Principles of Computerized Tomographic Imaging
The DOI matches its Crossref record.
Abstract
Tomography refers to the cross-sectional imaging of an object from either transmission or reflection data collected by illuminating the object from many different directions. The impact of tomography in diagnostic medicine has been revolutionary, since it has enabled doctors to view internal organs with unprecedented precision and safety to the patient. There are also numerous nonmedical imaging applications which lend themselves to methods of computerized tomography, such as mapping of underground resources...cross-sectional imaging of for nondestructive testing...the determination of the brightness distribution over a celestial sphere...three-dimensional imaging with electron microscopy. Principles of Computerized Tomographic Imaging provides a tutorial overview of topics in tomographic imaging covering mathematical principles and theory...how to apply the theory to problems in medical imaging and other fields...several variations of tomography that are currently being researched.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cited by
Items 101–200 of 1,006
Tomographic mammography using a limited number of low‐dose cone‐beam projection images
Wu, T., Stewart, A., Stanton, M., McCauley, T., Phillips, W., Kopans, D. B., Moore, R. H., Eberhard, J. W., Opsahl‐Ong, B., Niklason, L., et al. (2003) · Medical Physics · doi:10.1118/1.1543934 · Cited by 302
Bakavos, D., & Prangnell, P. B. (2010) · Materials Science and Engineering: A · doi:10.1016/j.msea.2010.06.038 · Cited by 294
Neutron imaging in materials science
Kardjilov, N., Manke, I., Hilger, A., Strobl, M., & Banhart, J. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70139-0 · Cited by 286
History, current state, and future directions of ionospheric imaging
Bust, G. S., & Mitchell, C. N. (2008) · Reviews of Geophysics · doi:10.1029/2006rg000212 · Cited by 284
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
Compressed sensing electron tomography
Leary, R., Saghi, Z., Midgley, P. A., & Holland, D. J. (2013) · Ultramicroscopy · doi:10.1016/j.ultramic.2013.03.019 · Cited by 281
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
Chen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q., & Longo, R. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512029731 · Cited by 279
ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A. (2011) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511002895 · Cited by 278
The ICON beamline – A facility for cold neutron imaging at SINQ
Kaestner, A. P., Hartmann, S., Kühne, G., Frei, G., Grünzweig, C., Josic, L., Schmid, F., & Lehmann, E. H. (2011) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2011.08.022 · Cited by 274
3D imaging of nanomaterials by discrete tomography
Batenburg, K. J., Bals, S., Sijbers, J., Kübel, C., Midgley, P. A., Hernandez, J. C., Kaiser, U., Encina, E. R., Coronado, E. A., & Van Tendeloo, G. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.01.009 · Cited by 277
A synchrotron radiation microtomography system for the analysis of trabecular bone samples
Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999) · Medical Physics · doi:10.1118/1.598736 · Cited by 275
Through-wall imaging: Historical perspective and future directions
Baranoski, E. J. (2008) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2008.01.005 · Cited by 270
Iterative reconstruction algorithm for optoacoustic imaging
Paltauf, G., Viator, J. A., Prahl, S. A., & Jacques, S. L. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1501898 · Cited by 269
A New Wavelet Denoising Method for Selecting Decomposition Levels and Noise Thresholds
Srivastava, M., Anderson, C. L., & Freed, J. H. (2016) · IEEE Access · doi:10.1109/access.2016.2587581 · Cited by 268
In Introductory Review to THz Non-Destructive Testing of Composite Mater
Amenabar, I., Lopez, F., & Mendikute, A. (2013) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-012-9949-z · Cited by 264
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Introduction to Microwave Imaging
Nikolova, N. K. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316084267 · Cited by 263
Line detection in images through regularized hough transform
Aggarwal, N., & Karl, W. C. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.863021 · Cited by 260
Characterization and simulation of microstructure and thermal properties of foamed concrete
Wei, S., Yiqiang, C., Yunsheng, Z., & Jones, M. R. (2013) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2013.06.027 · Cited by 259
Megavoltage CT on a tomotherapy system
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/10/316 · Cited by 261
Deep-Neural-Network-Based Sinogram Synthesis for Sparse-View CT Image Reconstruction
Lee, H., Lee, J., Kim, H., Cho, B., & Cho, S. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2867611 · Cited by 261
Living specimen tomography by digital holographic microscopy: morphometry of testate amoeba
Charrière, F., Pavillon, N., Colomb, T., Depeursinge, C., Heger, T. J., Mitchell, E. A. D., Marquet, P., & Rappaz, B. (2006) · Optics Express · doi:10.1364/oe.14.007005 · Cited by 257
X-Ray Tomography for Lithium Ion Battery Research: A Practical Guide
Pietsch, P., & Wood, V. (2017) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070616-123957 · Cited by 255
DuDoNet: Dual Domain Network for CT Metal Artifact Reduction
Lin, W.-A., Liao, H., Peng, C., Sun, X., Zhang, J., Luo, J., Chellappa, R., & Zhou, S. K. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.01076 · Cited by 254
Contrast maximisation based technique for 2-D ISAR autofocusing
Martorella, M., Berizzi, F., & Haywood, B. (2005) · IEE Proceedings - Radar, Sonar and Navigation · doi:10.1049/ip-rsn:20045123 · Cited by 250
Wang, S., & Zhang, X.-C. (2004) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/37/4/r01 · Cited by 249
Jennings, H. M., Bullard, J. W., Thomas, J. J., Andrade, J. E., Chen, J. J., & Scherer, G. W. (2008) · Journal of Advanced Concrete Technology · doi:10.3151/jact.6.5 · Cited by 249
Octopus, a fast and user-friendly tomographic reconstruction package developed in LabView®
Dierick, M., Masschaele, B., & Hoorebeke, L. V. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/7/020 · Cited by 247
DRONE: Dual-Domain Residual-based Optimization NEtwork for Sparse-View CT Reconstruction
Wu, W., Hu, D., Niu, C., Yu, H., Vardhanabhuti, V., & Wang, G. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3078067 · Cited by 241
Statistical Image Reconstruction Methods for Transmission Tomography
Fessler, J. (2010) · Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis · doi:10.1117/3.831079.ch1 · Cited by 240
Mir, M., Bhaduri, B., Wang, R., Zhu, R., & Popescu, G. (2012) · Progress in Optics · doi:10.1016/b978-0-44-459422-8.00003-5 · Cited by 232
Moeck, J. P., Bourgouin, J.-F., Durox, D., Schuller, T., & Candel, S. (2012) · Combustion and Flame · doi:10.1016/j.combustflame.2012.04.002 · Cited by 234
Developments in synchrotron x-ray computed microtomography at the National Synchrotron Light Source:
Dowd, B. A., Campbell, G. H., Marr, R. B., Nagarkar, V. V., Tipnis, S. V., Axe, L., & Siddons, D. P. (1999) · SPIE Proceedings · doi:10.1117/12.363725 · Cited by 232
X-ray computed tomography: from medical imaging to dimensional metrology
Villarraga-Gómez, H., Herazo, E. L., & Smith, S. T. (2019) · Precision Engineering · doi:10.1016/j.precisioneng.2019.06.007 · Cited by 233
Laser absorption spectroscopy for combustion diagnosis in reactive flows: A review
Liu, C., & Xu, L. (2019) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1448854 · Cited by 230
Kardjilov, N., Manke, I., Woracek, R., Hilger, A., & Banhart, J. (2018) · Materials Today · doi:10.1016/j.mattod.2018.03.001 · Cited by 230
Baker, D. R., Mancini, L., Polacci, M., Higgins, M. D., Gualda, G. A. R., Hill, R. J., & Rivers, M. L. (2012) · Lithos · doi:10.1016/j.lithos.2012.06.008 · Cited by 227
Micro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
A review on image reconstruction algorithms for electrical capacitance/resistance tomography
Cui, Z., Wang, Q., Xue, Q., Fan, W., Zhang, L., Cao, Z., Sun, B., Wang, H., & Yang, W. (2016) · Sensor Review · doi:10.1108/sr-01-2016-0027 · Cited by 228
Chen, P., Huang, J., & Zhang, X. (2013) · Inverse Problems · doi:10.1088/0266-5611/29/2/025011 · Cited by 224
3D Forward and Back-Projection for X-Ray CT Using Separable Footprints
Long, Y., Fessler, J. A., & Balter, J. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2050898 · Cited by 228
Model based processing of signals: a state space approach
Rao, B. D., & Arun, K. S. (1992) · Proceedings of the IEEE · doi:10.1109/5.123298 · Cited by 224
Imaging and image processing in porous media research
Kaestner, A., Lehmann, E., & Stampanoni, M. (2008) · Advances in Water Resources · doi:10.1016/j.advwatres.2008.01.022 · Cited by 225
Hay, T. R., Royer, R. L., Gao, H., Zhao, X., & Rose, J. L. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/4/007 · Cited by 223
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing
Chen, Y., Yin, X., Shi, L., Shu, H., Luo, L., Coatrieux, J.-L., & Toumoulin, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5803 · Cited by 223
A Review of X-Ray Flow Visualization With Applications to Multiphase Flows
Heindel, T. J. (2011) · Journal of Fluids Engineering · doi:10.1115/1.4004367 · Cited by 217
A geometric calibration method for cone beam CT systems
Yang, K., Kwan, A. L. C., Miller, D. F., & Boone, J. M. (2006) · Medical Physics · doi:10.1118/1.2198187 · Cited by 217
Izzo, J. R., Joshi, A. S., Grew, K. N., Chiu, W. K. S., Tkachuk, A., Wang, S. H., & Yun, W. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2895067 · Cited by 216
Goldhahn, E., & Seume, J. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0331-1 · Cited by 212
An Online Plug-and-Play Algorithm for Regularized Image Reconstruction
Sun, Y., Wohlberg, B., & Kamilov, U. S. (2019) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2019.2893568 · Cited by 207
Multiresolution Monogenic Signal Analysis Using the Riesz–Laplace Wavelet Transform
Unser, M., Sage, D., & Van De Ville, D. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2027628 · Cited by 210
Development of a GNSS water vapour tomography system using algebraic reconstruction techniques
Bender, M., Dick, G., Ge, M., Deng, Z., Wickert, J., Kahle, H.-G., Raabe, A., & Tetzlaff, G. (2011) · Advances in Space Research · doi:10.1016/j.asr.2010.05.034 · Cited by 210
Three-Dimensional Analysis of Vascular Development in the Mouse Embryo
Walls, J. R., Coultas, L., Rossant, J., & Henkelman, R. M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002853 · Cited by 208
Chouzenoux, E., Pesquet, J.-C., & Repetti, A. (2014) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-013-0465-7 · Cited by 206
Computational Analysis and Improvement of SIRT
Gregor, J., & Benson, T. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923696 · Cited by 206
Wide-field high-resolution 3D microscopy with Fourier ptychographic diffraction tomography
Zuo, C., Sun, J., Li, J., Asundi, A., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106003 · Cited by 205
Transparent and Specular Object Reconstruction
Ihrke, I., Kutulakos, K. N., Lensch, H. P. A., Magnor, M., & Heidrich, W. (2010) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2010.01753.x · Cited by 203
Structural Analysis of Macromolecular Assemblies by Electron Microscopy
Orlova, E. V., & Saibil, H. R. (2011) · Chemical Reviews · doi:10.1021/cr100353t · Cited by 205
UGCT: New X-ray radiography and tomography facility
Masschaele, B. C., Cnudde, V., Dierick, M., Jacobs, P., Van Hoorebeke, L., & Vlassenbroeck, J. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.05.099 · Cited by 204
The morphology of anisotropic 3D-printed hydroxyapatite scaffolds
Fierz, F. C., Beckmann, F., Huser, M., Irsen, S. H., Leukers, B., Witte, F., Degistirici, Ö., Andronache, A., Thie, M., & Müller, B. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.012 · Cited by 203
Elad, M., Matalon, B., & Zibulevsky, M. (2007) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2007.02.002 · Cited by 201
Cone-Beam Reconstruction Using Filtered Backprojection
Turbell, H. (2001) · Cited by 199
Overview of methods for image reconstruction from projections in emission computed tomography
Lewitt, R. M., & Matej, S. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817882 · Cited by 200
Habaza, M., Gilboa, B., Roichman, Y., & Shaked, N. T. (2015) · Optics Letters · doi:10.1364/ol.40.001881 · Cited by 196
Time-resolved 3d capture of non-stationary gas flows
Atcheson, B., Ihrke, I., Heidrich, W., Tevs, A., Bradley, D., Magnor, M., & Seidel, H.-P. (2008) · ACM Transactions on Graphics · doi:10.1145/1409060.1409085 · Cited by 195
High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
Zhao, Y., Brun, E., Coan, P., Huang, Z., Sztrókay, A., Diemoz, P. C., Liebhardt, S., Mittone, A., Gasilov, S., Miao, J., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204460109 · Cited by 195
Bertels, S. P., DiCarlo, D. A., & Blunt, M. J. (2001) · Water Resources Research · doi:10.1029/2000wr900316 · Cited by 194
Rack, A., Zabler, S., Müller, B. R., Riesemeier, H., Weidemann, G., Lange, A., Goebbels, J., Hentschel, M., & Görner, W. (2008) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.11.020 · Cited by 193
Ultrasonic Lamb wave tomography in structural health monitoring
Zhao, X., Royer, R. L., Owens, S. E., & Rose, J. L. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/10/105002 · Cited by 191
Sharp, G. C., Kandasamy, N., Singh, H., & Folkert, M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/19/003 · Cited by 190
Ludwig, W., Buffière, J.-Y., Savelli, S., & Cloetens, P. (2003) · Acta Materialia · doi:10.1016/s1359-6454(02)00320-8 · Cited by 190
Capillary-Dominated Fluid Displacement in Porous Media
Singh, K., Jung, M., Brinkmann, M., & Seemann, R. (2019) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010518-040342 · Cited by 188
Graph Laplacian Tomography From Unknown Random Projections
Coifman, R. R., Shkolnisky, Y., Sigworth, F. J., & Singer, A. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2002305 · Cited by 184
Zhang, P., Wittmann, F. H., Lura, P., Müller, H. S., Han, S., & Zhao, T. (2018) · Cement and Concrete Research · doi:10.1016/j.cemconres.2018.03.003 · Cited by 187
Three-dimensional imaging of integrated circuits with macro- to nanoscale zoom
Holler, M., Odstrcil, M., Guizar-Sicairos, M., Lebugle, M., Müller, E., Finizio, S., Tinti, G., David, C., Zusman, J., Unglaub, W., et al. (2019) · Nature Electronics · doi:10.1038/s41928-019-0309-z · Cited by 185
Compressive sensing in medical imaging
Graff, C. G., & Sidky, E. Y. (2015) · Applied Optics · doi:10.1364/ao.54.000c23 · Cited by 184
Hard-x-ray microscopy with Fresnel zone plates reaches 40nm Rayleigh resolution
Chu, Y. S., Yi, J. M., De Carlo, F., Shen, Q., Lee, W.-K., Wu, H. J., Wang, C. L., Wang, J. Y., Liu, C. J., Wang, C. H., et al. (2008) · Applied Physics Letters · doi:10.1063/1.2857476 · Cited by 184
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · SPIE Proceedings · doi:10.1117/12.589146 · Cited by 180
Nanoscale Hard X-Ray Microscopy Methods for Materials Studies
Holt, M., Harder, R., Winarski, R., & Rose, V. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121654 · Cited by 183
Radio Frequency Tomography for Tunnel Detection
Lo Monte, L., Erricolo, D., Soldovieri, F., & Wicks, M. C. (2010) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2009.2029341 · Cited by 184
From 2-dimensional cephalograms to 3-dimensional computed tomography scans
Halazonetis, D. J. (2005) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.01.004 · Cited by 183
Wavelength-tuning interferometry of intraocular distances
Lexer, F., Hitzenberger, C. K., Fercher, A. F., & Kulhavy, M. (1997) · Applied Optics · doi:10.1364/ao.36.006548 · Cited by 182
Withayachumnankul, W., Png, G. M., Yin, X., Atakaramians, S., Jones, I., Lin, H., Ung, B. S. Y., Balakrishnan, J., Ng, B. W.-H., Ferguson, B., et al. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.900325 · Cited by 179
Tomographic techniques for the study of exceptionally preserved fossils
Sutton, M. D. (2008) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2008.0263 · Cited by 179
A Simple Low-Dose X-Ray CT Simulation From High-Dose Scan
Zeng, D., Huang, J., Bian, Z., Niu, S., Zhang, H., Feng, Q., Liang, Z., & Ma, J. (2015) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2015.2467219 · Cited by 179
In-vitro tomography and non-destructive imaging at depth of pharmaceutical solid dosage forms
ZEITLER, J., & GLADDEN, L. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.08.012 · Cited by 177
A General Local Reconstruction Approach Based on a Truncated Hilbert Transform
Ye, Y., Yu, H., Wei, Y., & Wang, G. (2007) · International Journal of Biomedical Imaging · doi:10.1155/2007/63634 · Cited by 176
Equally sloped tomography with oversampling reconstruction
Miao, J., Förster, F., & Levi, O. (2005) · Physical Review B · doi:10.1103/physrevb.72.052103 · Cited by 178
Real-time visualization of 3-D dynamic microscopic objects using optical diffraction tomography
Kim, K., Kim, K. S., Park, H., Ye, J. C., & Park, Y. (2013) · Optics Express · doi:10.1364/oe.21.032269 · Cited by 173
O(N/sup 2/log/sub 2/N) filtered backprojection reconstruction algorithm for tomography
Basu, S., & Bresler, Y. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.869187 · Cited by 175
Imaging of concrete structures
Büyüköztürk, O. (1998) · NDT & E International · doi:10.1016/s0963-8695(98)00012-7 · Cited by 174
Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
Livyatan, H., Yaniv, Z., & Joskowicz, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819288 · Cited by 176
Fluorescence Molecular Tomography: Principles and Potential for Pharmaceutical Research
Stuker, F., Ripoll, J., & Rudin, M. (2011) · Pharmaceutics · doi:10.3390/pharmaceutics3020229 · Cited by 173
Brantley, S. L., Holleran, M. E., Jin, L., & Bazilevskaya, E. (2013) · Earth Surface Processes and Landforms · doi:10.1002/esp.3415 · Cited by 173
Three dimensional experimental and numerical multiscale analysis of a fatigue crack
Rannou, J., Limodin, N., Réthoré, J., Gravouil, A., Ludwig, W., Baïetto-Dubourg, M.-C., Buffière, J.-Y., Combescure, A., Hild, F., & Roux, S. (2010) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.09.013 · Cited by 175
Towards quantitative 3D imaging of the osteocyte lacuno-canalicular network
Schneider, P., Meier, M., Wepf, R., & Müller, R. (2010) · Bone · doi:10.1016/j.bone.2010.07.026 · Cited by 172
Three-dimensional imaging system based on Fourier transform synthetic aperture focusing technique
Mayer, K., Marklein, R., Langenberg, K. J., & Kreutter, T. (1990) · Ultrasonics · doi:10.1016/0041-624x(90)90091-2 · Cited by 174
Debailleul, M., Georges, V., Simon, B., Morin, R., & Haeberlé, O. (2009) · Optics Letters · doi:10.1364/ol.34.000079 · Cited by 171
Hard X-ray fluorescence tomography—an emerging tool for structural visualization
de Jonge, M. D., & Vogt, S. (2010) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2010.09.002 · Cited by 172
Metadata
- Authors
- Kak, A. C., & Slaney, M.
- Affiliations
- Purdue University West Lafayette (US)
- ORCID
- Slaney, Malcolm
- Venue
- Society for Industrial and Applied Mathematics eBooks
- Published
- 2001-01-01
- OpenAlex
- W2037521346
- Cited by
- 5,809
- References
- 0
- Citations by year
- 2026: 83 · 2025: 106 · 2024: 111 · 2023: 132 · 2022: 112 · 2021: 204 · 2020: 203 · 2019: 216 · 2018: 221 · 2017: 224 · 2016: 252 · 2015: 289 · 2014: 277 · 2013: 286 · 2012: 282
- FWCI
- 38.59
- Type
- book
- Language
- en
- Open access
- closed
- Locations
- Society for Industrial and Applied Mathematics eBooks (publishedVersion)
- Topics
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microwave Imaging and Scattering Analysis
- Keywords
- computed tomography, tomography, cross-sectional imaging, transmission tomography, reflection tomography, diagnostic imaging, non-destructive testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.