A New Measurement of Tissue Capillarity: The Capillary-to-Fibre Perimeter Exchange Index
The DOI matches its Crossref record.
Abstract
The surface area of contact between capillaries and muscle fibres has been suggested to be the site of greatest oxygen flux density in the movement of oxygen from the capillaries to the muscle fibres. A new measurement of tissue capillarity, designed specifically for use on non-perfusion fixed muscle tissue (i.e., that obtained via needle biopsy) is presented that describes the capillary supply from this perspective. The Capillary-to-Fibre Perimeter Exchange Index (the CFPE Index) is derived as the quotient of the individual capillary-to-fibre ratio (i.e., the capillary-to-fibre ratio calculated for each fibre individually) and the fibre perimeter. This method is suggested to provide a means of quantitating potential alterations in the capacity for oxygen flux (e.g., as may occur in response to a training intervention) and any carrier- or receptor-mediated aspect of blood-tissue exchange between the capillaries and muscle fibres (e.g., insulin or glucose delivery). Key words: capillary supply, muscle fibres, oxygen flux, training, diabetes
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(–)-Epicatechin enhances fatigue resistance and oxidative capacity in mouse muscle
Nogueira, L., Ramirez‐Sanchez, I., Perkins, G. A., Murphy, A., Taub, P. R., Ceballos, G., Villarreal, F. J., Hogan, M. C., & Malek, M. H. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.209924 · Cited by 205
Hepple, R. T., Mackinnon, S. L. M., Goodman, J. M., Thomas, S. G., & Plyley, M. J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1305 · Cited by 203
Self-citationCocks, M., Shaw, C. S., Shepherd, S. O., Fisher, J. P., Ranasinghe, A., Barker, T. A., & Wagenmakers, A. J. M. (2016) · The Journal of Physiology · doi:10.1113/jphysiol.2014.285254 · Cited by 117
“glucose and insulin) than traditional measures such as CD (Hepple, 1997).”
BackgroundGil, S., Kirwan, J. P., Murai, I. H., Dantas, W. S., Merege‐Filho, C. A. A., Ghosh, S., Shinjo, S. K., Pereira, R. M. R., Teodoro, W. R., Felau, S. M., et al. (2021) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12815 · Cited by 72
“The quantification of muscle fibre capillaries [capillary contacts (CC, the number of capillaries around a fibre), capillary-to-fibre ratio on an individual fibre basis (C/Fi), and capillary-to-fibre perimeter exchange index (CFPE, an estimate of the capillary-to-fibre surface area)] were performed on 50 muscle fibres…”
MethodHorwath, O., Apró, W., Moberg, M., Godhe, M., Helge, T., Ekblom, M., Hirschberg, A. L., & Ekblom, B. (2020) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00893.2019 · Cited by 70
“286 Quantification of fiber type-specific capillary indices was performed in accordance with 287 previous work (28), comprising capillary contacts (CC; number of capillaries in contact with 288 each individual fiber) and the capillary-to-fiber ratio (C/Fi; capillaries in contact with each 289 individual fiber consider…”
BackgroundMethod
Metadata
- Authors
- Hepple, R. T.
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 1997-02-01
- Volume
- 22
- Issue
- 1
- Pages
- 11-22
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2074955121
- Cited by
- 93
- References
- 0
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Measurement of Tissue Capillarity: The Capillary-to-Fibre Perimeter Exchange Index. https://app.cochat.ai/papers/10.1139/h97-002
- The paper
- Hepple, R. T. (1997). A New Measurement of Tissue Capillarity: The Capillary-to-Fibre Perimeter Exchange Index. Canadian Journal of Applied Physiology. https://doi.org/10.1139/h97-002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.