Principles of Computerized Tomographic Imaging
The DOI matches its Crossref record.
Abstract
Tomography refers to the cross-sectional imaging of an object from either transmission or reflection data collected by illuminating the object from many different directions. The impact of tomography in diagnostic medicine has been revolutionary, since it has enabled doctors to view internal organs with unprecedented precision and safety to the patient. There are also numerous nonmedical imaging applications which lend themselves to methods of computerized tomography, such as mapping of underground resources...cross-sectional imaging of for nondestructive testing...the determination of the brightness distribution over a celestial sphere...three-dimensional imaging with electron microscopy. Principles of Computerized Tomographic Imaging provides a tutorial overview of topics in tomographic imaging covering mathematical principles and theory...how to apply the theory to problems in medical imaging and other fields...several variations of tomography that are currently being researched.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cited by
Items 301–400 of 1,006
Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT
Cachovan, M., Vija, A., Hornegger, J., & Kuwert, T. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-45 · Cited by 106
Chapter 7: Tomography Diagnostics: Bolometry and Soft-X-Ray Detection
Ingesson, L. C., Alper, B., Peterson, B. J., et al. (2008) · Fusion Science & Technology · doi:10.13182/fst53-528 · Cited by 122
Three-dimensional tomographic reconstruction of ultrashort free electron wave packets
Wollenhaupt, M., Krug, M., Köhler, J., et al. (2009) · Applied Physics B · doi:10.1007/s00340-009-3513-0 · Cited by 122
CONRAD—A software framework for cone‐beam imaging in radiology
Maier, A., Hofmann, H. G., Berger, M., Fischer, P., Schwemmer, C., Wu, H., Mueller, K., Hornegger, J., Choi, J., Rieß, C., et al. (2013) · Medical Physics · doi:10.1118/1.4824926 · Cited by 130
Comparison of medical and industrial X-ray computed tomography for non-destructive testing
du Plessis, A., le Roux, S. G., & Guelpa, A. (2016) · Case Studies in Nondestructive Testing and Evaluation · doi:10.1016/j.csndt.2016.07.001 · Cited by 121
In situ assessment of structural timber using stress-wave measurements
Dackermann, U., Crews, K. I., Kasal, B., Li, J., Riggio, M., Rinn, F., & Tannert, T. (2013) · Materials and Structures · doi:10.1617/s11527-013-0095-4 · Cited by 121
Comparing different ultrasound imaging methods for breast cancer detection
Ozmen, N., Dapp, R., Zapf, M., et al. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006707 · Cited by 120
Soft-tissue phase-contrast tomography with an x-ray tube source
Bech, M., Jensen, T. H., Feidenhans’l, R., Bunk, O., Dávid, C., & Pfeiffer, F. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/010 · Cited by 128
Enhancement and Proof of Accuracy of Industrial Computed Tomography (CT) Measurements
Bartscher, M., Hilpert, U., Goebbels, J., et al. (2007) · CIRP Annals · doi:10.1016/j.cirp.2007.05.118 · Cited by 120
Chon, C. H., Paik, S., Tipton, J. B., et al. (2006) · Langmuir · doi:10.1021/la061661y · Cited by 120
Wang, S., Ferguson, B., Abbott, D., & Zhang, X.-C. (2003) · Journal of Biological Physics · doi:10.1023/a:1024457212578 · Cited by 119
On the implementation of computed laminography using synchrotron radiation
Helfen, L., Myagotin, A., Mikulík, P., Pernot, P., Voropaev, A., Elyyan, M., Michiel, M. D., Baruchel, J., & Baumbach, T. (2011) · Review of Scientific Instruments · doi:10.1063/1.3596566 · Cited by 132
Single-shot tomographic movies of evolving light-velocity objects
Li, Z., Zgadzaj, R., Wang, X., Chang, Y.-Y., & Downer, M. C. (2014) · Nature Communications · doi:10.1038/ncomms4085 · Cited by 121
Computational methods for electron tomography
Fernández, J. (2012) · Micron · doi:10.1016/j.micron.2012.05.003 · Cited by 128
Kaatze, U. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012005 · Cited by 133
Bertrand, L., Bernard, S., Marone, F., Thoury, M., Reiche, I., Gourrier, A., Sciau, P., & Bergmann, U. (2016) · Topics in Current Chemistry · doi:10.1007/s41061-015-0003-1 · Cited by 122
Habaza, M., Kirschbaum, M., Guernth-Marschner, C. R., et al. (2016) · Advanced Science · doi:10.1002/advs.201600205 · Cited by 119
CT dose reduction factors in the thousands using X-ray phase contrast
Kitchen, M. J., Buckley, G. A., Gureyev, T. E., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-16264-x · Cited by 119
Fast Tomographic Reconstruction From Limited Data Using Artificial Neural Networks
Pelt, D. M., & Batenburg, K. J. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2283142 · Cited by 119
Sensitivity of Photon-Counting Based ${\rm K}$-Edge Imaging in X-ray Computed Tomography
Roessl, E., Brendel, B., Engel, K.-J., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2142188 · Cited by 118
Basu, S., Thirumalaiselvi, A., Sasmal, S., et al. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106472 · Cited by 118
Estimation of rainfall fields using commercial microwave communication networks of variable density
Zinevich, A., Alpert, P., & Messer, H. (2008) · Advances in Water Resources · doi:10.1016/j.advwatres.2008.03.003 · Cited by 133
Volumetric tomography of fluorescent proteins through small animals in vivo
Zacharakis, G., Kambara, H., Shih, H., Ripoll, J., Grimm, J., Saeki, Y., Weissleder, R., & Ntziachristos, V. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504628102 · Cited by 118
Simulation of liquid penetration in paper
Hyväluoma, J., Raiskinmäki, P., Jäsberg, A., Koponen, A., Kataja, M., & TIMONEN, J. (2006) · Physical Review E · doi:10.1103/physreve.73.036705 · Cited by 117
GENFIRE: A generalized Fourier iterative reconstruction algorithm for high-resolution 3D imaging
Pryor, A., Yang, Y., Rana, A., Gallagher-Jones, M., Zhou, J., Lo, Y. H., Melinte, G. A., Chiu, W., Rodríguez, J. A., & Miao, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-09847-1 · Cited by 125
Implementation of an optimal first-order method for strongly convex total variation regularization
Jensen, T. L., Jørgensen, J. S., Hansen, P. C., & Jensen, S. H. (2011) · BIT Numerical Mathematics · doi:10.1007/s10543-011-0359-8 · Cited by 127
Characterizing the nano and micro structure of concrete to improve its durability
Monteiro, P. J. M., Kirchheim, A. P., Chae, S. R., et al. (2008) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2008.12.007 · Cited by 116
Projection reconstruction MR imaging using FOCUSS
Ye, J. C., Tak, S., Han, Y., & Park, H. W. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21202 · Cited by 126
Rolland, H., Saintier, N., & Robert, G. (2016) · Composites Part B Engineering · doi:10.1016/j.compositesb.2015.12.021 · Cited by 116
Laser-wakefield accelerators as hard x-ray sources for 3D medical imaging of human bone
Cole, J. M., Wood, J. C., Lopes, N., Põder, K., Abel, R. L., Alatabi, S., Bryant, J., Jin, A., Kneip, S., Mecseki, K., et al. (2015) · Scientific Reports · doi:10.1038/srep13244 · Cited by 121
‘Go with the flow ’: A review of methods and advancements in blood flow imaging
Daly, S. M., & Leahy, M. J. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200071 · Cited by 115
Mapping the local nanostructure inside a specimen by tomographic small-angle x-ray scattering
Schroer, C. G., Kuhlmann, M., Roth, S. V., et al. (2006) · Applied Physics Letters · doi:10.1063/1.2196062 · Cited by 115
A Light Transport Framework for Lenslet Light Field Cameras
Liang, C., & Ramamoorthi, R. (2015) · ACM Transactions on Graphics · doi:10.1145/2665075 · Cited by 117
Millimeter-wave compressive holography
Fernandez-Cull, C., Wikner, D. A., Mait, J. N., Mattheiss, M., & Brady, D. J. (2010) · Applied Optics · doi:10.1364/ao.49.000e67 · Cited by 118
A Review of Deep Learning CT Reconstruction: Concepts, Limitations, and Promise in Clinical Practice
Szczykutowicz, T. P., Toia, G. V., Dhanantwari, A. C., & Nett, B. E. (2022) · Current Radiology Reports · doi:10.1007/s40134-022-00399-5 · Cited by 126
Polarization fields: dynamic light field display using multi-layer LCDs
Lanman, D. R., Wetzstein, G., Hirsch, M., Heidrich, W., & Raskar, R. (2011) · ACM SIGGRAPH Conference and Exhibition on Computer Graphics and Interactive Techniques in Asia (SIGGRAPH Asia) · doi:10.1145/2024156.2024220 · Cited by 116
Detection system for microimaging with neutrons
Williams, S., Hilger, A., Kardjilov, N., et al. (2012) · Journal of Instrumentation · doi:10.1088/1748-0221/7/02/p02014 · Cited by 113
Lose the Views: Limited Angle CT Reconstruction via Implicit Sinogram Completion
Anirudh, R., Kim, H.-J., Thiagarajan, J. J., Mohan, K. A., Champley, K., & Bremer, P. (2018) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2018.00664 · Cited by 152
Regularization in Image Restoration and Reconstruction
Karl, W. C. (2005) · Elsevier eBooks · doi:10.1016/b978-012119792-6/50075-9 · Cited by 127
Image covariance and lesion detectability in direct fan-beam x-ray computed tomography
Wunderlich, A., & Noo, F. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/10/002 · Cited by 113
Peth, S., Nellesen, J., Fischer, G., & Horn, R. (2010) · Soil and Tillage Research · doi:10.1016/j.still.2010.02.007 · Cited by 129
Cone beam optical computed tomography for gel dosimetry I: scanner characterization
Olding, T., Holmes, O., & Schreiner, L. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/10/003 · Cited by 112
Acoustic tomographic imaging of temperature and flow fields in air
Barth, M., & Raabe, A. (2011) · Measurement Science and Technology · doi:10.1088/0957-0233/22/3/035102 · Cited by 112
Geng, G., Myers, R. J., Yu, Y., Shapiro, D. A., Winarski, R. P., Levitz, P., Kilcoyne, A. L. D., & Monteiro, P. J. M. (2018) · Cement and Concrete Research · doi:10.1016/j.cemconres.2018.06.002 · Cited by 113
Ultra fast electron beam X-ray computed tomography for two-phase flow measurement
Fischer, F., & Hampel, U. (2010) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2009.11.016 · Cited by 112
Sung, Y., Choi, W., Lue, N., Dasari, R. R., & Yaqoob, Z. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049502 · Cited by 120
Hampel, U., Bieberle, A., Hoppe, D., et al. (2007) · Review of Scientific Instruments · doi:10.1063/1.2795648 · Cited by 111
Proceedings of 20th International Congress on Acoustics, ICA 2010
Hammershøi, D., Ordoñez, R., Torrente, M., et al. (2010) · Cited by 111
Noise and resolution in images reconstructed with FBP and OSC algorithms for CT
Ziegler, A., Köhler, T., & Proksa, R. (2007) · Medical Physics · doi:10.1118/1.2409481 · Cited by 110
Polarization fields: dynamic light field display using multi-layer LCDs
Lanman, D. R., Wetzstein, G., Hirsch, M., Heidrich, W., & Raskar, R. (2011) · ACM Transactions on Graphics · doi:10.1145/2070781.2024220 · Cited by 126
Byrne, C. L. (2007) · A K Peters/CRC Press eBooks · doi:10.1201/9780429295492 · Cited by 174
Visualization of soil arching on reinforced embankment with rigid pile foundation using X-ray CT
Eskişar, T., Otani, J., & HIRONAKA, J. (2012) · Geotextiles and Geomembranes · doi:10.1016/j.geotexmem.2011.12.002 · Cited by 110
Limitations of ionospheric imaging by tomography
Yeh, K. C., & Raymund, T. D. (1991) · Radio Science · doi:10.1029/91rs01873 · Cited by 110
Tumor delineation using PET in head and neck cancers: Threshold contouring and lesion volumes
Ford, E. C., Kinahan, P. E., Hanlon, L., Alessio, A. M., Rajendran, J. G., Schwartz, D. L., & Phillips, M. H. (2006) · Medical Physics · doi:10.1118/1.2361076 · Cited by 110
Walton, L. A., Bradley, R. S., Withers, P. J., Newton, V. L., Watson, R. E. B., Austin, C., & Sherratt, M. J. (2015) · Scientific Reports · doi:10.1038/srep10074 · Cited by 111
Hintermüller, M., & Wu, T. (2013) · SIAM Journal on Imaging Sciences · doi:10.1137/110854746 · Cited by 111
Markovian reconstruction using a GNC approach
Nikolova, M. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.784433 · Cited by 113
Effect of Porosity on the Stiffness of Cast Steel
Hardin, R. A., & Beckermann, C. (2007) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-007-9390-4 · Cited by 109
Two applications of wavelet transforms in magnetic resonance imaging
Healy, D. M., & Weaver, J. B. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119740 · Cited by 113
Iterative Tomographic Image Reconstruction Using Fourier-Based Forward and Back-Projectors
Matej, S., Fessler, J. A., & Kazantsev, I. G. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.824233 · Cited by 109
NDE application of ultrasonic tomography to a full-scale concrete structure
Choi, H., & Popovics, J. S. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006962 · Cited by 108
Reconstruction in diffraction ultrasound tomography using nonuniform FFT
Bronstein, M. M., Bronstein, A. M., Zibulevsky, M., & Azhari, H. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806423 · Cited by 107
An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms
Panetta, D., Belcari, N., Guerra, A. D., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/14/009 · Cited by 108
Three-dimensional imaging of earth and planetary materials
Carlson, W. D. (2006) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2006.06.020 · Cited by 109
Zhuang, T., Leng, S., Nett, B. E., et al. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/24/007 · Cited by 108
Performance evaluation of image processing algorithms on the GPU
Castaño‐Díez, D., Moser, D., Schönegger, A., Pruggnaller, S., & Frangakis, A. S. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.07.006 · Cited by 123
An Augmented Lagrangian Method for Complex-Valued Compressed SAR Imaging
Güven, H. E., Güngör, A., & Çetin, M. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2580498 · Cited by 114
Sub‐Fresnel‐scale vertical resolution in atmospheric profiles from radio occultation
Karayel, E. T., & Hinson, D. P. (1997) · Radio Science · doi:10.1029/96rs03212 · Cited by 107
DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction
Liu, J., Anirudh, R., Thiagarajan, J. J., He, S., Mohan, K. A., Kamilov, U. S., & Kim, H. (2023) · 2023 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.00963 · Cited by 106
Sub-micron resolution CT for failure analysis and process development
Feser, M., Gelb, J., Chang, H., et al. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/9/094001 · Cited by 106
The micro-imaging station of the TopoTomo beamline at the ANKA synchrotron light source
Rack, A., Weitkamp, T., Trabelsi, S. B., et al. (2009) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2009.04.002 · Cited by 106
Shape and size of microfine aggregates: X-ray microcomputed tomography vs. laser diffraction
Erdoğan, S. T., Garboczi, E. J., & Fowler, D. W. (2007) · Powder Technology · doi:10.1016/j.powtec.2007.02.016 · Cited by 106
Modified iterative Landweber method in electrical capacitance tomography
Jang, J., Lee, S. H., Kim, K. Y., et al. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/7/032 · Cited by 106
Gaudette, R. J., Brooks, D. H., DiMarzio, C. A., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/4/318 · Cited by 106
Streaking artifacts reduction in four‐dimensional cone‐beam computed tomography
Leng, S., Zambelli, J. N., Tolakanahalli, R., et al. (2008) · Medical Physics · doi:10.1118/1.2977736 · Cited by 105
Sanabria, S. J., Özkan, E., Rominger, M. B., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aae2fb · Cited by 105
Guvenilir, A., Breunig, T. M., Kinney, J. H., et al. (1997) · Acta Materialia · doi:10.1016/s1359-6454(96)00311-4 · Cited by 105
Simultaneous Tomography and Diffraction Analysis of Creep Damage
Pyzalla, A. R., Camin, B., Buslaps, T., et al. (2005) · Science · doi:10.1126/science.1106778 · Cited by 105
Bernhardt, R., Scharnweber, D., Müller, B., et al. (2004) · European Cells and Materials · doi:10.22203/ecm.v007a05 · Cited by 104
Optical Fiber Imaging Based Tomographic Reconstruction of Burner Flames
Hossain, M. M., Lu, G., & Yan, Y. G. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2186477 · Cited by 104
Large-scale optical-field measurements with geometric fibre constructs
Abouraddy, A. F., Shapira, O., Bayındır, M., Arnold, J., Sorin, F., Hinczewski, D. S., Joannopoulos, J. D., & Fink, Y. (2006) · Nature Materials · doi:10.1038/nmat1674 · Cited by 104
Interface-specific x-ray phase retrieval tomography of complex biological organs
Beltran, M. A., Paganin, D. M., Siu, K. K. W., Fouras, A., Hooper, S. B., Reser, D. H., & Kitchen, M. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/23/002 · Cited by 104
Guided Wave Tomography on an Aircraft Wing with Leave in Place Sensors
Gao, H. (2005) · AIP conference proceedings · doi:10.1063/1.1916887 · Cited by 103
Size homeostasis in adherent cells studied by synthetic phase microscopy
Sung, Y., Tzur, A., Oh, S., Choi, W., Li, V. C., Dasari, R. R., Yaqoob, Z., & Kirschner, M. W. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315290110 · Cited by 95
Determination of tissue attenuation in emission tomography of optically dense media
Natterer, F. (1993) · Inverse Problems · doi:10.1088/0266-5611/9/6/009 · Cited by 103
Spiral interpolation algorithm for multislice spiral CT. I. Theory
Kalender, W. A., Fuchs, T., Krause, J., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887832 · Cited by 103
Emerging clinical applications of computed tomography
Schena, E., Liguori, C., Frauenfelder, G., Massaroni, C., Saccomandi, P., Giurazza, F., Pitocco, F., & Marano, R. (2015) · Medical Devices Evidence and Research · doi:10.2147/mder.s70630 · Cited by 114
Nielsen, S. F., Poulsen, H. F., Beckmann, F., et al. (2003) · Acta Materialia · doi:10.1016/s1359-6454(03)00053-3 · Cited by 102
High temperature permeability of fibrous materials using direct simulation Monte Carlo
Borner, A., Panerai, F., & Mansour, N. N. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.10.113 · Cited by 108
Application of electrical capacitance tomography in circulating fluidised beds – A review
Wang, H., & Yang, W. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115311 · Cited by 100
Buffière, J., Ferrié, E., Proudhon, H., et al. (2006) · Materials Science and Technology · doi:10.1179/174328406x114135 · Cited by 100
Mueller, K. D., Yagel, R., & Wheller, J. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.781017 · Cited by 99
Toward 4D mechanical correlation
Hild, F., Bouterf, A., Chamoin, L., et al. (2016) · Advanced Modeling and Simulation in Engineering Sciences · doi:10.1186/s40323-016-0070-z · Cited by 99
Fast X-Ray Fluorescence Microtomography of Hydrated Biological Samples
Lombi, E., de Jonge, M. D., Donner, E., Kopittke, P. M., Howard, D. L., Kirkham, R., Ryan, C. G., & Paterson, D. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020626 · Cited by 106
Fluorescent protein tomography scanner for small animal imaging
Zacharakis, G., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.843254 · Cited by 104
Enhancing images of shale formations by a hybrid stochastic and deep learning algorithm
Kamrava, S., Tahmasebi, P., & Sahimi, M. (2019) · Neural Networks · doi:10.1016/j.neunet.2019.07.009 · Cited by 106
Moffat, A. J., Wright, P. M., Buffière, J., et al. (2008) · Scripta Materialia · doi:10.1016/j.scriptamat.2008.07.034 · Cited by 97
Four-dimensional STEM-EELS: Enabling nano-scale chemical tomography
Jarausch, K., Thomas, P. J., Leonard, D. N., et al. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.12.012 · Cited by 97
Some aspects of array signal processing
Haykin, S., Reilly, J. P., Kezys, V., & Vertatschitsch, E. J. (1992) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1992.0001 · Cited by 115
Trends in hard X-ray fluorescence mapping: environmental applications in the age of fast detectors
Lombi, E., de Jonge, M. D., Donner, E., Ryan, C. G., & Paterson, D. J. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4829-2 · Cited by 102
Metadata
- Authors
- Kak, A. C., & Slaney, M.
- Affiliations
- Purdue University West Lafayette (US)
- ORCID
- Slaney, Malcolm
- Venue
- Society for Industrial and Applied Mathematics eBooks
- Published
- 2001-01-01
- OpenAlex
- W2037521346
- Cited by
- 5,809
- References
- 0
- Citations by year
- 2026: 83 · 2025: 106 · 2024: 111 · 2023: 132 · 2022: 112 · 2021: 204 · 2020: 203 · 2019: 216 · 2018: 221 · 2017: 224 · 2016: 252 · 2015: 289 · 2014: 277 · 2013: 286 · 2012: 282
- FWCI
- 38.59
- Type
- book
- Language
- en
- Open access
- closed
- Locations
- Society for Industrial and Applied Mathematics eBooks (publishedVersion)
- Topics
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microwave Imaging and Scattering Analysis
- Keywords
- computed tomography, tomography, cross-sectional imaging, transmission tomography, reflection tomography, diagnostic imaging, non-destructive testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.