A PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Technological advances in robotic hardware and software have enabled powered exoskeletons to move from science fiction to the real world. The objective of this article is to emphasize two main points for future research. First, the design of future devices could be improved by exploiting biomechanical principles of animal locomotion. Two goals in exoskeleton research could particularly benefit from additional physiological perspective: (i) reduction in the metabolic energy expenditure of the user while wearing the device, and (ii) minimization of the power requirements for actuating the exoskeleton. Second, a reciprocal potential exists for robotic exoskeletons to advance our understanding of human locomotor physiology. Experimental data from humans walking and running with robotic exoskeletons could provide important insight into the metabolic cost of locomotion that is impossible to gain with other methods. Given the mutual benefits of collaboration, it is imperative that engineers and physiologists work together in future studies on robotic exoskeletons for human locomotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170 · cited 1×
“Researchers have used inverse dynamics analysis to design exoskeletons that approximate normal human joint kinematic and kinetic patterns.(21,22) Inverse dynamics analysis could be further employed to identify compensatory coordination strategies that increase the cost of locomotion with the exoskeleton.”
MethodIndependent metabolic costs of supporting body weight and accelerating body mass during walking
Grabowski, A., Farley, C. T., & Kram, R. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00734.2004 · Cited by 251
Energy expenditure while standing or walking slowly uphill or downhill with loads
PIMENTAL, N. A., & PANDOLF, K. B. (1979) · Ergonomics · doi:10.1080/00140137908924670 · Cited by 72
Cited by
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Self-citationBiorobotics: Using robots to emulate and investigate agile locomotion
Ijspeert, A. J. (2014) · Science · doi:10.1126/science.1254486 · Cited by 491
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
A lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
“In particular, considerable work has been conducted in the area of active exoskeletons for augmenting load carriage capacity [10-14].”
BackgroundMechanics and energetics of level walking with powered ankle exoskeletons
Sawicki, G. S., & Ferris, D. P. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.009241 · Cited by 297
Self-citationA pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
Self-citationPowered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
“For this information, the 2 J. Neural Eng. 13 (2016) 031001 Topical Review reader is directed to several published reviews surveying the state-of-the-art for lower-extremity powered exoskeletons (Ferris et al 2007, Dollar and Herr 2008, Pons 2008, Yang et al 2008, Bogue 2009, Herr 2009).”
BackgroundPowered Hip Exoskeletons Can Reduce the User's Hip and Ankle Muscle Activations During Walking
Lenzi, T., Carrozza, M. C., & Agrawal, S. K. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2248749 · Cited by 215
How adaptation, training, and customization contribute to benefits from exoskeleton assistance
Poggensee, K. L., & Collins, S. H. (2021) · Science Robotics · doi:10.1126/scirobotics.abf1078 · Cited by 214
“Metabolic cost is an important outcome in exoskeleton research (10) and other locomotion-based motor learning research (36,37).”
BackgroundAn Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
Tang, Z., Zhang, K., Sun, S., Gao, Z., Zhang, L., & Yang, Z. (2014) · Sensors · doi:10.3390/s140406677 · Cited by 182
“The advantages were: (1) it provided an effective way to control the exoskeleton in real time using biological signals [43]; (2) it led to a greater mechanical assistance to improve the power-assist effectiveness; and (3) the nervous system could easily adapt the exoskeleton control for different motions [40].”
BackgroundSawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179
“Instead, powering joints where active muscle rather than recoiling tendon performs most of the positive mechanical work (i.e. powering the less efficient joints) may lead to larger reductions in metabolic cost (Ferris et al., 2007).”
BackgroundSelf-citationSimulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads
Dembia, C. L., Silder, A., Uchida, T. K., Hicks, J. L., & Delp, S. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0180320 · Cited by 170
Metadata
- Authors
- FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A.
- Venue
- International Journal of Humanoid Robotics
- Publisher
- World Scientific Pub Co Pte Ltd
- Published
- 2007-09
- Volume
- 04
- Issue
- 03
- Pages
- 507-528
- ISSN
- 0219-8436 (ISSN-L)
- 1793-6942
- OpenAlex
- W2160060605
- Cited by
- 185
- References
- 3
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.