CoChat

A New Measurement of Tissue Capillarity: The Capillary-to-Fibre Perimeter Exchange Index

Hepple, Russell T. · 1997 · Canadian Journal of Applied Physiology
Cited by 93

The DOI matches its Crossref record.

Abstract

The surface area of contact between capillaries and muscle fibres has been suggested to be the site of greatest oxygen flux density in the movement of oxygen from the capillaries to the muscle fibres. A new measurement of tissue capillarity, designed specifically for use on non-perfusion fixed muscle tissue (i.e., that obtained via needle biopsy) is presented that describes the capillary supply from this perspective. The Capillary-to-Fibre Perimeter Exchange Index (the CFPE Index) is derived as the quotient of the individual capillary-to-fibre ratio (i.e., the capillary-to-fibre ratio calculated for each fibre individually) and the fibre perimeter. This method is suggested to provide a means of quantitating potential alterations in the capacity for oxygen flux (e.g., as may occur in response to a training intervention) and any carrier- or receptor-mediated aspect of blood-tissue exchange between the capillaries and muscle fibres (e.g., insulin or glucose delivery). Key words: capillary supply, muscle fibres, oxygen flux, training, diabetes

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1139/h97-002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 93

Metadata

Authors
Hepple, R. T.
Venue
Canadian Journal of Applied Physiology
Published
1997-02-01
Volume
22
Issue
1
Pages
11-22
ISSN
1066-7814 (ISSN-L)
OpenAlex
W2074955121
Cited by
93
References
0
FWCI
2.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Measurement of Tissue Capillarity: The Capillary-to-Fibre Perimeter Exchange Index. https://app.cochat.ai/papers/10.1139/h97-002
The paper
Hepple, R. T. (1997). A New Measurement of Tissue Capillarity: The Capillary-to-Fibre Perimeter Exchange Index. Canadian Journal of Applied Physiology. https://doi.org/10.1139/h97-002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.