Principles of Computerized Tomographic Imaging
The DOI matches its Crossref record.
Abstract
Tomography refers to the cross-sectional imaging of an object from either transmission or reflection data collected by illuminating the object from many different directions. The impact of tomography in diagnostic medicine has been revolutionary, since it has enabled doctors to view internal organs with unprecedented precision and safety to the patient. There are also numerous nonmedical imaging applications which lend themselves to methods of computerized tomography, such as mapping of underground resources...cross-sectional imaging of for nondestructive testing...the determination of the brightness distribution over a celestial sphere...three-dimensional imaging with electron microscopy. Principles of Computerized Tomographic Imaging provides a tutorial overview of topics in tomographic imaging covering mathematical principles and theory...how to apply the theory to problems in medical imaging and other fields...several variations of tomography that are currently being researched.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cited by
Items 201–300 of 1,006
Tomography of Reaction-Diffusion Microemulsions Reveals Three-Dimensional Turing Patterns
Bánsági, T., Vanag, V. K., & Epstein, I. R. (2011) · Science · doi:10.1126/science.1200815 · Cited by 174
Li, J., Zhou, N., Sun, J., Zhou, S., Bai, Z., Lu, L., Chen, Q., & Zuo, C. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00815-7 · Cited by 171
Krause, M., Hausherr, J. M., Burgeth, B., Herrmann, C., & Krenkel, W. (2010) · Journal of Materials Science · doi:10.1007/s10853-009-4016-4 · Cited by 169
Three-dimensional structure determination from a single view
Raines, K. S., Salha, S., Sandberg, R. L., Jiang, H., Rodríguez, J. A., Fahimian, B. P., Kapteyn, H. C., Du, J., & Miao, J. (2010) · Nature · doi:10.1038/nature08705 · Cited by 170
Bultreys, T., Boone, M. A., Boone, M. N., De Schryver, T., Masschaele, B., Van Hoorebeke, L., & Cnudde, V. (2016) · Advances in Water Resources · doi:10.1016/j.advwatres.2015.05.012 · Cited by 166
Fast microtomography using high energy synchrotron radiation
Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884194 · Cited by 169
Data acquisition and processing software package for Medipix2
Holy, T., Jakubek, J., Pospisil, S., Uher, J., Vavrik, D., & Vykydal, Z. (2006) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2006.01.122 · Cited by 169
Neutron imaging of hydrogen-rich fluids in geomaterials and engineered porous media: A review
Perfect, E., Cheng, C.-L., Kang, M., Bilheux, H. Z., Lamanna, J. M., Gragg, M. J., & Wright, D. M. (2014) · Earth-Science Reviews · doi:10.1016/j.earscirev.2013.11.012 · Cited by 168
Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice
Patwardhan, S. V., Bloch, S. R., Achilefu, S., & Culver, J. P. (2005) · Optics Express · doi:10.1364/opex.13.002564 · Cited by 168
Application of stochastic inverse theory to ionospheric tomography
Fremouw, E. J., Secan, J. A., & Howe, B. M. (1992) · Radio Science · doi:10.1029/92rs00515 · Cited by 164
Censor, Y., & Elfving, T. (2002) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/s089547980138705x · Cited by 162
Theory, Instrumentation, and Applications of Electron Paramagnetic Resonance Oximetry
Ahmad, R., & Kuppusamy, P. (2010) · Chemical Reviews · doi:10.1021/cr900396q · Cited by 166
Linking Morphology of Porous Media to Their Macroscopic Permeability by Deep Learning
Kamrava, S., Tahmasebi, P., & Sahimi, M. (2020) · Transport in Porous Media · doi:10.1007/s11242-019-01352-5 · Cited by 165
Wavelet Based Noise Reduction in CT-Images Using Correlation Analysis
Borsdorf, A., Raupach, R., Flohr, T., & Hornegger, J. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923983 · Cited by 164
Strong-field ionization with two-color circularly polarized laser fields
Mancuso, C. A., Hickstein, D. D., Grychtol, P., Knut, R., Kfir, O., Tong, X.-M., Dollar, F., Zusin, D., Gopalakrishnan, M., Gentry, C., et al. (2015) · Physical Review A · doi:10.1103/physreva.91.031402 · Cited by 164
Conjugate gradient method applied to inverse scattering problem
Harada, H., Wall, D. J. N., Takenaka, T., & Tanaka, M. (1995) · IEEE Transactions on Antennas and Propagation · doi:10.1109/8.402197 · Cited by 163
Quantitative 3D elemental microtomography of Cyclotella meneghiniana at 400-nm resolution
de Jonge, M. D., Holzner, C., Baines, S. B., Twining, B. S., Ignatyev, K., Diaz, J., Howard, D. L., Legnini, D., Miceli, A., McNulty, I., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001469107 · Cited by 161
Characterization and simulation of microstructure and properties of EPS lightweight concrete
Bouvard, D., Chaix, J. M., Dendievel, R., Fazekas, A., Létang, J. M., Peix, G., & Quenard, D. (2007) · Cement and Concrete Research · doi:10.1016/j.cemconres.2007.08.028 · Cited by 162
Would near-infrared fluorescence signals propagate through large human organs for clinical studies?
Ntziachristos, V., Ripoll, J., & Weissleder, R. (2002) · Optics Letters · doi:10.1364/ol.27.000333 · Cited by 161
Some properties of irregular 3-D particles
Taylor, M. A., Garboczi, E. J., Erdogan, S. T., & Fowler, D. W. (2006) · Powder Technology · doi:10.1016/j.powtec.2005.10.013 · Cited by 161
Wetzstein, G., Lanman, D., Heidrich, W., & Raskar, R. (2011) · ACM Transactions on Graphics · doi:10.1145/2010324.1964990 · Cited by 160
Voxel-Scale Digital Volume Correlation
Leclerc, H., Périé, J.-N., Roux, S., & Hild, F. (2011) · Experimental Mechanics · doi:10.1007/s11340-010-9407-6 · Cited by 161
Weiss, P., Obadia, L., Magne, D., Bourges, X., Rau, C., Weitkamp, T., Khairoun, I., Bouler, J. M., Chappard, D., Gauthier, O., et al. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00335-1 · Cited by 160
Diagnostics for plasma-based electron accelerators
Downer, M. C., Zgadzaj, R., Debus, A., Schramm, U., & Kaluza, M. C. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035002 · Cited by 159
Saghi, Z., Holland, D. J., Leary, R., Falqui, A., Bertoni, G., Sederman, A. J., Gladden, L. F., & Midgley, P. A. (2011) · Nano Letters · doi:10.1021/nl202253a · Cited by 159
Mahmood, F., & Durr, N. J. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.06.005 · Cited by 159
Phase-contrast microtomography with coherent high-energy synchrotron x rays
Raven, C., Snigirev, A., Snigireva, I., Spanne, P., Souvorov, A., & Kohn, V. (1996) · Applied Physics Letters · doi:10.1063/1.117446 · Cited by 158
Coregistered tomographic x-ray and optical breast imaging: initial results
Zhang, Q., Brukilacchio, T. J., Li, A., Stott, J. J., Chaves, T., Hillman, E. M. C., Wu, T., Chorlton, M., Rafferty, E. A., Moore, R. H., et al. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1899183 · Cited by 162
Internal elemental microanalysis combining x-ray fluorescence, Compton and transmission tomography
Golosio, B., Simionovici, A., Somogyi, A., Lemelle, L., Chukalina, M. V., & Brunetti, A. (2003) · Journal of Applied Physics · doi:10.1063/1.1578176 · Cited by 152
Development and trends in synchrotron studies of ancient and historical materials
Bertrand, L., Cotte, M., Stampanoni, M., Thoury, M., Marone, F., & Schöder, S. (2012) · Physics Reports · doi:10.1016/j.physrep.2012.03.003 · Cited by 174
Local anisotropy analysis of injection moulded fibre reinforced polymer composites
Bernasconi, A., Cosmi, F., & Dreossi, D. (2008) · Composites Science and Technology · doi:10.1016/j.compscitech.2008.05.022 · Cited by 176
Scalp and skull influence on near infrared photon propagation in the Colin27 brain template
Strangman, G. E., Zhang, Q., & Li, Z. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.090 · Cited by 168
Optical diffraction tomography techniques for the study of cell pathophysiology
Kim, K., Yoon, J., Shin, S., Lee, S., Yang, S.-A., & Park, Y. (2016) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe16.02.020201 · Cited by 174
Ultrafast dynamics observation during femtosecond laser-material interaction
Guo, B., Sun, J., Lu, Y., & Jiang, L. (2019) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ab3a24 · Cited by 165
Thermoacoustic tomography with correction for acoustic speed variations
Jin, X., & Wang, L. V. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/24/010 · Cited by 151
Microstructure and fracture in three dimensions
Landis, E. N., Nagy, E. N., & Keane, D. T. (2003) · Engineering Fracture Mechanics · doi:10.1016/s0013-7944(02)00157-1 · Cited by 151
X-ray microtomography of bones and teeth
Davis, G. R., & Wong, F. S. L. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/3/001 · Cited by 151
Ultrasonic Guided Wave Imaging Techniques in Structural Health Monitoring
Yan, F., Royer, R. L., & Rose, J. L. (2009) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x09356026 · Cited by 149
Dowker, S. E. P., Davis, G. R., & Elliott, J. C. (1997) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/s1079-2104(97)90155-4 · Cited by 149
Sparse representation-based synthetic aperture radar imaging
Samadi, S., Çetin, M., & Masnadi-Shirazi, M. A. (2010) · IET Radar Sonar & Navigation · doi:10.1049/iet-rsn.2009.0235 · Cited by 158
Experimental Observation and Analysis of Inverse Transients for Pipeline Leak Detection
Vítkovský, J. P., Lambert, M. F., Simpson, A. R., & Liggett, J. A. (2007) · Journal of Water Resources Planning and Management · doi:10.1061/(asce)0733-9496(2007)133:6(519 · Cited by 156
Wetzstein, G., Lanman, D. R., Heidrich, W., & Raskar, R. (2011) · ACM SIGGRAPH Conference (SIGGRAPH) · doi:10.1145/1964921.1964990 · Cited by 152
Time-multiplexed structured illumination using a DMD for optical diffraction tomography
Lee, K., Kim, K., Kim, G., Shin, S., & Park, Y. (2017) · Optics Letters · doi:10.1364/ol.42.000999 · Cited by 149
Ranut, P., Nobile, E., & Mancini, L. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.11.056 · Cited by 158
Non-line-of-sight Imaging with Partial Occluders and Surface Normals
Heide, F., O’Toole, M., Zang, K., Lindell, D. B., Diamond, S., & Wetzstein, G. (2019) · ACM Transactions on Graphics · doi:10.1145/3269977 · Cited by 183
An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT
Poludniowski, G. G., Evans, P., Hansen, V. N., & Webb, S. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/12/016 · Cited by 156
Diffuse optical tomography with a priori anatomical information
Murat Guven, A., Yazıcı, B., Intes, X., & Chance, B. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/008 · Cited by 166
Ray Contribution Masks for Structure Adaptive Sinogram Filtering
Balda, M., Hornegger, J., & Heismann, B. J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2187213 · Cited by 156
Progress in In Situ X-Ray Tomographic Microscopy of Liquid Water in Gas Diffusion Layers of PEFC
Eller, J., Rosén, T., Marone, F., Stampanoni, M., Wokaun, A. J., & Büchi, F. N. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3596556 · Cited by 187
du Plessis, A., le Roux, S. G., & Guelpa, A. (2016) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2016.08.005 · Cited by 142
Schulz, G. V., Weitkamp, T., Zanette, I., Pfeiffer, F., Beckmann, F., Dávid, C., Rutishauser, S., Reznikova, E. F., & Müller, B. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0281 · Cited by 141
Villarraga-Gómez, H., Lee, C., & Smith, S. T. (2017) · Precision Engineering · doi:10.1016/j.precisioneng.2017.08.021 · Cited by 149
Ntziachristos, V., Ma, X., & Chance, B. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149235 · Cited by 142
High temporal resolution and streak-free four-dimensional cone-beam computed tomography
Leng, S., Tang, J., Zambelli, J. N., Nett, B. E., Tolakanahalli, R., & Chen, G. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/20/006 · Cited by 156
Image reconstruction for PET/CT scanners: past achievements and future challenges
Tong, S., Alessio, A. M., & Kinahan, P. E. (2010) · Imaging in Medicine · doi:10.2217/iim.10.49 · Cited by 138
Nicolas, F., Todoroff, V., Plyer, A., Besnerais, G. L., Donjat, D., Micheli, F., Champagnat, F., Cornic, P., & Sant, Y. L. (2015) · Experiments in Fluids · doi:10.1007/s00348-015-2100-x · Cited by 149
In Vivo Tomographic Imaging of Near-Infrared Fluorescent Probes
Ntziachristos, V., Bremer, C., Graves, E. E., Ripoll, J., & Weissleder, R. (2002) · Molecular Imaging · doi:10.1162/153535002320162732 · Cited by 141
Paltauf, G., Nuster, R., Haltmeier, M., et al. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/6/s07 · Cited by 138
High-performance 4-nm-resolution X-ray tomography using burst ptychography
Aidukas, T., Phillips, N., Díaz, A., et al. (2024) · Nature · doi:10.1038/s41586-024-07615-6 · Cited by 138
Tomography of the ionosphere: Four‐dimensional simulations
Howe, B. M., Runciman, K., & Secan, J. A. (1998) · Radio Science · doi:10.1029/97rs02615 · Cited by 138
Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation
Ning, Y., Tang, X., Conover, D. L., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887842 · Cited by 138
Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits
Kudo, H., & Saito, T. R. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.276158 · Cited by 138
High-resolution three-dimensional structural microscopy by single-angle Bragg ptychography
Hruszkewycz, S. O., Allain, M., Holt, M. V., Murray, C. E., Holt, J. R., Fuoss, P. H., & Chamard, V. (2016) · Nature Materials · doi:10.1038/nmat4798 · Cited by 137
Elbakri, I. A., & Fessler, J. A. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/314 · Cited by 137
Accurate image reconstruction from few-view and limited-angle data in diffraction tomography
LaRoque, S. J., Sidky, E. Y., & Pan, X. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.001772 · Cited by 156
MRI-guided optical tomography: prospects and computation for a new imaging method
Barbour, R. L., Graber, H. L., Chang, J., Barbour, S.-L. S., Koo, P. C., & Aronson, R. (1995) · IEEE Computational Science and Engineering · doi:10.1109/99.476370 · Cited by 135
Computational resources for cryo-electron tomography in Bsoft
Heymann, J. B., Giovanni Cardone, A., Winkler, D. C., & Steven, A. C. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.08.002 · Cited by 138
Deep-Learning-Based Image Reconstruction and Enhancement in Optical Microscopy
Haan, K. D., Rivenson, Y., Wu, Y., & Özcan, A. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2949575 · Cited by 159
Anatomical background and generalized detectability in tomosynthesis and cone‐beam CT
Gang, G. J., Tward, D. J., Lee, J., et al. (2010) · Medical Physics · doi:10.1118/1.3352586 · Cited by 134
Joseph, D. K., Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2006) · Applied Optics · doi:10.1364/ao.45.008142 · Cited by 152
An ultra fast electron beam x-ray tomography scanner
Fischer, F., Hoppe, D., Schleicher, E., et al. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/9/094002 · Cited by 133
Alumbaugh, D., Chang, P., Paprocki, L., et al. (2002) · Water Resources Research · doi:10.1029/2001wr000754 · Cited by 133
Low‐dose phase contrast mammography with conventional x‐ray sources
Olivo, A., Gkoumas, S., Endrizzi, M., Hagen, C. K., Szafraniec, M. B., Diémoz, P. C., Munro, P. R. T., Ignatyev, K., Johnson, B., Horrocks, J. A., et al. (2013) · Medical Physics · doi:10.1118/1.4817480 · Cited by 136
Changing soil and surface conditions during rainfall
Fohrer, N., Berkenhagen, J. H., Hecker, J.-M., et al. (1999) · CATENA · doi:10.1016/s0341-8162(99)00026-0 · Cited by 131
Advances in PET Image Reconstruction
Reader, A. J., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.08.001 · Cited by 130
Erdoğan, S. T., Quiroga, P. N., Fowler, D. W., et al. (2006) · Cement and Concrete Research · doi:10.1016/j.cemconres.2006.04.003 · Cited by 130
Mueller, K., & Yagel, R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897815 · Cited by 129
Pelt, D. M., Gürsoy, D., Palenstijn, W. J., Sijbers, J., Carlo, F. D., & Batenburg, K. J. (2016) · Journal of Synchrotron Radiation · doi:10.1107/s1600577516005658 · Cited by 128
Unconventional methods of imaging: computational microscopy and compact implementations
McLeod, E. J., & Özcan, A. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/7/076001 · Cited by 129
Image Processing Handbook, Fourth Edition
Russ, J. C. (2002) · Cited by 187
Trtik, P., Münch, B., Weiss, J., et al. (2011) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2011.02.012 · Cited by 128
Shape analysis of a reference cement
Garboczi, E. J., & Bullard, J. W. (2004) · Cement and Concrete Research · doi:10.1016/j.cemconres.2004.01.006 · Cited by 128
TIMBIR: A Method for Time-Space Reconstruction From Interlaced Views
Mohan, K. A., Venkatakrishnan, S. V., Gibbs, J. W., Gulsoy, E. B., Xiao, X., Graef, M. D., Voorhees, P. W., & Bouman, C. A. (2015) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2015.2431913 · Cited by 129
Evaluation of the spatial resolution characteristics of a cone‐beam breast CT scanner
Kwan, A. L. C., Boone, J. M., Yang, K., & Huang, S. (2006) · Medical Physics · doi:10.1118/1.2400830 · Cited by 129
Pelt, D. M., Batenburg, K. J., & Sethian, J. A. (2018) · Journal of Imaging · doi:10.3390/jimaging4110128 · Cited by 143
Neutron imaging of lithium batteries
Ziesche, R. F., Kardjilov, N., Kockelmann, W. A., Brett, D. J. L., & Shearing, P. R. (2022) · Joule · doi:10.1016/j.joule.2021.12.007 · Cited by 141
Neutron tomography: Method and applications
Vontobel, P., Lehmann, E. H., Hassanein, R., & Frei, G. (2006) · Physica B Condensed Matter · doi:10.1016/j.physb.2006.05.252 · Cited by 133
Brun, F., Pacilè, S., Accardo, A., Kourousias, G., Dreossi, D., Mancini, L., Tromba, G., & Pugliese, R. (2015) · Fundamenta Informaticae · doi:10.3233/fi-2015-1273 · Cited by 132
The Three-Dimensional Morphology of Growing Dendrites
Gibbs, J. W., Mohan, K. A., Gulsoy, E. B., Shahani, A. J., Xiao, X., Bouman, C. A., Graef, M. D., & Voorhees, P. W. (2015) · Scientific Reports · doi:10.1038/srep11824 · Cited by 139
A noninvasive X-ray technique for determination of liquid holdup in a rotating packed bed
Yang, Y., Xiang, Y., Chu, G., et al. (2015) · Chemical Engineering Science · doi:10.1016/j.ces.2015.07.044 · Cited by 125
Ultrahigh-Resolution X-ray Tomography
Haddad, W. S., McNulty, I., Trebes, J. E., et al. (1994) · Science · doi:10.1126/science.266.5188.1213 · Cited by 125
Nolf, W. D., Vanmeert, F., & Janssens, K. (2014) · Journal of Applied Crystallography · doi:10.1107/s1600576714008218 · Cited by 125
Busse, M., Müller, M., Kimm, M. A., Ferstl, S., Allner, S., Achterhold, K., Herzen, J., & Pfeiffer, F. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1720862115 · Cited by 130
Artefacts in X-ray microtomography of materials
Davis, G. R., & Elliott, J. C. (2006) · Materials Science and Technology · doi:10.1179/174328406x114117 · Cited by 124
Deán‐Ben, X. L., & Razansky, D. (2016) · Photoacoustics · doi:10.1016/j.pacs.2016.10.001 · Cited by 126
Lamb wave tomography of pipe-like structures
Leonard, K. R., & Hinders, M. K. (2005) · Ultrasonics · doi:10.1016/j.ultras.2004.12.006 · Cited by 123
Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomography
Krumm, M., Kasperl, S., & Franz, M. (2008) · NDT & E International · doi:10.1016/j.ndteint.2007.12.001 · Cited by 123
A resolution criterion for electron tomography based on cross-validation
Giovanni Cardone, A., Grünewald, K., & Steven, A. C. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.04.006 · Cited by 128
Evolution of porosity and geochemistry in Marcellus Formation black shale during weathering
Jin, L., Mathur, R. D., Rother, G., Cole, D. R., Bazilevskaya, E. A., Williams, J. Z., Carone, A., & Brantley, S. L. (2013) · Chemical Geology · doi:10.1016/j.chemgeo.2013.07.012 · Cited by 124
Synchrotron X-ray techniques for fluid dynamics
Kastengren, A., & Powell, C. F. (2014) · Experiments in Fluids · doi:10.1007/s00348-014-1686-8 · Cited by 122
Metadata
- Authors
- Kak, A. C., & Slaney, M.
- Affiliations
- Purdue University West Lafayette (US)
- ORCID
- Slaney, Malcolm
- Venue
- Society for Industrial and Applied Mathematics eBooks
- Published
- 2001-01-01
- OpenAlex
- W2037521346
- Cited by
- 5,809
- References
- 0
- Citations by year
- 2026: 83 · 2025: 106 · 2024: 111 · 2023: 132 · 2022: 112 · 2021: 204 · 2020: 203 · 2019: 216 · 2018: 221 · 2017: 224 · 2016: 252 · 2015: 289 · 2014: 277 · 2013: 286 · 2012: 282
- FWCI
- 38.59
- Type
- book
- Language
- en
- Open access
- closed
- Locations
- Society for Industrial and Applied Mathematics eBooks (publishedVersion)
- Topics
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microwave Imaging and Scattering Analysis
- Keywords
- computed tomography, tomography, cross-sectional imaging, transmission tomography, reflection tomography, diagnostic imaging, non-destructive testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.