Mercury and freon: temperature emulation and management for server systems
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Power densities have been increasing rapidly at all levels of server systems. To counter the high temperatures resulting from these densities, systems researchers have recently started work on softwarebased thermal management. Unfortunately, research in this new area has been hindered by the limitations imposed by simulators and real measurements. In this paper, we introduce Mercury, a software suite that avoids these limitations by accurately emulating temperatures based on simple layout, hardware, and componentutilization data. Most importantly, Mercury runs the entire software stack natively, enables repeatable experiments, and allows the study of thermal emergencies without harming hardware reliability. We validate Mercury using real measurements and a widely used commercial simulator. We use Mercury to develop Freon, a system that manages thermal emergencies in a server cluster without unnecessary performance degradation. Mercury will soon become available from http://www.darklab.rutgers.edu.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Managing energy and server resources in hosting centers
Chase, J. S., Anderson, D. C., Thakar, P. N., Vahdat, A. M., & Doyle, R. P. (2001) · Proceedings of the eighteenth ACM symposium on Operating systems principles · doi:10.1145/502034.502045 · Cited by 1,284
Making scheduling cool: temperature-aware workload placement in data centers
Moore, J., Chase, J., Ranganathan, P., & Sharma, R. K. (2005) · USENIX Annual Technical Conference · Cited by 651
Managing server energy and operational costs in hosting centers
Chen, Y., Das, A., Qin, W., Sivasubramaniam, A., Wang, Q., & Gautam, N. (2005) · Proceedings of the 2005 ACM SIGMETRICS international conference on Measurement and modeling of computer systems · doi:10.1145/1064212.1064253 · Cited by 556
Balance of Power: Dynamic Thermal Management for Internet Data Centers
Sharma, R. K., Bash, C. E., Patel, C. D., Friedrich, R. J., & Chase, J. S. (2005) · IEEE Internet Computing · doi:10.1109/mic.2005.10 · Cited by 443
Gansner, E. R. (2006) · Cited by 350
Energy conservation in heterogeneous server clusters
Heath, T., Diniz, B., Carrera, E. V., Meira, W., & Bianchini, R. (2005) · Proceedings of the tenth ACM SIGPLAN symposium on Principles and practice of parallel programming · doi:10.1145/1065944.1065969 · Cited by 329
Self-citationWeatherman: Automated, Online and Predictive Thermal Mapping and Management for Data Centers
Moore, J., Chase, J. S., & Ranganathan, P. (2006) · 2006 IEEE International Conference on Autonomic Computing · doi:10.1109/icac.2006.1662394 · Cited by 205
A performance-conserving approach for reducing peak power consumption in server systems
Felter, W., Rajamani, K., Keller, T., & Rusu, C. (2005) · Proceedings of the 19th annual international conference on Supercomputing · doi:10.1145/1088149.1088188 · Cited by 196
Thermal Modeling, Characterization and Management of On-Chip Networks
Shang, L., Peh, L., Kumar, A., & Jha, N. K. (2005) · 37th International Symposium on Microarchitecture (MICRO-37'04) · doi:10.1109/micro.2004.35 · Cited by 181
Balancing power consumption in multiprocessor systems
Merkel, A., & Bellosa, F. (2006) · European Conference on Computer Systems · doi:10.1145/1217935.1217974 · Cited by 151
Cited by
Power provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · Proceedings of the 34th annual international symposium on Computer architecture · doi:10.1145/1250662.1250665 · Cited by 1,797
The Datacenter as a Computer: An Introduction to the Design of Warehouse-Scale Machines
Barroso, L. A., & Hölzle, U. (2009) · Synthesis lectures on computer architecture · doi:10.2200/s00193ed1v01y200905cac006 · Cited by 1,714
Power provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · ACM SIGARCH Computer Architecture News · doi:10.1145/1273440.1250665 · Cited by 662
VirtualPower: coordinated power management in virtualized enterprise systems
Nathuji, R., & Schwan, K. (2007) · Proceedings of twenty-first ACM SIGOPS symposium on Operating systems principles · doi:10.1145/1294261.1294287 · Cited by 606
Barroso, L. A., Clidaras, J., & Hölzle, U. (2013) · Synthesis lectures on computer architecture · doi:10.2200/s00516ed2v01y201306cac024 · Cited by 489
Tang, Q., Gupta, S. K. S., & Varsamopoulos, G. (2008) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2008.111 · Cited by 481
Benefits and limitations of tapping into stored energy for datacenters
Govindan, S., Sivasubramaniam, A., & Urgaonkar, B. (2011) · Proceedings of the 38th annual international symposium on Computer architecture · doi:10.1145/2000064.2000105 · Cited by 223
“There have been a number of control techniques to cap power using some kind of throttling [16,22,40,41,45] and workload shaping [17,34] temporally (moving the load over time to less critical points) and/or spatially (moving workloads across the datacenter).”
BackgroundGreen Cloud Computing and Environmental Sustainability
Kumar, S., & Buyya, R. (2012) · Harnessing Green It · doi:10.1002/9781118305393.ch16 · Cited by 211
“[40] proposed emulation tools for investigating the thermal implications of power management.”
BackgroundReducing electricity cost through virtual machine placement in high performance computing clouds
Le, K., Bianchini, R., Zhang, J., Jaluria, Y., Meng, J., & Nguyen, T. D. (2011) · Proceedings of 2011 International Conference for High Performance Computing, Networking, Storage and Analysis · doi:10.1145/2063384.2063413 · Cited by 199
“Prior work has considered two classes of thermal management policies for data centers: those that manage temperatures under normal operation [36, 37, 39, 48] and those that manage thermal emergencies [11, 17, 26, 45, 51].”
BackgroundSelf-citationExploiting Platform Heterogeneity for Power Efficient Data Centers
Nathuji, R., Isci, C., & Gorbatov, E. (2007) · Fourth International Conference on Autonomic Computing (ICAC'07) · doi:10.1109/icac.2007.16 · Cited by 191
“At the data center level, incorporating temperatureawareness into workload placement has been proposed by Moore et al. [17], along with emulation environments for studies of thermal implications of power management [ 10 ].”
BackgroundDejaVu: accelerating resource allocation in virtualized environments
Vasić, N., Novaković, D., Miučin, S., Kostić, D., & Bianchini, R. (2012) · Proceedings of the seventeenth international conference on Architectural Support for Programming Languages and Operating Systems · doi:10.1145/2150976.2151021 · Cited by 174
“Both an alytical modeling and experimentation have been proposed for evalua ting allocations in similar datacenter settings [10, 12, 14, 8, 30, 33, 36, 37, 40, 42, 43].”
Self-citation
Metadata
- Authors
- Heath, T., Centeno, A. P., George, P., Ramos, L., Jaluria, Y., & Bianchini, R.
- Venue
- Proceedings of the 12th international conference on Architectural support for programming languages and operating systems
- Publisher
- ACM
- Published
- 2006-10-20
- Pages
- 106-116
- OpenAlex
- W2150654762
- Cited by
- 199
- References
- 11
- FWCI
- 12.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.