Renewable and cooling aware workload management for sustainable data centers
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Recently, the demand for data center computing has surged, increasing the total energy footprint of data centers worldwide. Data centers typically comprise three subsystems: IT equipment provides services to customers; power infrastructure supports the IT and cooling equipment; and the cooling infrastructure removes heat generated by these subsystems. This work presents a novel approach to model the energy flows in a data center and optimize its operation. Traditionally, supply-side constraints such as energy or cooling availability were treated independently from IT workload management. This work reduces electricity cost and environmental impact using a holistic approach that integrates renewable supply, dynamic pricing, and cooling supply including chiller and outside air cooling, with IT workload planning to improve the overall sustainability of data center operations. Specifically, we first predict renewable energy as well as IT demand. Then we use these predictions to generate an IT workload management plan that schedules IT workload and allocates IT resources within a data center according to time varying power supply and cooling efficiency. We have implemented and evaluated our approach using traces from real data centers and production systems. The results demonstrate that our approach can reduce both the recurring power costs and the use of non-renewable energy by as much as 60% compared to existing techniques, while still meeting the Service Level Agreements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertsekas, D. P. (1997) · Journal of the Operational Research Society · doi:10.1038/sj.jors.2600425 · Cited by 11,726
Holman, J. P. (1976) · Cited by 9,157
(2011) · SpringerReference · doi:10.1007/springerreference_57547 · Cited by 3,190
Weik, M. H. (2000) · Computer Science and Communications Dictionary · doi:10.1007/1-4020-0613-6_12436 · Cited by 2,570
Power provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · Proceedings of the 34th annual international symposium on Computer architecture · doi:10.1145/1250662.1250665 · Cited by 1,797
Power management in energy harvesting sensor networks
Kansal, A., Hsu, J., Zahedi, S., & Srivastava, M. B. (2007) · ACM Transactions on Embedded Computing Systems · doi:10.1145/1274858.1274870 · Cited by 1,533
Vazirani, V. V. (2003) · Springer eBooks · doi:10.1007/978-3-662-04565-7 · Cited by 716
Making scheduling cool: temperature-aware workload placement in data centers
Moore, J., Chase, J., Ranganathan, P., & Sharma, R. K. (2005) · USENIX Annual Technical Conference · Cited by 651
No "power" struggles: coordinated multi-level power management for the data center
Raghavendra, R., Ranganathan, P., Talwar, V., Wang, Z., & Zhu, X. (2008) · Proceedings of the 13th international conference on Architectural support for programming languages and operating systems · doi:10.1145/1346281.1346289 · Cited by 619
Self-citationRao, L., Liu, X., Xie, L., & Liu, W. (2010) · 2010 Proceedings IEEE INFOCOM · doi:10.1109/infcom.2010.5461933 · Cited by 526
Cited by
Data Center Energy Consumption Modeling: A Survey
Dayarathna, M., Wen, Y., & Fan, R. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2481183 · Cited by 1,165
Habibi Khalaj, A., & Halgamuge, S. K. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.037 · Cited by 707
Resource Management in Clouds: Survey and Research Challenges
Jennings, B., & Stadler, R. (2015) · Journal of Network and Systems Management · doi:10.1007/s10922-014-9307-7 · Cited by 548
Zeng, D., Gu, L., Guo, S., Cheng, Z., & Yu, S. (2016) · IEEE Transactions on Computers · doi:10.1109/tc.2016.2536019 · Cited by 426
Huang, P., Copertaro, B., Zhang, X., Shen, J., Löfgren, I., Rönnelid, M., Fahlen, J., Andersson, D., & Svanfeldt, M. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114109 · Cited by 414
Carbon-aware computing for datacenters
Radovanović, A., Koningstein, R., Schneider, I., Chen, B., Duarte, A., Roy, B., Xiao, D., Haridasan, M., Hung, P., Care, N., et al. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3173250 · Cited by 353
“Research investigations for temporal shifting of flexible compute jobs proposed an optimization-based framework with stylized models for job-level resource demand modeling [25]–[27], and server-level power consumption.”
Zhang, Q., Meng, Z., Hong, X., Zhan, Y., Liu, J., Dong, J., Bai, T., Niu, J., & Deen, M. J. (2021) · Journal of Systems Architecture · doi:10.1016/j.sysarc.2021.102253 · Cited by 351
Energy efficiency and renewable energy integration in data centres. Strategies and modelling review
Oró, E., Depoorter, V., Garcia, A., & Salom, J. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.035 · Cited by 318
Smartly Handling Renewable Energy Instability in Supporting A Cloud Datacenter
Gao, J., Wang, H., & Shen, H. (2020) · 2020 IEEE International Parallel and Distributed Processing Symposium (IPDPS) · doi:10.1109/ipdps47924.2020.00084 · Cited by 272
Parasol and GreenSwitch: managing datacenters powered by renewable energy
Goiri, Í., Katsak, W., Le, K., Nguyen, T. D., & Bianchini, R. (2013) · Proceedings of the eighteenth international conference on Architectural support for programming languages and operating systems · doi:10.1145/2451116.2451123 · Cited by 236
Big Data Meet Green Challenges: Greening Big Data
Wu, J., Guo, S., Li, J., & Zeng, D. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2016.2550538 · Cited by 232
“In [99], Liu et al.”
Data center demand response: Avoiding the coincident peak via workload shifting and local generation
Liu, Z., Wierman, A., Chen, Y., Razon, B., & Chen, N. (2013) · Performance Evaluation · doi:10.1016/j.peva.2013.08.014 · Cited by 211
Self-citationOpportunities and challenges for data center demand response
Wierman, A., Liu, Z., Liu, I., & Mohsenian-Rad, H. (2014) · International Green Computing Conference · doi:10.1109/igcc.2014.7039172 · Cited by 194
Self-citationPricing data center demand response
Liu, Z., Liu, I., Low, S., & Wierman, A. (2014) · The 2014 ACM international conference on Measurement and modeling of computer systems · doi:10.1145/2591971.2592004 · Cited by 160
“This ratio can vary widely across data centers, but we choose this ratio as representative based on discussions in [35].”
MethodSelf-citationGreening Geographical Load Balancing
Liu, Z., Lin, M., Wierman, A., Low, S., & Andrew, L. L. H. (2015) · IEEE/ACM Transactions on Networking · doi:10.1109/tnet.2014.2308295 · Cited by 159
“F algorithms do not require centralizing information, they can be deployed where different parties (data centers, proxy routers) belong to different administration domains (or even different third-part companies) and sharing of data among them is difficult.”
BackgroundSelf-citationResource and Deadline-Aware Job Scheduling in Dynamic Hadoop Clusters
Cheng, D., Rao, J., Jiang, C., & Zhou, X. (2015) · 2015 IEEE International Parallel and Distributed Processing Symposium · doi:10.1109/ipdps.2015.36 · Cited by 61
“To pursue cost-efficiency, Hadoop clusters can be powered by a mix of renewable energy and traditional power grid [6], [9], [17], or share the same cloud infrastructure with interactive workloads [17], [23], or run opportunistically on transient resources, e.g., Amazon Spot Instances.”
Background(2018) · doi:10.1109/tcc.2016.2535201 · Cited by 39
“We measure the batch workloads in terms of machine-time, as considered widely in existing literature [25], [26] and can successfully guide dynamic provisioning of computing resources.”
MethodAdaptive Capacity Provisioning for Carbon-Aware Data Centers: A Digital Twin-Based Approach
Cao, Z., Wang, R., Zhou, X., Tan, R., Wen, Y., Yan, Y., & Wang, Z. (2025) · IEEE Transactions on Sustainable Computing · doi:10.1109/tsusc.2025.3526192 · Cited by 16
Self-citationOn the Carbon Footprint Optimization in an InterCloud Environment
Justafort, V. D., Beaubrun, R., & Pierre, S. (2018) · IEEE Transactions on Cloud Computing · doi:10.1109/tcc.2015.2511768 · Cited by 10
“[41] proposed a workload placement approach based on the available renewable energy sources and the cooling efficiency in order to minimize the operational cost of a data center.”
BackgroundA hybrid approach for optimizing carbon footprint in intercloud environment
Justafort, V. D., Beaubrun, R., & Pierre, S. (2019) · IEEE Transactions on Services Computing · doi:10.1109/tsc.2016.2638900 · Cited by 7
Metadata
- Authors
- Liu, Z., Chen, Y., Bash, C., Wierman, A., Gmach, D., Wang, Z., Marwah, M., & Hyser, C.
- Venue
- Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems
- Publisher
- ACM
- Published
- 2012-06-11
- Pages
- 175-186
- OpenAlex
- W2107128713
- Cited by
- 413
- References
- 26
- FWCI
- 40.68
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.