmes, T., Reckwerdt, P. J., et al. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060107 · Cited by 53
Wavelet methods for inverting the Radon transform with noisy data
Lee, N.-Y., & Lucier, B. J. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.892445 · Cited by 55
Fourier-based forward and back-projectors in iterative fan-beam tomographic image reconstruction
O'Connor, Y. Z., & Fessler, J. A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.872139 · Cited by 53
Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Wu, Q., Feng, R., Wei, H., Yu, J., & Zhang, Y. (2023) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2023.3281196 · Cited by 79
Chetih, N., & Messali, Z. (2015) · International Conference on Control, Engineering & Information Technology · doi:10.1109/ceit.2015.7233031 · Cited by 52
Song, J., Hong, Y., Wang, G., et al. (2013) · Applied Physics B · doi:10.1007/s00340-013-5435-0 · Cited by 52
Non-standard bone simulation: interactive numerical analysis by computational steering
Yang, Z., Kollmannsberger, S., Düster, A., Ruess, M., García, E. G., Burgkart, R., & Rank, E. (2011) · Computing and Visualization in Science · doi:10.1007/s00791-012-0175-y · Cited by 51
Sinogram Interpolation Method for Sparse-Angle Tomography
Kalke, M., & Siltanen, S. (2014) · Applied Mathematics · doi:10.4236/am.2014.53043 · Cited by 57
Three-dimensional quantification of capillary networks in healthy and cancerous tissues of two mice
Lang, S. C., Müller, B., Dominietto, M. D., et al. (2012) · Microvascular Research · doi:10.1016/j.mvr.2012.07.002 · Cited by 52
CME reconstruction: Pre-STEREO and STEREO era
Thernisien, A. F. R., Vourlidas, A., & Howard, R. A. (2010) · Journal of Atmospheric and Solar-Terrestrial Physics · doi:10.1016/j.jastp.2010.10.019 · Cited by 52
Renghini, C., Giuliani, A., Mazzoni, S., Brun, F., Larsson, E., Baino, F., & Vitale‐Brovarone, C. (2012) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2012.10.016 · Cited by 54
Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography
Sidky, E. Y., Anastasio, M. A., & Pan, X. (2010) · Optics Express · doi:10.1364/oe.18.010404 · Cited by 49
A Survey on Inverse Problems for Applied Sciences
Yaman, F., Yakhno, V. G., & Potthast, R. (2013) · Mathematical Problems in Engineering · doi:10.1155/2013/976837 · Cited by 66
Press, W. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609228103 · Cited by 52
Pham, T.-A., Soubies, E., Goy, A., Lim, J., Soulez, F., Psaltis, D., & Unser, M. A. (2018) · Optics Express · doi:10.1364/oe.26.002749 · Cited by 60
Doran, S. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/164/1/012020 · Cited by 52
An improved cone‐beam reconstruction algorithm for the circular orbit
Hu, H. (1996) · Scanning · doi:10.1002/sca.4950180807 · Cited by 52
Noise properties of grating-based x-ray phase contrast computed tomography
Köhler, T., Engel, K., & Roessl, E. (2011) · Medical Physics · doi:10.1118/1.3532396 · Cited by 51
A novel X-ray computed tomography method for fast measurement of multiphase flow
Wu, C., Cheng, Y., Ding, Y., et al. (2007) · Chemical Engineering Science · doi:10.1016/j.ces.2007.04.026 · Cited by 51
Awaja, F., Arhatari, B. D., Wiesauer, K., et al. (2009) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2009.06.005 · Cited by 51
Microimaging and tomography with chemical speciation
Rau, C., Somogyi, A., & Simionovici, A. (2003) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(02)01737-8 · Cited by 51
Mao, Y. L., Fahimian, B., Osher, S., & Miao, J. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2039660 · Cited by 54
Haberthür, D., Hintermüller, C., Marone, F., et al. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049510019618 · Cited by 51
Alkali-activated calcined smectite clay blended with waste calcium carbonate as a low-carbon binder
Valentini, L., Contessi, S., Dalconi, M. C., Zorzi, F., & Garbin, E. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.02.249 · Cited by 55
In-situ pore size investigations of loaded porous concrete with non-destructive methods
Rifai, H., Staude, A., Meinel, D., et al. (2018) · Cement and Concrete Research · doi:10.1016/j.cemconres.2018.06.008 · Cited by 51
Potentially large post-1505 AD earthquakes in western Nepal revealed by a lake sediment record
Ghazoui, Z., Bertrand, S., Vanneste, K., Yokoyama, Y., Nomade, J., Gajurel, A. P., & van der Beek, P. (2019) · Nature Communications · doi:10.1038/s41467-019-10093-4 · Cited by 55
Characterization of metals in four dimensions
Shahani, A. J., Xiao, X., Lauridsen, E. M., & Voorhees, P. W. (2020) · Materials Research Letters · doi:10.1080/21663831.2020.1809544 · Cited by 50
Application of FEA to image-based models of electrical trees with uniform conductivity
Rowland, S., Schurch, R., Pattouras, M., & Li, Q. (2015) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2015.004922 · Cited by 67
Detection of linear objects in GPR data
Dell’Acqua, A., Sarti, A., Tubaro, S., et al. (2004) · Signal Processing · doi:10.1016/j.sigpro.2003.12.010 · Cited by 51
Radar tomography for NDT: comparison of techniques
Valle, S., Zanzi, L., & Rocca, F. (1999) · Journal of Applied Geophysics · doi:10.1016/s0926-9851(98)00046-9 · Cited by 51
Porosity measurements of sedimentary rocks by means of microfocus X-ray computed tomography (μCT)
Geet, M. V., Lagrou, D., & Swennen, R. (2003) · Geological Society London Special Publications · doi:10.1144/gsl.sp.2003.215.01.05 · Cited by 51
BASIC PRINCIPLES OF ACOUSTIC EMISSION TOMOGRAPHY
Schubert, F. M. (2004) · Cited by 51
Babout, L., Grudzień, K., Wiącek, J., et al. (2018) · Granular Matter · doi:10.1007/s10035-018-0809-y · Cited by 50
Holographic tomographic volumetric additive manufacturing
Álvarez-Castaño, M. I., Madsen, A. E. G., Madrid-Wolff, J. A., Sgarminato, V., Boniface, A., Glückstad, J., & Moser, C. (2025) · Nature Communications · doi:10.1038/s41467-025-56852-4 · Cited by 82
An Iterative CT Reconstruction Algorithm for Fast Fluid Flow Imaging
Eyndhoven, G. V., Batenburg, K. J., Kazantsev, D., Nieuwenhove, V. V., Lee, P. D., Dobson, K. J., & Sijbers, J. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2466113 · Cited by 60
Bian, Z., Ma, J., Huang, J., Zhang, H., Niu, S., Feng, Q., Liang, Z., & Chen, W. (2013) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2013.05.004 · Cited by 51
Tatone, B. S. A., & Grasselli, G. (2014) · Acta Geotechnica · doi:10.1007/s11440-014-0320-5 · Cited by 50
Three‐dimensional analytical magnetic resonance imaging phantom in the Fourier domain
Koay, C. G., Sarlls, J. E., & Özarslan, E. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21292 · Cited by 53
Derluyn, H., Dewanckele, J., Boone, M., Cnudde, V., Derome, D., & Carmeliet, J. (2014) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2013.08.065 · Cited by 56
Chen, D., Goris, B., Bleichrodt, F., et al. (2014) · Ultramicroscopy · doi:10.1016/j.ultramic.2014.08.005 · Cited by 50
In Situ Microtomographic Monitoring of Discharging Processes in Alkaline Cells
Haibel, A., Manke, I., Melzer, A., et al. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3294566 · Cited by 50
Rohde, A., Veidt, M., Rose, L. R. F., et al. (2007) · Ultrasonics · doi:10.1016/j.ultras.2007.09.002 · Cited by 50
Origins of decoherence in coherent X-ray diffraction experiments
Vartanyants, I. A., & Robinson, I. (2003) · Optics Communications · doi:10.1016/s0030-4018(03)01558-x · Cited by 50
Jovanović, I., Sbaiz, L., & Vetterli, M. (2009) · Journal of Atmospheric and Oceanic Technology · doi:10.1175/2009jtecha1266.1 · Cited by 62
Hydrogen partitioning behavior and related hydrogen embrittlement in Al-Zn-Mg alloys
Shimizu, K., Toda, H., Fujihara, H., et al. (2019) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2019.106503 · Cited by 50
3D pore structure analysis of intact ‘Braeburn’ apples using X-ray micro-CT
Janssen, S., Verboven, P., Nugraha, B., et al. (2019) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2019.111014 · Cited by 50
High-resolution three-dimensional mapping of individual grains in polycrystals by topotomography
Ludwig, W., Lauridsen, E. M., Schmidt, S., et al. (2007) · Journal of Applied Crystallography · doi:10.1107/s002188980703035x · Cited by 50
Hybrid diffraction tomography without phase information
Gbur, G., & Wolf, E. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002194 · Cited by 50
Half‐scan cone‐beam X‐ray microtomography formula
Wang, G., Liu, Y., Lin, T. H., et al. (1994) · Scanning · doi:10.1002/sca.4950160406 · Cited by 50
Dastgerdi, J. N., Anbarlooie, B., Miettinen, A., et al. (2018) · Composites Part B Engineering · doi:10.1016/j.compositesb.2018.07.027 · Cited by 49
Alignment of Cryo-Electron Tomography Datasets
Amat, F., Castaño‐Díez, D., Lawrence, A. F., et al. (2010) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(10)82014-2 · Cited by 49
Photoacoustic microtomography using optical interferometric detection
Nuster, R., Holotta, M., Kremser, C., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3333547 · Cited by 49
Heidari, H., den Broek, W. V., & Bals, S. (2011) · Ultramicroscopy · doi:10.1016/j.ultramic.2011.01.021 · Cited by 49
Aronova, M. A., Kim, Y. C., Harmon, R., et al. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.06.008 · Cited by 49
Baddour, N. (2010) · Journal of the Optical Society of America A · doi:10.1364/josaa.27.002144 · Cited by 49
Snapshot 2D tomography via coded aperture x-ray scatter imaging
MacCabe, K. P., Holmgren, A. D., Tornai, M. P., et al. (2013) · Applied Optics · doi:10.1364/ao.52.004582 · Cited by 49
Çetin, M., Karl, W. C., & Willsky, A. S. (2006) · Optical Engineering · doi:10.1117/1.2150368 · Cited by 49
Li, X., & Luo, S. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-73 · Cited by 59
Evidence for a physically bound third component in HD 150136
Mahy, L., Gosset, E., Sana, H., et al. (2012) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201118199 · Cited by 49
Image formation in holographic tomography: high-aperture imaging conditions
Kou, S. S., & Sheppard, C. J. R. (2009) · Applied Optics · doi:10.1364/ao.48.00h168 · Cited by 49
Image Formation in Wide-Field Microscopes Based on Leakage of Surface Plasmon-Coupled Fluorescence
Frisbie, S., Chesnutt, C., Holtz, M. E., et al. (2009) · IEEE photonics journal · doi:10.1109/jphot.2009.2028307 · Cited by 49
Deschler-Erb, E., Lehmann, E. H., Pernet, L., et al. (2004) · Archaeometry · doi:10.1111/j.1475-4754.2004.00180.x · Cited by 49
Object separation in x-ray image sets
Heitz, G., & Chechik, G. (2010) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2010.5539887 · Cited by 51
Coded aperture optimization in compressive X-ray tomography: a gradient descent approach
Cuadros, A. P., & Arce, G. R. (2017) · Optics Express · doi:10.1364/oe.25.023833 · Cited by 53
Block Coordinate Regularization by Denoising
Sun, Y., Liu, J., & Kamilov, U. S. (2020) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2020.2996385 · Cited by 83
Imaging three-dimensional magnetic systems with x-rays
Donnelly, C., & Scagnoli, V. (2020) · Journal of Physics Condensed Matter · doi:10.1088/1361-648x/ab5e3c · Cited by 55
Validation of in vivo fluorochrome concentrations measured using fluorescence molecular tomography
Graves, E. E., Yessayan, D., Turner, G. M., et al. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1993427 · Cited by 49
Incremental algorithm-a new fast backprojection scheme for parallel beam geometries
Cho, Z. H., Chen, C., & Lee, S. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.56333 · Cited by 49
The history and principles of optical computed tomography for scanning 3-D radiation dosimeters
Doran, S., & Krstajić, N. (2006) · Journal of Physics Conference Series · doi:10.1088/1742-6596/56/1/005 · Cited by 49
Coindreau, O., & Vignoles, G. L. (2005) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2005.0311 · Cited by 49
The precision of humidity in GNSS tomography
Rohm, W. (2012) · Atmospheric Research · doi:10.1016/j.atmosres.2011.12.008 · Cited by 48
Displacement in sand under triaxial compression by tracking soil particles on X-ray CT data
Watanabe, Y., Lenoir, N., Otani, J., et al. (2012) · SOILS AND FOUNDATIONS · doi:10.1016/j.sandf.2012.02.008 · Cited by 48
Boden, S., Bieberle, M., & Hampel, U. (2007) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.08.014 · Cited by 48
Radiation dose reduction in medical x‐ray CT via Fourier‐based iterative reconstruction
Fahimian, B., Zhao, Y., Huang, Z., Fung, R., Mao, Y. L., Zhu, C., Khatonabadi, M., DeMarco, J. J., Osher, S., McNitt‐Gray, M. F., et al. (2013) · Medical Physics · doi:10.1118/1.4791644 · Cited by 52
Hagen, C. K., Diémoz, P. C., Endrizzi, M., Rigon, L., Dreossi, D., Arfelli, F., Lopez, F. C., Longo, R., & Olivo, A. (2014) · Optics Express · doi:10.1364/oe.22.007989 · Cited by 48
Hyperspectral image reconstruction for x-ray fluorescence tomography
Gürsoy, D., Biçer, T., Lanzirotti, A., Newville, M. G., & Carlo, F. D. (2015) · Optics Express · doi:10.1364/oe.23.009014 · Cited by 49
Subramanian, S., Koscielniak, J. W., Devasahayam, N., et al. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.01.023 · Cited by 48
Zoubi, A. B., Kim, S., Adams, D. O., & Mathews, V. J. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2903006 · Cited by 46
Preparation of γ-Al2O3/α-Al2O3 ceramic foams as catalyst carriers via the replica technique
Shumilov, V., Kirilin, A., Tokarev, A. V., et al. (2020) · Catalysis Today · doi:10.1016/j.cattod.2020.09.019 · Cited by 48
Hampel, U., Hristov, H. V., Bieberle, A., et al. (2007) · Flow Measurement and Instrumentation · doi:10.1016/j.flowmeasinst.2007.06.001 · Cited by 48
The weighted-distance scheme: a globally optimizing projection ordering method for ART
Mueller, K. D., Yagel, R., & Cornhill, J. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563668 · Cited by 48
Theoretical comparison of Fourier and wavelet encoding in magnetic resonance imaging
Panych, L. P. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491416 · Cited by 48
A curve evolution approach to object-based tomographic reconstruction
Feng, H., Karl, W. C., & Castañón, D. A. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2002.806253 · Cited by 48
A review of methods for automated recognition of casting defects
Mery, D., de Jaeger, T., & Fil'bert, D. V. (2002) · Insight - Non-Destructive Testing and Condition Monitoring · Cited by 48
Sumpf, T. J., Petrovic, A., Uecker, M., et al. (2014) · Cited by 48
Chen, G., Maes, T., Vandervoort, F., et al. (2012) · Rock Mechanics and Rock Engineering · doi:10.1007/s00603-012-0334-y · Cited by 47
Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography
Fahimian, B., Mao, Y. L., Cloetens, P., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/18/008 · Cited by 47
The contribution of synchrotron X-ray computed microtomography to understanding volcanic processes
Polacci, M., Mancini, L., & Baker, D. R. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049509048225 · Cited by 47
Inverse problems in biomedical imaging: modeling and methods of solution
Bertero, M., & Piana, M. (2007) · Springer eBooks · doi:10.1007/88-470-0396-2_1 · Cited by 68
Jung, S., Kim, J.-S., Kim, J., et al. (2009) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2009.02.057 · Cited by 47
Kashiwagi, T., Nakade, K., Saiwai, Y., Minami, H., Kitamura, T., Watanabe, C., Ishida, K., Sekimoto, S., Asanuma, K., Yasui, T., et al. (2014) · Applied Physics Letters · doi:10.1063/1.4866898 · Cited by 47
Stalder, A. K., Ilgenstein, B., Chicherova, N., Deyhle, H., Beckmann, F., Müller, B., & Hieber, S. E. (2014) · International Journal of Materials Research (formerly Zeitschrift fuer Metallkunde) · doi:10.3139/146.111050 · Cited by 47
Integrated Optical Coherence Tomography (OCT) and Fluorescence Laminar Optical Tomography (FLOT)
Chen, Y., Yuan, S., Wierwille, J., Naphas, R., Li, Q., Blackwell, T. R., Winnard, P. T., Raman, V., & Glunde, K. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2037723 · Cited by 51
Lifton, J. J., Malcolm, A. A., & McBride, J. W. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/27/1/015007 · Cited by 47
Palenstijn, W. J., Batenburg, K. J., & Sijbers, J. (2013) · Data Archiving and Networked Services (DANS) · Cited by 56
Voltolini, M., & Ajo-Franklin, J. B. (2020) · Frontiers in Earth Science · doi:10.3389/feart.2020.00207 · Cited by 47
Antil, H., Zichao, W. D., & Khatri, R. (2020) · Calhoun: The Naval Postgraduate School Institutional Archive (Naval Postgraduate School) · Cited by 47
Hatamikia, S., Biguri, A., Herl, G., Kronreif, G., Reynolds, T., Kettenbach, J., Russ, T., Tersol, A., Maier, A., Figl, M., et al. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac8590 · Cited by 65
The Restricted Isometry Property of Subsampled Fourier Matrices
Haviv, I., & Regev, O. (2017) · Lecture notes in mathematics · doi:10.1007/978-3-319-45282-1_11 · Cited by 122
Metadata
- Authors
- Kak, A. C., & Slaney, M.
- Affiliations
- Purdue University West Lafayette (US)
- ORCID
- Slaney, Malcolm
- Venue
- Society for Industrial and Applied Mathematics eBooks
- Published
- 2001-01-01
- OpenAlex
- W2037521346
- Cited by
- 5,809
- References
- 0
- Citations by year
- 2026: 83 · 2025: 106 · 2024: 111 · 2023: 132 · 2022: 112 · 2021: 204 · 2020: 203 · 2019: 216 · 2018: 221 · 2017: 224 · 2016: 252 · 2015: 289 · 2014: 277 · 2013: 286 · 2012: 282
- FWCI
- 38.59
- Type
- book
- Language
- en
- Open access
- closed
- Locations
- Society for Industrial and Applied Mathematics eBooks (publishedVersion)
- Topics
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microwave Imaging and Scattering Analysis
- Keywords
- computed tomography, tomography, cross-sectional imaging, transmission tomography, reflection tomography, diagnostic imaging, non-destructive testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.