CoChat

Validation of the Kenz Lifecorder EX and ActiGraph GT1M accelerometers for walking and running in adults

Abel, Mark G., Hannon, James C., Sell, Katie, Lillie, Tia, Conlin, Geri, Anderson, David · 2008 · Applied Physiology, Nutrition, and Metabolism
Cited by 134

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Accelerometer-based activity monitors are commonly used by researchers and clinicians to assess physical activity. Recently, the Kenz Lifecorder EX (KL) and ActiGraph GT1M (AG) accelerometers have been made commercially available, but there is limited research on the validity of these devices. Therefore, we sought to validate step count, activity energy expenditure (EE), and total EE output from the KL and AG during treadmill walking and running. Ten male and 10 female participants performed 10 min treadmill walking and running trials, at speeds of 54, 80, 107, 134, 161, and 188 m·min–1. Step counts were hand tallied by 2 observers, and indirect calorimetry was used to validate the accelerometers’ estimates of EE. AG total EE was calculated using the Freedson equation. Analysis of variance (ANOVA) and Pearson’s correlations were used to analyze the data. At the slowest walking speed, the AG and KL counted 64% ± 15% and 92% ± 6% of the observed steps, respectively. At all other treadmill speeds, both activity monitors undercounted, compared with observed steps, by ≤3%. The KL underestimated activity EE at faster running speeds (p < 0.01), overestimated total EE at some walking speeds, and underestimated total EE at some running speeds (p < 0.01). The Freedson equation inaccurately measured total EE at most walking and running speeds. The KL and the AG are moderately priced accelerometers that provide researchers and clinicians with accurate estimates of step counts and activity EE at most walking and running speeds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1139/h08-103

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 134

Metadata

Authors
Abel, M. G., Hannon, J. C., Sell, K., Lillie, T., Conlin, G., & Anderson, D.
Venue
Applied Physiology, Nutrition, and Metabolism
Published
2008-12
Volume
33
Issue
6
Pages
1155-1164
ISSN
  • 1715-5312 (ISSN-L)
  • 1715-5320
OpenAlex
W2166402494
Cited by
134
References
6
FWCI
3.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the Kenz Lifecorder EX and ActiGraph GT1M accelerometers for walking and running in adults. https://app.cochat.ai/papers/10.1139/h08-103
The paper
Abel, M. G., Hannon, J. C., Sell, K., Lillie, T., Conlin, G., & Anderson, D. (2008). Validation of the Kenz Lifecorder EX and ActiGraph GT1M accelerometers for walking and running in adults. Applied Physiology, Nutrition, and Metabolism. https://doi.org/10.1139/h08-103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.