Advancing Muscle-Computer Interfaces with High-Density Electromyography
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
In this paper we present our results on using electromyographic (EMG) sensor arrays for finger gesture recognition. Sensing muscle activity allows to capture finger motion without placing sensors directly at the hand or fingers and thus may be used to build unobtrusive body-worn interfaces. We use an electrode array with 192 electrodes to record a high-density EMG of the upper forearm muscles. We present in detail a baseline system for gesture recognition on our dataset, using a naive Bayes classifier to discriminate the 27 gestures. We recorded 25 sessions from 5 subjects. We report an average accuracy of 90% for the within-session scenario, showing the feasibility of the EMG approach to discriminate a large number of subtle gestures. We analyze the effect of the number of used electrodes on the recognition performance and show the benefit of using high numbers of electrodes. Cross-session recognition typically suffers from electrode position changes from session to session. We present two methods to estimate the electrode shift between sessions based on a small amount of calibration data and compare it to a baseline system with no shift compensation. The presented methods raise the accuracy from 59% baseline accuracy to 75% accuracy after shift compensation. The dataset is publicly available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayward-Smith, V. J. (1991) · Journal of the Operational Research Society · doi:10.1057/jors.1991.155 · Cited by 16,821
Watersheds in digital spaces: an efficient algorithm based on immersion simulations
Vincent, L., & Soille, P. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.87344 · Cited by 5,649
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268 · cited 1×
“The RMS of an electromyogram has a high correlation to the force generated by the muscle and is therefore an adequate and widely used feature [6] for quantifying muscle activity.”
BackgroundO’Regan, G. (2023) · Texts in Computer Science · doi:10.1007/978-3-031-26212-8_4 · Cited by 1,614
The Optimality of Naive Bayes.
Zhang, H. (2004) · Cited by 1,550
Digits: freehand 3D interactions anywhere using a wrist-worn gloveless sensor
Kim, D., Hilliges, O., Izadi, S., Butler, A. D., Chen, J., Oikonomidis, I., & Olivier, P. (2012) · Proceedings of the 25th annual ACM symposium on User interface software and technology · doi:10.1145/2380116.2380139 · Cited by 428 · cited 1×
“This includes body-worn cameras [12, 19], wrist-worn depth cameras [9], measuring the movement of the tendons [14] or directly measuring the muscle activity via Electromyography (EMG) [2, 10, 16, 17, 22].”
MethodGestureWrist and GesturePad: unobtrusive wearable interaction devices
Rekimoto, J. (2002) · Proceedings Fifth International Symposium on Wearable Computers · doi:10.1109/iswc.2001.962092 · Cited by 410 · cited 3×
“This includes body-worn cameras [12, 19], wrist-worn depth cameras [9], measuring the movement of the tendons [14] or directly measuring the muscle activity via Electromyography (EMG) [2, 10, 16, 17, 22].”
BackgroundMethodWUW - wear Ur world: a wearable gestural interface
Mistry, P., Maes, P., & Chang, L. (2009) · CHI '09 Extended Abstracts on Human Factors in Computing Systems · doi:10.1145/1520340.1520626 · Cited by 372 · cited 1×
“This includes body-worn cameras [12, 19], wrist-worn depth cameras [9], measuring the movement of the tendons [14] or directly measuring the muscle activity via Electromyography (EMG) [2, 10, 16, 17, 22].”
MethodAnalysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350 · cited 3×
“For the GMM method, gestures 11, 14, 23, and 24 lead to highest accuracies with 11 performing best.”
MethodResultMuceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275 · cited 7×
“This includes body-worn cameras [12, 19], wrist-worn depth cameras [9], measuring the movement of the tendons [14] or directly measuring the muscle activity via Electromyography (EMG) [2, 10, 16, 17, 22].”
BackgroundMethodResultInfluentialStarner, T., Auxier, J., Ashbrook, D., & Gandy, M. (2002) · Digest of Papers. Fourth International Symposium on Wearable Computers · doi:10.1109/iswc.2000.888469 · Cited by 267 · cited 3×
“The same applies for gestures 19 and 20, which are also frequently confused.”
BackgroundMethodEMG-based hand gesture recognition for realtime biosignal interfacing
Kim, J., Mastnik, S., & André, E. (2008) · Proceedings of the 13th international conference on Intelligent user interfaces · doi:10.1145/1378773.1378778 · Cited by 220 · cited 3×
“This includes body-worn cameras [12, 19], wrist-worn depth cameras [9], measuring the movement of the tendons [14] or directly measuring the muscle activity via Electromyography (EMG) [2, 10, 16, 17, 22].”
BackgroundMethodAng, K. K., Chin, Z. Y., Zhang, H., & Guan, C. (2012) · Pattern Recognition · doi:10.1016/j.patcog.2011.04.018 · Cited by 205 · cited 1×
“A detailed description of this algorithm can be found in [1].”
BackgroundHigh-density surface EMG maps from upper-arm and forearm muscles
Rojas-Martínez, M., Mañanas, M. A., & Alonso, J. F. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-85 · Cited by 181
Multi-subject/daily-life activity EMG-based control of mechanical hands
Castellini, C., Fiorilla, A. E., & Sandini, G. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-41 · Cited by 155
Making muscle-computer interfaces more practical
Saponas, T. S., Tan, D. S., Morris, D., Turner, J., & Landay, J. A. (2010) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753451 · Cited by 141 · cited 6×
“In a follow-up work Saponas et al. [18] use a wireless armband and investigate performance under realistic conditions including cross-session evaluation on different days.”
BackgroundInfluentialGesture-based control and EMG decomposition
Wheeler, K., Chang, M. H., & Knuth, K. H. (2006) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2006.875418 · Cited by 81
Hand gesture recognition based on surface electromyography
Samadani, A.-A., & Kulić, D. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944549 · Cited by 51 · cited 3×
“This includes body-worn cameras [12, 19], wrist-worn depth cameras [9], measuring the movement of the tendons [14] or directly measuring the muscle activity via Electromyography (EMG) [2, 10, 16, 17, 22].”
BackgroundMethod
Cited by
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680
Gesture recognition by instantaneous surface EMG images
Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., & Li, J. (2016) · Scientific Reports · doi:10.1038/srep36571 · Cited by 595
A novel attention-based hybrid CNN-RNN architecture for sEMG-based gesture recognition
Hu, Y., Wong, Y., Wei, W., Du, Y., Kankanhalli, M., & Geng, W. (2018) · PLOS ONE · doi:10.1371/journal.pone.0206049 · Cited by 398
Deep Learning for EMG-based Human-Machine Interaction: A Review
Xiong, D., Zhang, D., Zhao, X., & Zhao, Y. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1003865 · Cited by 395
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Metadata
- Authors
- Amma, C., Krings, T., Böer, J., & Schultz, T.
- Venue
- Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems
- Publisher
- ACM
- Published
- 2015-04-18
- Pages
- 929-938
- OpenAlex
- W2004931716
- Cited by
- 168
- References
- 19
- FWCI
- 21.67
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.